Loading...
HomeMy WebLinkAboutBLD-99-000349 (15 Tern Road)TYPICAL TRIM: 1 X 8 FACIA 1 X & PLANCH W/CONT. VEI 1 X 8 FRIEZE I 1 1 /4 BED K 1 X 5 CORNEF 5OARD5 (TY 1 X O RAKE5 X 2 MOULD. (T 1 X 5 CORNI BOARDS (T) RIDGE VENTS @ VAULTED 12" 9" F (-v 4- I U I ht WtA I HtK A5 PER SPECS. AS PER SPECS. FRONT ELEVATION ASPHALT ROOF 5HINGLE5 TYPICAL TRIM: 1 X 8 FACIA 1 X 8 FLANCHER W/CONT. VENT 1 X 8 FRIEZE 5D. W/ \ 1 X O RAKE5 W11 1 1/4 SED MOULD. X 2 MOULD. (TY?.) 1 X 5 CORNER 50ARD5 (TYP.) 1 X O RAKE5 W11 X 2 MOULD. (T-(F.WHITE CEDAR SHINGLES \ WHITE CEDAR SHINGLES @ 5" TO THE WEATHER 1 X 5 CORNER 1 X 5 CORNER 1 X 5 CORNER B0ARD5 (TYF.) WHITE CEDAR BOARDS (T -YF.) 130ARD5 (TYF.) SHINGLES BRICK STEP A5 FER 5FEC5. REAR ELEVATION T012 OVERVIEW NOT TO SCALE WOW. TYFE 51ZE ROUGH OPENING I DOU-ff LE HUNG 2446 2'-6 1 /8" X 4'-9 1/4" 2 DOUBLE HUNG 2432 2'-6 10' X 3'-5 1/4" 3 CASEMENT CN235 3'-5 1/4" X 3'-5 3/8" 4 VELUX SKYLIGHT V5-308 30 1/2" X 55 1/2" 5 PICTURE 4446 4'-6 1 /8" X 4'-9 1/4" 6 DOUBLE HUNG 2046 2'-2 1 /8" X 4'-9 1/41t 7 1/2 ROUND CTN28-2 5'-7 7/8" X 3'-0 1/2" 8 VELUX SKYLIGHT F5-308 30 1/2" X 55 1/211 ANDERSEN ROUGH OFNGS., VERIFY ALL MEAS. IN FIELD DRS. TYPE 51ZE ROUGH OPENING A PATIO DR. FW H6068 6'-0" X 6'-8" B 9 LITE STL. DR. 3'-0" X 6'-8" 3'-2 1/2" X 6'-10 1/2" C 5TL. FIRE DR. 2'-8" X 6'-8" 2'-10 1/2" X 6'-10 1/2" D 6 PANEL MA5. 2'-6" X 6'-6" 2'-8 1/2" X 6'-8 1/2" E 6 PANEL MA5. 2'-4" X 6'-6" 2'-6 1/2" X 6-8 1/2" F 6 PANEL MAS. V-4" X 6'-6" 1'-6 1/2'(X 6'-8 1/2" G SLIDER FWG6068 6'-0" X 6'-8" H INT. BI -FOLD 5'-0" X 6'-6" 5'-2 1/2'(X 6-9 1/2'( 1 PULL DOWN EXCEL 8'-9" 25 1/2" X 54" J 6 FNL. STL. DR. 3'-0" X 6'-8" 3'-2 1/2'(X 6'-10 1/2" r TYPICAL TRIM: ASPHALT ROOF SHINGLES 1 X 8 FACIA 1 X 8 PLANCHER W/CONT. VENT 1 X 8 FRIEZE BD. W/ V5 -3O8- 1 1/4 BED MOULD. El 1 X 5 CORNER BOARDS (TY1'.) 1 X 6 RAKES W/ 1 X 2 MOULD. (TYP. 1 X 5 CORNER WHITE CEDAR SHINGLES BOARDS (TY?.) @ 5" TO THE WEATHER RIDGE VENTS @ VAULTED 12" 9" 1 X 6 RAKES W/ 1 X 2 MOULD. (Tri'.) ® WHITE CEDAR SHINGLES @ 5" TO THE WEATHER 1 X 5 CORNER BOARDS (TYP.) LEFT ELEVATION ASPHALT ROOF SHINGLES WHITE CEDAR SHINGLES BILCO "C" 12" 4.. ASPHALT KOOF A5 PER SPECS. A5 PER 5PEC5. KIGHT ELEVATION Lot 15 Tern P CORNER .D5 (TYP.) 8' 60' i 16'4 63 3/4 4'6 1/2 97 3/4 a M N