HomeMy WebLinkAboutEngineered Plan - 2007SOIL TEST PIT DATA: DATE: 4/11/07 TEST BY: THE BSC GROUP, INC. WITNESSED BY: AMY VON HONE PERC. RATE: 2 MIN./INCH SOIL EVALUATOR MARK DIBB SOIL CLASS: 1 L.T.A.R. 0.74 G.P.D./SQ.FT. TEST PIT #1 GRD. EL. 77.0 EST. HIGH GW. 67.0 60" MEDIUM SAND 1OYR 7/4 NO G.W. APRIL 11, 2007 SEPTIC TANK DETAIL: 1,500 GALLON 1 i NOT TO SCALE NOTES: 1. SEPTIC TANK SHALL BE STEEL 5. INLET AND OUTLET TEES TO BE CAST IRON, REINFORCED CONCRETE. SCHED. 40 PVC OR CAST -IN-PLACE CONCRETE. TEES TO BE CENTERED UNDER MANHOLE COVER. 2. SEPTIC TANK TO WITHSTAND H-10 LOADING HIGH GROUNDWATER COMPUTATION UNLESS UNDER PAVEMENT, DRIVES OR BASED ON TP#1 TRAVELED WAYS, WHEREIN H-20 LOADING SHALL APPLY. 3. ALL PIPE CONNECTIONS AND CONCRETE lot DEPTH TO BOTTOM OF HOLE 10.0' 2-24" DIA CONCRETE MANHOLES - -- CONSTRUCTION SHALL BE WATERTIGHT FIN 0" EL = 67.0 - ' 1 INDICATES y_ ESTIMATED SEASONAL HIGH GROUND WATER INDICATES OBSERVED GROUND WATER RR INDICATES PERC. TEST INDICATES UNSUITABLE MATERIAL W/ METAL HANDLES BROUGHT 4. FILL ALL UNUSED KNOCKOUTS WITH TO 6" OF FINISH GRADE MORTAR. TEE TO BE UNDER 12" MIN. M.H. OPENING COVER RAISE M.H W/ 6" SEWER BRICK 10'-0" & MORTAR „ NORMAL WATER LEVEL 12 Icy- L 3" PRECAST SEPTIC TANK 10" 14" INLET TEE 5'-2" PLAN VIEW DISTRIBUTION BOX DETAIL: NOT TO SCALE NO. OF OUTLETS 5 FINISHED GRADE REMOVABLE2" CONCRETE COVER i LOAMY SAND WALLS 10YR42 1� B LOAMY SAND WITHIN 6" OF GRADE 1 4/6 2• EL = 75.0 2 60" MEDIUM SAND 1OYR 7/4 NO G.W. APRIL 11, 2007 SEPTIC TANK DETAIL: 1,500 GALLON 1 i NOT TO SCALE NOTES: 1. SEPTIC TANK SHALL BE STEEL 5. INLET AND OUTLET TEES TO BE CAST IRON, REINFORCED CONCRETE. SCHED. 40 PVC OR CAST -IN-PLACE CONCRETE. TEES TO BE CENTERED UNDER MANHOLE COVER. 2. SEPTIC TANK TO WITHSTAND H-10 LOADING HIGH GROUNDWATER COMPUTATION UNLESS UNDER PAVEMENT, DRIVES OR BASED ON TP#1 TRAVELED WAYS, WHEREIN H-20 LOADING SHALL APPLY. 3. ALL PIPE CONNECTIONS AND CONCRETE lot DEPTH TO BOTTOM OF HOLE 10.0' 2-24" DIA CONCRETE MANHOLES - -- CONSTRUCTION SHALL BE WATERTIGHT FIN 0" EL = 67.0 - ' 1 INDICATES y_ ESTIMATED SEASONAL HIGH GROUND WATER INDICATES OBSERVED GROUND WATER RR INDICATES PERC. TEST INDICATES UNSUITABLE MATERIAL W/ METAL HANDLES BROUGHT 4. FILL ALL UNUSED KNOCKOUTS WITH TO 6" OF FINISH GRADE MORTAR. TEE TO BE UNDER 12" MIN. M.H. OPENING COVER RAISE M.H W/ 6" SEWER BRICK 10'-0" & MORTAR „ NORMAL WATER LEVEL 12 Icy- L 3" PRECAST SEPTIC TANK 10" 14" INLET TEE 5'-2" PLAN VIEW DISTRIBUTION BOX DETAIL: NOT TO SCALE NO. OF OUTLETS 5 FINISHED GRADE REMOVABLE2" CONCRETE COVER TO WALLS NOTES: COVER � ; WITHIN 6" OF GRADE 2• LOAM 1. DIST. BOX TO WITHSTAND H-10 LOADING DISTURBED AREAS I -r- 'j- UNLESS UNDER PAVEMENT, DRIVES OR TRAVELED WAYS WHEREIN H-20 LOADING COMPACTED FI L 36" MAXIMUM,12"MINIMUM 15" SHALL APPLY. 6» 5, 5" OUTLETS + 8" 2. PROVIDE INLET TEE OR BAFFLE WHERE 3" LAYER SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR Q 0 IN PUMPED SYSTEM 30`b�C r�G e o oe o 4 00 0 oea `boC T ��' ���� �a°"`� 2" 3. FIRST TWO FEET OF PIPE OUT OF DIST. 4' BOTTOM ON LEVEL STABLE BASE 6" MIN. 3/4" TO BOX TO BE LAID LEVEL. CROSS-SECTION 1 1/2" CRUSHED 4. ALL PIPE CONNECTIONS AND CONCRETE STONE BASE CONSTRUCTION SHALL BE WATERTIGHT. 5'-1" 4 -0 MIN. ounceD ON 5'-8„ 15 1/2" Z LIQUID DEPTH (GAS oONIRa.) �- 5'-8" 1 N r' 6" MIN. 3/4' TO 1 1/2" STONE BOTTOM ON LEVEL STABLE BASE CROSS-SECTION VIEW 30 1/2" PRECAST DIST. BOX 171/-2. PLAN VIEW 5. FILL ALL UNUSED KNOCKOUTS WITH MORTAR j LEACHING DETAIL: NOT TO SCALE 3 -' 4" PVC 4.0' PIPE 0°°° 0 00 000 0,00 0 00 0000 0 00 0 0 0 0 000 00 0 0 00 00 0 00 00 0 0 00000000 o T 0 500 GALL LEAC TNG DRYWELLS o0 1 0 0 - O O °° 56" 84" 00 o° ° 10 0 0 00 00 0 000 0 00 01000,V00 00 000 00 00 0 0 0° 0 0 0 0 In 0 0 0 0 0 0 0° 0 0 0 0 0 0°° 0 0 O 0° 40.0' PROFILE: NOT TO SCALE 1 DATUM:I 0OFA/gS EL.=A VERTICAL DATUM: ASSUMED ��' I o�� MARK D.S9c�N i DESIGN CRITERIA: TOP FOUNDATION FIRST PIPE LENGTH 1 i I DIBB CONCRETE COVERS TO WITHIN7TO BE SET LEVEL BENCH MARK SET: HYDRANT TAG BOLT EL.= 78.3 6" OF FINISHED GRADE. FOR MIN. 2' i / 0 CIVIL � I DESIGN FLOW: ' / tlo' 4: " 7 3 110 330 FINISH � ELEVATION 80.10 � � ^ / � ��, A F; BEDROOMS AT G.P.B./D G.P.D. CLEANOUT 4" PVC SCH 40 scH 40 4 PVC scH 40LEACHING OCHoAM�BERG /�9REQUIRED SEPTIC TANK: 25' 25' 10 0 0 0 0 BENCHMARK / I =B I=D 1=G 0 0 0 Co 0 0 0 0 0 0 i HYDRANT TAG BOLT I / y� y/LO, j = I v 330 X 200% 660 GAL. I=C I=E H ELEV 80.10 ASSUMED / �/ I SEPTIC TANK PROVIDED: = 1500 GAL. 5 OUTLET 1=F //' SEPTIC TANK DIST. BOX 5.1 SEPARATION ; J EST. HIGH GROUNDWATER ` , i <4� U-)� �j 1_"1i I SIZE OF LEACHING FACILITY REQUIRED. DESIGN PERC. RATE: <2 MIN./ INCH �?SoO LONG TERM APPL. RATE 0.74 G.P.D/S.F. O M \N /�� / �/ / I INVERT ELEVATIONS: ��� �� 13' �' TWO RISERS // I 330 GPD 0,74 GPD/SF = 446 S.F. " / \ E � / 5 TO WITHIN 6 OF GRADE / \ TOP OF FOUNDATION 79.30 A �� \ J SIZE OF LEACHING FACILITY PROVIDED: .