Loading...
HomeMy WebLinkAboutEngineered Plan - 2018PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE TOP FOUND. EL. 46.9' SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 43.8-44.8' MINIMUM 1.75' OF COVER OVER PRECA6 2% SLOPE REQUIRED OVER SYSTEM 41.8' PRECAST H-�o NOTE: 2" MIN. WALL BLOCKS OR ' RISERS H-1 THICKNESS REQUIRED 42 S' PRECAST RISERS 2'0 4"OSCH40 PVC MORTAR ALL H-10 ' 6" MIN. SUMP PIPES LEVEL 1 ST 2' COMPONENTS , ° 12" MIN. INT. DIM. 4' (TYP.) INV S EL. 38.2 4' A ENDS SIDES 39.03' 10" 1500 GAL H-10 14" p °O°°o°°° - 000000°o° 41.74' TEE SEPTIC TANK TEE 41.49' o�oa PIF ooao aoo 'o°o°o°o° °000°o°oo°°° WATERTEST D'BOX >00000000o�aoa000a�� ®®®oaa�o®®® ° ° ° ° o ° ° ° ° ° o ° ° GAS BAFFLE o 0 0 0 0 0 '00000000 o 0 0 0 aoaoaoao�oo o�o����oo�� ° ° ° ° -o0o0o„000_ FOR LEVELNESS c�io° ° ° ° >0000000ooa000a0000 a00000aoaoo .00000000 , 38 53' 38 37 'O°°°°°°° 36.2 •: 99— 99— :: 4 LIQ. LEVEL (ACME OR EQUAL) .:; X 99. ' EXIST. SPOT ELEV. —[99]— ° ° ° ° 198•41 •D00 ODODOO°0°0000000000000000000000000000 TEST HOLE 2�. SLOPE OF GROUND 0; °0000000o�o�°°�°00000000�o�o�o�°�°„°�00000. H-10 500 GAL. 3/4"-1-1/2" DOUBLE WASHED STONE X' MIN. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING a, (2) UNITS REQUIRED 6 ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' Locus 1 COMPACTION. (15.221 [2]) o � on ysid � 1n *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS Dennis PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM Pond ( 1 1.5 y, SLOPE) ( 8 %SLOPE) (-L-7. SLOPE) 30.7' BOTTOM TH-1 NO GROUNDWATER FOUND FOUNDATION— 19' SEPTIC TANK 37' D' LEACHING BOX 17' FACILITY "f B_.ND GEGEN D- 99— 99— EXISTING CONTOUR X 99. ' EXIST. SPOT ELEV. —[99]— PROPOSED CONTOUR 198•41 PROPOSED SPOT EL. TH 1 TEST HOLE 2�. SLOPE OF GROUND <C21 UTILITY POLE - , FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: AMY VON HONE, RS DATE: 2/28/2018 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 0" 41.7' A LS 16" 10YR 2/2 B LS 30" 1OYR 5/6 39.2' C PERC MS 1OYR 7/6 132" 30.7' NO GROUNDWATER ENCOUNTERED DCE #18-036 Scale: 1"= 20' 0 10 20 30 40 50 FEET NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -M 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR. SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. DATE LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 113 PARCEL 22 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001 CO578J DATED 7/16/2014 Yarmouth HeJ" th Dqwirtriernt kP?RO D 6 6l6" )ante SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2),500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF DANIEL A. OJALA, P.E., P.L.S. 39 SUMMER STREET YARMOUTHPORT. MA PREPARED FOR JESSE HAGOPIAN DATE: MARCH 2, 2018 off 508-362-4541 fax 508-362-9880 downcape.com down cage entineering, inc. civil engineers /and surveyors 1 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 18-036 HAGOPIAN.DWG a 0 i o Tho � Z <C21 � ac o a, QI 6 Locus o � on ysid � Dennis Pond LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 113 PARCEL 22 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001 CO578J DATED 7/16/2014 Yarmouth HeJ" th Dqwirtriernt kP?RO D 6 6l6" )ante SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2),500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF DANIEL A. OJALA, P.E., P.L.S. 39 SUMMER STREET YARMOUTHPORT. MA PREPARED FOR JESSE HAGOPIAN DATE: MARCH 2, 2018 off 508-362-4541 fax 508-362-9880 downcape.com down cage entineering, inc. civil engineers /and surveyors 1 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 18-036 HAGOPIAN.DWG