JillN R.O.42" W X W 5/8" HX231/2"D 2'11 1/2 3' 4'1 3' 0 8' 16' 1235 TOTAL S.F. LIV. AREA, 208 S.F. PORCH, 336 S.F. GAR. & 485 S.F. FUTURE MOTHER IN LAW APT. FIK5T FL00K FLAN 1235 S.F. LIV. AREA U SMOKE s� SMOKE f PHOTO E O 1'10)7-3'10� 12' I Lot 15 Tern Road, 5. Yarmouth Scale: 1/4" = 1 '-O" I���� REALTY �Td. prawn by: Date: 11/ 1 1 /99 George Ruooao FIK5T FLOOR PLAN A3 OF 5 mm 10" 50NA-TUB FTG5. @ 48" BELOW OKAPE DBLE KIM J5T5.W/ METAL HANGERS ABOVE OPNG. I I COVERED FORCH A50VE BM. FKT. II II I° 8" X 7'-6" WALL -5 ON 16" X &" GONG. SPREAD FTGS. cr TF.) i 16' — 9'4 7' 12' 7' 17'8 17 a ° I I �.------BM.PKT.---------1 N I 12' N 14' 3 1/2" COL. ON 30" X 30" X 10" I 5D SMOKE DETECTOfZ (� GONG. FTG5. (TYP.) i O OqSMOKE DETECTOR N Irl —� IPHOTO ELECTKIC (3) 2 X 12 WD. 2, 2 X 10 FUZ. J5T5. 0 GIRD. (TYP.) @ 16" O.C. ABOVE \ ( i0 NOTE: DBLE J5T5. @ PARTITIONS RUNNING a I I I PARALLEL TO J5T5. & GABLE RIM JST5. OK USE S\ I MORIN CEDAR WIND5. W/ O.C. FOK FLUME NGIACCESS (TYP.) 4 \ a DBLE KIM J5T. ABOVE mr.) N \ 3 1/2" COLON 30" X 30" X 10" GONG. FTG5. (TYP.) I t� (3) 2 X 12 WD. — GKD. M.) BM. PKT. I BM. PKT. LLl — — — — — — — - -- 4'8 5'6 5' —51— 5' S'6 d I I 8" X 7'-6" GONG FOUND. o Q WALLS ON 16" X 9" CONC. -� � �o I I SPREAD FTG5. (TYP.) I i 0 4° CONC. FLP- OVER FULL BASEMENT o b p COMFACTED SOILS x N � N I I I I 67 6'6 N 6°6 `kms 6'6 ti. 616-- 6'6 AI I I I I GARAGE i I I 13'4 x 22'8 ° (3) 2 X 12 V,0. SD y 0 30" X 30" X 10" GONG. FTG5. (T`ff'.) cn O N tz Ci Ci O x LL. O p N NOTE: p x �N 0 ° DKOF 21 " FOR I I I d STEP FTG. I I IL I 1'6'J\- 4' SPACE „ 015T5 IN TH15 N v AREA C 12" O.C. 8" X 7'-6" GONG. FOUND. WALLS ON 16" X 9" CONG SPREAD FIGS. (Tr?.)7Z — — — — J ° n 14' .• FOUNDATION FLAN firtyll II II PROF 16" FOK OVKHD. DR. °I — IJ 2 2'7 r I 12" 2 X 12 RIDGE (TYP.) 9 2 X 6 COLLAR TIES @ 16" O.C. ASPHALT ROOF 1 " VENT HOLES R-38 IN5UL INS / @ CLOSED BAY5 15# FELT (1l1'.) T GLG5. (TYP.) 1/2" PLrWD. (TYP.) SKYLIGHT 2 X 10 RAFTERS _ 2 X 10 i;AFTEizS @ 16" O.C. (T)P.) \DOLT TIES BETWEEN (2) 2 X 8 WALL TIE 5M. @ 16" O.C. 10'-0" FKOM FLK. , WPAP K-30 IN5UL IN 2 RAFTERS EA END 5LOPE5 (1-(F.)& PLASTER (T)P. X 3) TYPAK HOUSE I r 1/2" PLYND. � LIV. RM. � DSU. KM. R-1 1 IN5UL 3/4" T& G PLYWD. 