> / 1/ / 4 INVERT AT BUILDING 75.35 B REPLUMB EXISTING USE C4> 500 GALLON C❑NC, 4" INVERT AT SEPTIC TANK (IN) 74.85 C OI1 LEACHING CHAMBERS 7'X2'X40' / " 74.60 D / TP#1 �. / / / 1500 GALLON 4 INVERT AT SEPTIC TANK (OUT) �� P I / $� �/ / SEPTIC TANK \ I 4" INVERT AT DIST. BOX (IN) 74.37 E ��� \0,01 I �7 / /� ^/J/ / \ �'' I SIDEWALL-= 2C7+40') X 2' = 188 " 74.20 F �' \ � �\ 1.-,(�S�C y/ % / / \ 1 BOTTOM 7' X 40' = 280 4 INVERT AT DIST. BOX (OUT) \ P /// ��,� / /� r7��/ �\ I 468S.F. .000 <a 68 S,1- x 0,74 Gr D/SF = 34 6 G P D - .., ($J a D BOX �' r INVERTS AT LEACHING FACILITY: �+ / ,� c�2 /// j < (S� \ / / i ♦ �i /10.0 \ 1 4 INVERT AT LEACHING CHAMBER 74.1 G BREAKOUT 74.6 /! 1 �\ BOTTOM OF LEACHING CHAMBER 72.1 H i \ ��� /� / �f PROPOSED _ _ / � 7X40 S.A.S. 10.0 ADJUSTED GROUNDWATER �� / I? / BOTTOM OF HOLE 67.0 J O S EXISTING 1983 S.A.S TO REMAIN WG Z LOCUS INFORMATION VARIANCES REQUESTED: �� Al / \ \ �� '. / CURRENT OWNER: HARRIETT L. SUTHERLAND, TR TITLE V: SECTION 15.211: (1) TO ALLOW LEACHING SYSTEM TO BE 5' OFF O G BASE. .� TITLE REFERENCE: DEED BOOK 8561, PAGE 80 THE FRONT PROPERTY LINE IN LIEU OF 10'. EXIST. -INV =72.4��% / h, PLAN REFERENCE: PLAN BOOK 95, PAGE 41 EXISTING REPLUMB " 0. - -- OHW ASSESSORS MAP: 60 \ O / INTERIOR �� I _._----- OHW OH TITLE V: SECTION 15.211: (1) TO ALLOW SEWER LINE EXITING BUILDING TO BE I ��, \ ;A, 1 STORY �` OHw PARCEL: 51 \ o �' WOOD DWELLING TO INV -75.35 W 4' FROM WATER LINE IN LIEU OF 10'. I \ \ -c>r GAS EXISTING I � ZONING DISTRICT: R-40 i 1 A \ O O�` FF=80.3 EXIST. INV r TOF=79.3 =77.4 MEJER CONCRETE SETBACKS: FRONT 30' I \ 4i 6 -6 FULL / / DRIVE SIDE 20 / ' REAR 20 I < \ < < :FOUNDATION 1 m % // � � li,� �/� o -.4\ x`-80 i MINIMUM LOT SIZE: 40,000 S.F. LP/ \ O \s EXIST. INV y,� ��l \ \ \ =77.3//�� 1 �� EXISTING LOT AREA: 11,832t S.F. FLOOR PLAN \ \ p OVERLAY DISTRICT: APD \ �O \ O SEASONAL �v �r1'� - \ 'O/ PORCH NITROGEN SENSITIVE \ OT\ CONCRETE �EXISTING / ON SLAB // C; ((��� �� ,�� / ao ZONE: YES - ZONE II \ v\ <� DRIVEWAYS FEMA FLOOD BEDROOM LIVING ROOM/<\\ �' > ,\gr /� O, ZONE DISTRICT: "C" 6/17/86 GREAT ROOM 8 i #2 DINING 4. _p\\ EXIST. INV �� S // PANEL #250015 0004 C FLAT ROOF MASTER 13,8' \ EXISTING 77.5 / BEDROOMCr BATH BATH BEDROOM \ \\ SLAB RAGS 2 / 56.55 LOCUS PLAN. NO SCALE z #3 KITCHEN \ \ / FLAT ROOF 7.6' o S �` �A 3 D SEASONAL PORCH Q I ' % %a i • z FIRST FLOOR + Q \ / / i LOCUS y #56 O,\ 1 #21 L LAKELAND � INDIAN N j AVENUE MEMORIAL DRIVE ASSESSORS MAP 60 \ REPLUMB OUTLET PIPES LOCUS f \ AS SHOWN (LICENSE ASSESSORS MAP 60 BATH GARAGE UNFINISHED BASEMENT LAUNDRY BASEMENT FLOOR INTERIOR LAYOUT PER OWNER �, PARCEL 52 � i NOTE: EXISTING LAUNDRY AND BATHROOM IN UNFINISHED BASEMENT TO REMAIN CONNECTED TO OLD TITLE 5 LEACHING SYSTEM AS PLUMBING GOES DOWN THROUGH THE BASEMENT SLAB. PLUMBER) PUMP AND \ \ ABANDON EXISTING LEACHING PITS IN ACCORDANCE WITH TI TLE 5. PARCEL 50 PLAN VIEW SCALE: 1' = 10 FEET 0 5 10 20 FT, may_ 0 7 Fr`_.it valid i r e Efs= , IR OF SEPTIC SYSTLrv1 C.iLV, due to State and Local septic Lzrd of I ealth revi--w and approval is reel-nd L:r 2..y future additions/renovatious/alterstiztns 0 se rage fzailities and/or structures/di;c1ling. Yarmouth Health Departrz_ml k1k . IWC Xzll I� A 28 MPNN s-\ Ii III i REVISIONS NO. DATE DESCRIPTION GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL. 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL. 6. REPLACE ALL EXCAVATED MATERIAL WITH CLEAN GRANULAR SAND, FREE FROM ORGANIC MATERIAL AND DELETERIOUS SUBSTANCES. MIXTURES AND LAYERS OF DIFFERENT CLASSES OF SOIL SHALL NOT BE USED. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN TWO INCHES. A SIEVE ANALYSIS, USING A #4 SIEVE, SHALL BE PERFORMED ON A REPRESENTATIVE SAMPLE OF FILL. UP TO 45% BY WEIGHT OF THE FILL SAMPLE MAY BE RETAINED ON THE #4 SIEVE. SIEVE ANALYSES ALSO SHALL BE PERFORMED ON THE FRACTION OF FILL SAMPLE PASSING THE #4 SIEVE, SUCH ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SPECIFICATIONS: 1007. MUST PASS #4 SIEVE (4.75 mm EFFECTIVE PARTICLE SIZE) 107.-100% MUST PASS #50 SIEVE (0.30 mm EFFECTIVE PARTICLE SIZE) 0%-20% MUST PASS #100 SIEVE (0.15 mm EFFECTIVE PARTICLE SIZE) 07.-5% MUST PASS #200 SIEVE (0.075 mm EFFECTIVE PARTICLE SIZE) 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL. 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, LOCA11ON AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO THE START OF CONSTRUCTION. 8. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. L"9BAGE GRINDER IS NOT MMENDED DUE TO RECOGNIZED RSE IMPACTS TO THE LEACHING LITY. 9. EXITING INVERTS ARE TO BE CHECKED BY THE CONTRACTOR PRIOR TO CONSTRUCTION CONFIRM LOCATION & NUMBER OF INVERTS. 