Loading...
HomeMy WebLinkAboutEngineered Plan - 2018t *OFFSET TO FOUNDATION ALL OTHER OFFSETTS TO CORNERBOARDS LEGEND 1j TH 1 TEST HOLE LOCATION, NUMBER --. WATER LINE MARKINGS -------i_ ------- OVERHEAD ELECTRIC WIRES (IF SHOWN) GAS LINE MARKINGS ,),(j EXISTING &PROPOSED ELEVATIONS ('X' MARKS POINT) (inches) ELEV.(feet) EXISTING CONTOUR 0 PROPOSED CONTOUR y UTILITY POLE (IF SHOWN) EXISTING DRAINAGE CATCH BASIN -------- x ----- FENCE (IF SHOWN, NOT ALL SHOWN) u, TREE (IF SHOWN, NOT ALL SHOWN) REV. 7/03/18 --LEACHING BED WIDTH & LOCATION REV. 6/13/18 --LEACHING BED RAISE GRADES OVER PROPOSED SEPTIC TANK, AS SHOWN. JOB N0. 6 -OS NOTES Connors.dwY1g 1. LOCUS IS A.M. 40, PARCEL 47. FB33/60 SB14/46 2. ELEVATIONS SHOWN ARE ASSIGNED. 3. LOCUS IS IN FLOOD ZONE X(0.2% RISK) ON FIRM DATED JULY 16, 2014. 4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) 5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. 6. COMPONENTS TO BE AASHTO H-10, UNLESS NOTED. 7. INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14". 8. IF TWO OR MORE. LINES, WATER TEST D -BOX FOR EQUAL FLOW D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. 9. DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. COVERS: BUILD UP COVERS TO 6" BELOW GRADE --1 ON D -BOX, 2 ON LEACHING. 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. -1/8 TO 1/2" PEA STONE ON TOP. 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). TEST HOLE 1 13. PUMP AND FILL ANY EXISTING CESSPOOL/LEACHPIT. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. DEPTH (inches) ELEV.(feet) 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. 0 12.3 A layer 10yr 3/2 TEST HOLE DATE: June 7, 2018 6" loamy sand 11.8 CENTER OF NEW SEWER LINE PERFORMED BY: Ron Cadillac, Soil Evaluator a TO EXIT 22.5" BELOW TOP WITNESSED BY: Amy Von Hone, RS, CHO B layer 10yr 5/6 OF FOUNDATION. PERC RATE:' <V-26"/inch (B layer) 2D"o loamy sand SOIL SURVEY(1993): Carver coarse sand 34„ Invert 10.60 GEOLOGIC MAP(1986): Harwich outwash plain deposits 9.5 Proposed REPLUMB 19 ADS ARC 36LP Invert 10.22 Proposed CHAMBERS C1 layer 2.5y 7/4 Use Gas Baffle Invert 9.75 Top Units.=10.07 medium sand Proposed S=1/8"/ft 9" min. cover ® Filter Cloth Proposed S=1/4"/ft 3" Max. S=1 /8' /ft L/ ::.: Invert 10.47 1500 Gal. Septic Tank --� ����=-- Inspection Port '- 90" -� ---��4.8 C2 layer 2.5y 5/2 11 Proposed _______ 3.8" 108" sandy loam 3.3 Invert 9.72 6" Stone or compact Proposed r I 4 10' -� 16' -� N - 3'- Hi i I 3, DESIGN DATA CD BEDROOMS: 3 GARBAGE GRINDER: No \ REQUIRED CAPACITY: - 330 GPD SEPTIC TANK: 1500 GAL. EFFECTIVE LEACHING AREA: 449.35 SF 4.73 SF/LF X 5'/UNIT=23.65 S.F/UNIT 19 UNITS X 28.65 SF/UNIT=449.35 SF(EFFECTIVE) DESIGN CAPACITY: 332.5 GPD [(449.38 SF) X .74 GPD/SF] EXISTING FLOOR PLAN NOT TO SCALE THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN ORIGINAL RED STAMP AND SIGNATURE. Bottom USGS Adjustment 2018 B LEACH AREA USE 19 ADS ARC 36LP CHAMBERS IN A 30' X 8.5' X 8" DEEP(3.8" INV.) BED, PLUS ONE 34" X 5' UNIT ON END, AS SHOWN. MAXIMUM FEASIBLE COMPLIANCE APPROVALS REQUESTED: 1. VARY SEPARATION TO HIGH GROUNDWATER BY 1' (4' PROVIDED). 