2 X 4 STUDS TO BE GLUED (TYP.) @ 16" O.C. (TYP.) \ P.T. 2 X 6 W/(3) 2 X 12 \ \ 2 X 10 FLK. J5T5. SEAL SILL K-19 INSUL, WD. GIRD. @ 16" O.C. (TW.) DAMP PROOF DAMP PROOF � (gyp.) BELOW GRADE BELOW GRADE LALL8' X 7'-6" CONC. BSM'T. 3 1/2" -fF.) B�JM'T• 8' X 7'-6" CONG. Gam' (') -FOUND. WALLS FOUND. WALL5 - 4" GONG. FLiZ OVER �\ COMPACTED 501L \ 16" X 9" GONG. FTG5. \ 30" X 30" X 10" GONG. W/KEYWAY (TW.) C•� : , � OL FTGS."(T)" 5I✓CTION t 1 CK055 5ECTION 12" , CK055 5ECTION 12" 2 X 12 KIDGE (TYP.) 9., ASPHALT ROOF 1 X 6 COLLAR TIE5 ® 48" O.C. 15# FELT (TYP.) 1 " VENT HOLES TO @ CLOSED BAYS EXTEND STUDS RAFTER FOR SUPP. 1/2" PLYWD. (1-YK) SKYLIGHT R-3& IN5UL. IN VAULTED CLC -7.0 FLAT 0-G5' (T'Yl'') 2 X 10 RAFTERS 2 X 10 RAFTF-K5 12'-O" FiZOM FLK. 0000000000000 _ 0 16" O.C. (T1rP.) @ 16" O.C. (TY1'•) \R-30 INSUL IN TY?rR HOUSE 5LOPE5 (rn'•) 2 X 8 CLG. J5T5. �TY1'AR HOUSE @ 16" O.C. (TYP.) WRAP v�" Ap, (TW.) 1/2" PLYWD. 'I N r < (�)PLYWD. ( ) - M. BED12M. BEPRM. 2. d R-1 1 INSUL K-1 1 IN5UL 3/4" T & G PLYND. 'TOBEp� , 2X4 STUDS 2 X 4 5;J'5 _ 'i ( ) ^; 'r @ 16" O.G. (11 P.) 16" O.C, p?.) u;i�ttii(;uu�ilUilt��U�IluiuTiitkuilrl�Jl�J11111�;1111N�S11(10(111;11TOi11i�ilJlll,�Uillll�fllillUU711�1 \ P.T. 2 X 6 W/ (3) 2 X 12 \ SEAL SILL WD GIRD 2 X 10 FLK. J5T5. R-19 IN5UL DAjk)v PROOF @ 16" O.C. (T)'P.) (np) DAMP PROOF E=' 0,'] GRADE BELOW OKADE 8' X 7'-5" CONC. BcJM�-(-. 3 1/2" yl.) GOLS. (TY1- 8'X 7'-6" CONC. FOUND. WALLS FOUND. WALLS �) 4" CONC. FLK. OVER (m'•) COMPACTED SOIL 16" X 9" GONG. FTG5. 30" X 30" X 10" GONG. W/KEYWAY (T -r?.) COL FTG5. (Tri'.) CK055 5ECTION j sono tubes, forms, etc. wiil be inspected before back filling. I� JOIST HANGER INSTALLATIONF WILL NOT BE APPROVED UNLESS MANUFACTURER'S NAILS ARE USED This plan must be on site with the permit and the Licensed Construction supervisor must be present for all inspections, 24 Hour notice Minimum, j with call back fee. TOWN OF YARMOUTH PHOTO -ELECTRIC TY'E SMOKE DETECTORSARE REQUIRED BY MASS. STATE BLDG: -CODE INSIDE AND OUTSIDE OF ALL BEDROOMS WITHIN 20' OF A KITCHEN OR BATH. ALL DETECTORS MUST `HAVE BATTERY BACK-UP TOWN OF YARMOUTH REVIEWED FOR BUILDING AND ZONING CODE COMPLI- ANCE. ERRORS OR OMMISSIONS DO NOT RELIEVE THE APPLICANT FROM THE RESPONSIBILITY OF 'AS BUILT' COMPLIANCE. DATE: // /1 7,9 BUILDt G OFFICIAL FILE, CCrfl"