0. THE ENGINEER IS TO BE NOTIFIED OF ANY FIELD CHANGES THAT MAY BE REQUIRED. 349 Main Street, (RT. 28) Unit D W. Yarmouth Massachusetts 02673 508 778 8919 PROJECT TITLE: DESIGN FOR SEWAGE DISPOSAL SYSTEM REPAIR ;62 LAKELAND AVENUE SO. YARMOUTH MASSACHUSETTS APR 2 4 2C )7 PREPARED FOR: HARRIET SUTHERLAND 62 LAKELAND AVENUE SOUTH YARMOUTH MA 02664 DATE: APRIL 24, 2007 COMP. DESIGN: K. HEALY CHECK: M. DIBB DRAWN: K. HEALY FIELD: D. GAZZOLO / J. McCARTIN FILE NO. 9223-SEP.DWG DWG NO. 5806-01 JOB NO. 4-9223.00 SHEET 1 OF 1 CONCRETE COVER TO WITHIN 6" OF GRADE LOAM & SEED DISTURBED AREAS 3' MAX. ! COMPACTED FI L 36" MAXIMUM,12"MINIMUM ° ° � O o°o { 3" LAYER � Q 0 PEASTONE 34 24 'EF 08 E 0l 0 EC. 0 CI] 0 0 0 DEPTH to C7 - 3/4" - 1 1/2- /2"56" 56" WASHED STONE /, 84 PROFILE: NOT TO SCALE 1 DATUM:I 0OFA/gS EL.=A VERTICAL DATUM: ASSUMED ��' I o�� MARK D.S9c�N i DESIGN CRITERIA: TOP FOUNDATION FIRST PIPE LENGTH 1 i I DIBB CONCRETE COVERS TO WITHIN7TO BE SET LEVEL BENCH MARK SET: HYDRANT TAG BOLT EL.= 78.3 6" OF FINISHED GRADE. FOR MIN. 2' i / 0 CIVIL � I DESIGN FLOW: ' / tlo' 4: " 7 3 110 330 FINISH � ELEVATION 80.10 � � ^ / � ��, A F; BEDROOMS AT G.P.B./D G.P.D. CLEANOUT 4" PVC SCH 40 scH 40 4 PVC scH 40LEACHING OCHoAM�BERG /�9REQUIRED SEPTIC TANK: 25' 25' 10 0 0 0 0 BENCHMARK / I =B I=D 1=G 0 0 0 Co 0 0 0 0 0 0 i HYDRANT TAG BOLT I / y� y/LO, j = I v 330 X 200% 660 GAL. I=C I=E H ELEV 80.10 ASSUMED / �/ I SEPTIC TANK PROVIDED: = 1500 GAL. 5 OUTLET 1=F //' SEPTIC TANK DIST. BOX 5.1 SEPARATION ; J EST. HIGH GROUNDWATER ` , i <4� U-)� �j 1_"1i I SIZE OF LEACHING FACILITY REQUIRED. DESIGN PERC. RATE: <2 MIN./ INCH �?SoO LONG TERM APPL. RATE 0.74 G.P.D/S.F. O M \N /�� / �/ / I INVERT ELEVATIONS: ��� �� 13' �' TWO RISERS // I 330 GPD 0,74 GPD/SF = 446 S.F. " / \ E � / 5 TO WITHIN 6 OF GRADE / \ TOP OF FOUNDATION 79.30 A �� \ J SIZE OF LEACHING FACILITY PROVIDED: .> / 1/ / 4 INVERT AT BUILDING 75.35 B REPLUMB EXISTING USE C4> 500 GALLON C❑NC, 4" INVERT AT SEPTIC TANK (IN) 74.85 C OI1 LEACHING CHAMBERS 7'X2'X40' / " 74.60 D / TP#1 �. / / / 1500 GALLON 4 INVERT AT SEPTIC TANK (OUT) �� P I / $� �/ / SEPTIC TANK \ I 4" INVERT AT DIST. BOX (IN) 74.37 E ��� \0,01 I �7 / /� ^/J/ / \ �'' I SIDEWALL-= 2C7+40') X 2' = 188 " 74.20 F �' \ � �\ 1.