310 CMR 15.212 2. VARY COVER OVER SEPTIC TANK TO BE 6" 310 CMR 15.228(1) 3. NO RESERVE AREA IS SHOWN. 310 CMR 15.448 SITE PLAN FOR PATRICIA A. CONNORS LOT 23, 26 CANDLEWOOD LANE, W. YARMOUTH, MA JUNE 12, 2018 SCALE: 1"=20' RONALD J. CADILLAC, PLS, RS PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 HEALTH AGENT APPROVAL DATE 0 (508) 775-9700 PAGE 1 OF 1 C 2018 BY R.J. CADILLAC In rn a; Y 0 0 m z Q J a_ BENCH MARK --TOP OF SPIKE SET DOWN 1"=10.32 ASSIGNED (30•-4' OFF HOUSE CORN., 8 1/2' OFF FENCE) FENCE IS 3' TO 4' OFF LOT UNE 16.72 s mss- V`0 F BENCH MARK --TOP NE CORNER I \N CONIC. -BULKHEAD=11.99 ASSIGNED I 10. N/F BOUCHERio,� r � / 9,9 N gyp. • t (1.3? 1. x 10.2 x 10.4 x RAISE GRADES OVER PROPOSED SEPTIC TANK, AS SHOWN. N /F T.O.Y. X X 12.66± 10.2 Top Foundation. 1 SO fi0.2 100 9.6 " 9.6 .0 T 13:.. 10.3 11.7C1110 �O�'Gi y KGs Z. 11,7 X 1\11,64 x 11.6 8LOT 2311.4 I1,740±S.F. 4=42.28' x 9.7 1 10.00 x 9 11.56 n 10.8 7 �' ,p ��\ x 9.8 9.6 . 0.1 r11.3 X �Q. 40�� X 10.8 �,�^�°' 010,3 0.0 /10,11 w a_ 0 BDRM NOTES Connors.dwg 1. LOCUS IS A.M. 40, PARCEL 47. FB33/60 SB14/46 2. ELEVATIONS SHOWN ARE ASSIGNED. 3. LOCUS IS IN FLOOD ZONE X(0.2% RISK) ON FIRM DATED JULY 16, 2014. 4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) 5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. 6. COMPONENTS TO BE AASHTO H-10, UNLESS NOTED. 7. INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14". 8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. 9. DEPTH OF COMPONENTS NOT TO EXCEED :3', OR VENTING MUST BE .PROVIDED. COVERS: BUILD UP COVERS TO 6" BELOW GRADE --1 ON D -BOX, 2 ON LEACHING. 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). TH 1 TEST HOLE LOCATION, NUMBER -./ WATER LINE MARKINGS AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. E -OVERHEAD -ELECTRIC WIRES (LF SHOWN) 14. ALL CONSTRUCTION TO MEET G GAS LINE MARKINGS Pern 9.5 x 12,0 EXISTING & PROPOSED ELEVATIONS ('X' MARKS P INN A .Layer 1Oyr .3/2 EXISTING CONTOUR Boat• g-� PROPOSED CONTOUR any, sewn 0 -UTILITY POLE (IF SHOWN) ® EXISTING DRAINAGE CATCH BASIN flo, x - FENCE (IF SHOWN, NOT ALL SHOWN) PERC RATE: <1'-26"/inch (B layer) 0 TREE (IF SHOWN, NOT ALL SHOWN) REV. 6/13/18 --LEACHING BED Nary w a_ 0 BDRM NOTES Connors.dwg 1. LOCUS IS A.M. 40, PARCEL 47. FB33/60 SB14/46 2. ELEVATIONS SHOWN ARE ASSIGNED. 3. LOCUS IS IN FLOOD ZONE X(0.2% RISK) ON FIRM DATED JULY 16, 2014. 4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) 5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. 6. COMPONENTS TO BE AASHTO H-10, UNLESS NOTED. 7. INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14". 8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. 9. DEPTH OF COMPONENTS NOT TO EXCEED :3', OR VENTING MUST BE .PROVIDED. COVERS: BUILD UP COVERS TO 6" BELOW GRADE --1 ON D -BOX, 2 ON LEACHING. 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). TEST HOLE 1 13. PUMP AND -FILL ANY EXISTING CESSPOOL/LEACHPIT. -REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. DEPTH (inches) ELEV.(feet) 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. p 12.3 A .Layer 1Oyr .3/2 TEST HOLE DATE:. June. 7, 2018. 6„ loamy sand 11.8 CENTER OF NEW SEWER LINE PERFORMED BY: Ron Cadillac, Soil Evaluator TO -EXIT 22.5" BELOW TOP WITNESSED BY: Amy Von Hone, RS, CHO flo, -B layer 10yr 5/6 OF FOUNDATION. PERC RATE: <1'-26"/inch (B layer) 20» loamy sand SOIL SURVEY(1993): Carver coarse sand Invert 10 60 GEOLOGIC MAP(1986) H ' h t h I' d t 34„ 9 5 - VY ou was p am eposl s Proposed REPLUMB Invert 10.22 19 ADS ARC 36LP Proposed CHAMBERS C1 layer 2.5y 7/4 Use Gas Baffle Invert 9.75 medium sand Proposed Top Units.=10..07 S-1 /8"/ft 9" min. cover ® Filter Cloth Proposed S=1 /8"/ft 3" Max. 1500 Gal. S=1 /8 /ft inspection Port 90'' --°-' ='� ` =� 4.8 Invert 10.47 C2 layer 2.5y 5/2 t Proposed Septic Tank -_________ 1 l p 3.8" 108" sandy Loam 3.3 I Invert 9.72 9.4 j Invert 9.92 ProposedBottom l S" Stone or compact Proposed 4' I i 10 i - 2$ _ �--1 --t High Ground Water=5.4 3' Ma' 20G8 Adjustment DESIGN DATA - Za e B Observed Water --4.8 BEDROOMS: 3 -GARBAGE -GRINDER: No_- _ -_-_ LEACH -AREA---- REQUIRED AREA--- REQUIRED CAPACITY: 330 GPD SEPTIC TANK: 1500 GAL. USE 19 ADS ARC 36LP CHAMBERS IN A EFFECTIVE LEACHING AREA: 449.35 SF 30' X 8.5' X 8" DEEP(3.8" INV.) BED, PLUS 4.73 SF/LF X 5'/UNIT=23.65 S.F/UNIT ONE 34" X 5' UNIT ON END; AS SHOWN. 19 UNITS X 28.65 SF/UNIT=449.35 SF(EFFECTIVE) DESIGN CAPACITY: 332.5 GPD [(449.38 SF) X .74 GPD/SF] / ENTRY BDRM m L<lT. DNRM i BDRM LVRM EXISTING FLOOR PLAN NOT TO SCALE THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN ORIGINAL RED TA ANDS SIGNATURE. IH OF APA V �St1 OF MASsgcy RONALD RONALD >F':I'TIC SVS'I'H:M JAMES JAMES septic variances. CADILLAC fn " CADILLAC J # 1060 # 35779 wal is required fur O? ins/alterations to FFG/STE�� iA SS�O O� dwelling: SANITAR% II QQty �O�SUR%J 4s arfnu�nt wee 'ALTH AGENT APPROVAL DATE MAXIMUM FEASIBLE COMPLIANCE APPROVALS REQUESTED: 1. VARY SEPARATION TO HIGH GROUNDWATER- BY 1' (4' PROVIDED). 310 CMR 15.212 2. VARY COVER OVER SEPTIC. TANK TO BE 6" 310 CMR 15.228(1) 3. NO RESERVE AREA IS SHOWN. 310 CMR 15.448 SITE PLAN FOR PATRICIA A. CONNORS LOT 239 26 CANDLEWOOD LANE, W. YARMOUTH, MA JUNE 129 2018 SCALE: 1 "=20' RONALD J. CADILLAC, PLS, RS PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 (508) 775-9700 PAGE 1 OF 1 02018 BY R.J. CADILLAC