Loading...
HomeMy WebLinkAboutEngineered Plan - 2006SYSTEM PROFILE TOP FNDN. AT EL. 17.2'Nor To SCALE) ACCESS COVER TO WITHIN 6" OF FIN. GRADE ( ACCESS COVER (WATERTIGHT) TO ,R 1 MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM 1 �(p�77 2" DOUBLE WASHED PES ONE ' k�t t RUN PIPE LEVEL /` �j FOR FIRST 2' 13.5' EXISTING 1000 js+ GALLON SEPTIC\14.3'±* ` 13.0' �2.5' AROUND TANK (H- -1-0) GAS RE -USE SEE NOTE BAFFLE 13.27' o0 13.10' -' 2' - 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 {2]) MIN. �o EMS 14 DEPTH OF FLOW = 4 (13 % SLOPE) (-1-7. SLOPE) TEE SIZES: 3/4" TO 1 1/2" DOUBLE WASH -ED STONE INLET DEPTH = 10" - OUTLET DEPTH - 14„ FOUNDATION EXIST. SEPTIC TANK 8' D' BOX 3' LEACHING FAQ ITY *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF ALTERNATE BENCHMARK: USE TOP FNDN SEPTIC SYSTEM THIS AREA AT ELEV. 17.2' THE INSTALLER SHALL CONFIRM MIN. SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE -USE PROVIDE INSPECTION PORT WITHIN 6" OF FINISH GRADE 16.0' M 5.2' TEST HOLE LOGS ENGINEER: RICK JUDD, RS WITNESS: L MULKEEN, RS DATE: 1/5/06 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS AUGER HOLE Q ELEV. 0" 16.8' Ap SL 12" 1OYR 3/2 Bw LMS 33" 1OYR 4/6 14.05' PERC C F -M RTE 28 LOCUS i Q hQ U 2 _ CARVER ti LOCATION MAP NTS ASSESSORS MAP 30 PARCEL 81 VARIANCE REQUESTED UNDER MAX. FEASIBLE COMPLIANCE: 15.405 1a: REDUCTION IN SETBACK. SAS TO LOT UNE (10' TO 5') SAND 4.4 1OYR 6/4 SHED- BENCH MARK - HYDRANT 1510 \'f ON TAG 976 EL 18.2 + 132" •7y 5.8' 15.9 1 160 //� 0, NO GROUNDWATER ENCOUNTERED . 3" HOLLY + EXIST. ST 1s.. NOTES: ' (�F 15.7 Oo SEPTIC DESIGN: NOT -ALLOWED NGVD s __) -_ EXISTING DESIGN FLOW: 3 BEDROOMS (110 GPD) = 330 GPD 2. MUNICIPAL WATER IS DECK 16'5 LOT 9 USE A 330 GPD DESIGN FLOW 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. EXIST. 10,000 SFf �,'� 15'8 SEPTIC TANK: 330 GPD (2 ) 660 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 �,. DWELL USE A ____ GALLON SEPTIC TANK RE -USE EXISTING 5. PIPE JOINTS TO BE MADE WATERTIGHT. 18 i s' } +16.9 TOP FNDN = 16 8 Y 1000 ( ) 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ELEV. 17.2' j 30" TREE ,��o �: LEACHING: ENVIRONMENTAL CODE TITLE V. } APPROX. 1' i SIDES: 2(36.25 + 7.83) 2 (.74) = 130.5 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT CRAWLSP. - � i 7. 17.1 i I _ �1 TO BE USED FOR ANY OTHER PURPOSE. BOTTOM: 36.25 x 7.83 (.74) - _ 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4 PVC. .. D 16.8 +16. TOTAL: S.F. � - 460 340.5 GPD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT �H 171 17. USE 5 HIGH CAPACITY INFILTRATORS WITH 2.5' INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED \4- 7.0 SLAB ,i7. `c ® O FROM BOARD OF HEALTH. \O\�0. 5 ,�� �i ®v STONE ALL AROUND AND 14 UNDER 10. PUMP & REMOVE FAILED LEACH PIT 17 16. 17.3 �15.9/15.5 REMOVE ALL CONTAMINATED \ 1 P 16.0 SOILS WITHIN 5' OF NEW SAS \ -k `� DRIVE \!�5 i AND REPLACE WITH CLEAN MED. 7.4 `� %`+ 1 ® _ SAND. looJLEGEND'wiss7.1 N v TITLE 5 SITE PLAN PROPOSED SPOT ELEVATION OF 15.3 100x0 EXISTING SPOT ELEVATION 75 TAN GLEWOOD DRIVE NOTE: PROP. INVERT INTO SAS IS \16.4 \ IN THE TOWN OF: APPROX. 3' BELOW CRAWLSPACE16 q �� 1 UU PROFQ.SED CONTOUR (WEST) YARMOUTH FLOOR c5 " OF S"PTIa` S?« E -i%' %V, e'f(0 P' EXISTINGtiCONTOF�R �s re.=r PREPARED FOR: ROBERT MCCLAIN +15.2 20 0 20 40 60 BOARD OF HEALTH a MASCALE: 1» = 20' DATE DATE: JANUARY 9, 2006 � off 508-362-4541 fox 508 362-9880 Q LS o����,(N OF LF OF �Asc ARNE H y MAR 1.0 2006 down cape engineering, Inc. o� OJALAH. A E, CIVIL ENGINEERS No 179 OJALA HEALTH DEPT. w No. 26348 LAND SURVEYORS F���STE 05-305939 main st. yarmouth, ma 02675 ARNE H. OJALA, . , P.L.S. DATE