-,(�S�C y/ % / / \ 1 BOTTOM 7' X 40' = 280 4 INVERT AT DIST. BOX (OUT) \ P /// ��,� / /� r7��/ �\ I 468S.F. .000 <a 68 S,1- x 0,74 Gr D/SF = 34 6 G P D - .., ($J a D BOX �' r INVERTS AT LEACHING FACILITY: �+ / ,� c�2 /// j < (S� \ / / i ♦ �i /10.0 \ 1 4 INVERT AT LEACHING CHAMBER 74.1 G BREAKOUT 74.6 /! 1 �\ BOTTOM OF LEACHING CHAMBER 72.1 H i \ ��� /� / �f PROPOSED _ _ / � 7X40 S.A.S. 10.0 ADJUSTED GROUNDWATER �� / I? / BOTTOM OF HOLE 67.0 J O S EXISTING 1983 S.A.S TO REMAIN WG Z LOCUS INFORMATION VARIANCES REQUESTED: �� Al / \ \ �� '. / CURRENT OWNER: HARRIETT L. SUTHERLAND, TR TITLE V: SECTION 15.211: (1) TO ALLOW LEACHING SYSTEM TO BE 5' OFF O G BASE. .� TITLE REFERENCE: DEED BOOK 8561, PAGE 80 THE FRONT PROPERTY LINE IN LIEU OF 10'. EXIST. -INV =72.4��% / h, PLAN REFERENCE: PLAN BOOK 95, PAGE 41 EXISTING REPLUMB " 0. - -- OHW ASSESSORS MAP: 60 \ O / INTERIOR �� I _._----- OHW OH TITLE V: SECTION 15.211: (1) TO ALLOW SEWER LINE EXITING BUILDING TO BE I ��, \ ;A, 1 STORY �` OHw PARCEL: 51 \ o �' WOOD DWELLING TO INV -75.35 W 4' FROM WATER LINE IN LIEU OF 10'. I \ \ -c>r GAS EXISTING I � ZONING DISTRICT: R-40 i 1 A \ O O�` FF=80.3 EXIST. INV r TOF=79.3 =77.4 MEJER CONCRETE SETBACKS: FRONT 30' I \ 4i 6 -6 FULL / / DRIVE SIDE 20 / ' REAR 20 I < \ < < :FOUNDATION 1 m % // � � li,� �/� o -.4\ x`-80 i MINIMUM LOT SIZE: 40,000 S.F. LP/ \ O \s EXIST. INV y,� ��l \ \ \ =77.3//�� 1 �� EXISTING LOT AREA: 11,832t S.F. FLOOR PLAN \ \ p OVERLAY DISTRICT: APD \ �O \ O SEASONAL �v �r1'� - \ 'O/ PORCH NITROGEN SENSITIVE \ OT\ CONCRETE �EXISTING / ON SLAB // C; ((��� �� ,�� / ao ZONE: YES - ZONE II \ v\ <� DRIVEWAYS FEMA FLOOD BEDROOM LIVING ROOM/<\\ �' > ,\gr /� O, ZONE DISTRICT: "C" 6/17/86 GREAT ROOM 8 i #2 DINING 4. _p\\ EXIST. INV �� S // PANEL #250015 0004 C FLAT ROOF MASTER 13,8' \ EXISTING 77.5 / BEDROOMCr BATH BATH BEDROOM \ \\ SLAB RAGS 2 / 56.55 LOCUS PLAN. NO SCALE z #3 KITCHEN \ \ / FLAT ROOF 7.6' o S �` �A 3 D SEASONAL PORCH Q I ' % %a i • z FIRST FLOOR + Q \ / / i LOCUS y #56 O,\ 1 #21 L LAKELAND � INDIAN N j AVENUE MEMORIAL DRIVE ASSESSORS MAP 60 \ REPLUMB OUTLET PIPES LOCUS f \ AS SHOWN (LICENSE ASSESSORS MAP 60 BATH GARAGE UNFINISHED BASEMENT LAUNDRY BASEMENT FLOOR INTERIOR LAYOUT PER OWNER �, PARCEL 52 � i NOTE: EXISTING LAUNDRY AND BATHROOM IN UNFINISHED BASEMENT TO REMAIN CONNECTED TO OLD TITLE 5 LEACHING SYSTEM AS PLUMBING GOES DOWN THROUGH THE BASEMENT SLAB. PLUMBER) PUMP AND \ \ ABANDON EXISTING LEACHING PITS IN ACCORDANCE WITH TI TLE 5. PARCEL 50 PLAN VIEW SCALE: 1' = 10 FEET 0 5 10 20 FT, may_ 0 7 Fr`_.it valid i r e Efs= , IR OF SEPTIC SYSTLrv1 C.iLV, due to State and Local septic Lzrd of I ealth revi--w and approval is reel-nd L:r 2..y future additions/renovatious/alterstiztns 0 se rage fzailities and/or structures/di;c1ling. Yarmouth Health Departrz_ml k1k . IWC Xzll I� A 28 MPNN s-\ Ii III i REVISIONS NO. DATE DESCRIPTION GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL. 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL. 6. REPLACE ALL EXCAVATED MATERIAL WITH CLEAN GRANULAR SAND, FREE FROM ORGANIC MATERIAL AND DELETERIOUS SUBSTANCES. MIXTURES AND LAYERS OF DIFFERENT CLASSES OF SOIL SHALL NOT BE USED. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN TWO INCHES. A SIEVE ANALYSIS, USING A #4 SIEVE, SHALL BE PERFORMED ON A REPRESENTATIVE SAMPLE OF FILL. UP TO 45% BY WEIGHT OF THE FILL SAMPLE MAY BE RETAINED ON THE #4 SIEVE. SIEVE ANALYSES ALSO SHALL BE PERFORMED ON THE FRACTION OF FILL SAMPLE PASSING THE #4 SIEVE, SUCH ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SPECIFICATIONS: 1007. MUST PASS #4 SIEVE (4.75 mm EFFECTIVE PARTICLE SIZE) 107.-100% MUST PASS #50 SIEVE (0.30 mm EFFECTIVE PARTICLE SIZE) 0%-20% MUST PASS #100 SIEVE (0.15 mm EFFECTIVE PARTICLE SIZE) 07.-5% MUST PASS #200 SIEVE (0.075 mm EFFECTIVE PARTICLE SIZE) 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL. 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, LOCA11ON AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO THE START OF CONSTRUCTION. 8. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. L"9BAGE GRINDER IS NOT MMENDED DUE TO RECOGNIZED RSE IMPACTS TO THE LEACHING LITY. 9. EXITING INVERTS ARE TO BE CHECKED BY THE CONTRACTOR PRIOR TO CONSTRUCTION CONFIRM LOCATION & NUMBER OF INVERTS. 0. THE ENGINEER IS TO BE NOTIFIED OF ANY FIELD CHANGES THAT MAY BE REQUIRED. 349 Main Street, (RT. 28) Unit D W. Yarmouth Massachusetts 02673 508 778 8919 PROJECT TITLE: DESIGN FOR SEWAGE DISPOSAL SYSTEM REPAIR ;62 LAKELAND AVENUE SO. YARMOUTH MASSACHUSETTS APR 2 4 2C )7 PREPARED FOR: HARRIET SUTHERLAND 62 LAKELAND AVENUE SOUTH YARMOUTH MA 02664 DATE: APRIL 24, 2007 COMP. DESIGN: K. HEALY CHECK: M. DIBB DRAWN: K. HEALY FIELD: D. GAZZOLO / J. McCARTIN FILE NO. 9223-SEP.DWG DWG NO. 5806-01 JOB NO. 4-9223.00 SHEET 1 OF 1