Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 2010S Permit valid for REPAIR OF SEP -TIC SYSTEM ONLY, due to State and Local septic variances. Board of Health review and approval is required for any future add itions/reniwa tions/alterations to sewage facilities and/or structures/dwelling. Yarmouth Health Department APPROVED' a `.S -5:� Date OF No. 1140 C C C CAPTAIN B LO U NT LOAD SAN I R a� � 'S�`-�v 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLYRp AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY R [ R- o v D 13. REMOVE ALL UNSUITABLE SOILS 5 FEET AROUND LEACHING TO EL. 24.03 OR TOP OF C LAYER AND REPLACE WITH LHEAL01 CLEAN MEDIUM SAND PER TITLE V. 14. NO PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING 15. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 16. PLACE 40 ml POLY BARRIER AROUND LEACHING ON ALL SIDES AT EDGE OF SOIL REMOVAL FROM EL, 27.47-24.00 TO PREVENT BREAKOUT 17. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPECIFIED) PROPOSED SEPTIC SYSTEM UPGRADE PLAN 19 CAPTAIN BLOUNT ROAD, SO. YARMOUTH, MA LEGEND Prepared for: PROPOSED CONTOUR ® PROPOSED SPOT GRADE -- 98 -- EXISTING CONTOUR SITE + 96.52 EXISTING SPOT GRADE --— EXISTING WATER SERVICE DARREN M. MEYER, R. S. Nreller and Assoc. 'TEST PIT $ 1 "= 20' DM M o PO BOX 981 EASTSANDW/CH, W 02537 0 RD. CAPT NOKES CHECKED LOCUS MAP N.T.S. LOT.- 194 GENERAL NOTES: (508) 775-0735 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL 04/14/10 BOARD OF HEALTH AND THE DESIGN ENGINEER. 1 of 2 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: - 310 CMR 15.405 (1) (h): 1) A 0.95 FT. VARIANCE FROM 310CMR15.212 TO ALLOW LEACHING TO BE M = EL. 28.0 4.05 FT ABOVE ADJ. WATER VS REQ'D 5 FT. 1LKHEAD FOUND. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING taining wall by others. FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. oposed 1,50OG 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. otic tank 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. `ing Cesspool 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED e 10) TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING Soil Removal CONSTRUCTION. 13) 10. EXISTING CESSPOOLS TO BE PUMPED, CRUSHED AND REMOVED PER TITLE V. e note 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLYRp AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY R [ R- o v D 13. REMOVE ALL UNSUITABLE SOILS 5 FEET AROUND LEACHING TO EL. 24.03 OR TOP OF C LAYER AND REPLACE WITH LHEAL01 CLEAN MEDIUM SAND PER TITLE V. 14. NO PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING 15. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 16. PLACE 40 ml POLY BARRIER AROUND LEACHING ON ALL SIDES AT EDGE OF SOIL REMOVAL FROM EL, 27.47-24.00 TO PREVENT BREAKOUT 17. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPECIFIED) PROPOSED SEPTIC SYSTEM UPGRADE PLAN 19 CAPTAIN BLOUNT ROAD, SO. YARMOUTH, MA 05/07/10 - REVISION - GRAVITY FEED r. Prepared for: Bluewater Engineering by: Surveying by: SCALE DRAWN DARREN M. MEYER, R. S. Nreller and Assoc. 1 "= 20' DM M MAP., 067 PO BOX 981 EASTSANDW/CH, W 02537 Route 28 Centerville, MA 02632 DATE CHECKED SHEET NO. LOT.- 194 508-362-2922 (508) 775-0735 04/14/10 DMM 1 of 2 05/07/10 - REVISION - GRAVITY FEED r. Mil INV. -28.02 PROPOSED 1,500 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTSALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL, OR EQUAL NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. 2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. DESIGN CRITERIA 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. 5) PLUMBING TO BE MODIFIED TO MEET OUTLET LOCATION AND ELEVATION. (PLUMBING PERMIT REQUIRED.) DESIGN CRITERIA: 3 BEDROOM SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D./BR DESIGN FLOW: 38R x 110 GPD/BR = 330 gpd (MIN REQ'D) GARBAGE GRINDER: NO PROPOSED SEPTIC TANK: 330 gpd x 200% = 660 gpd USE NEW 1,50OG TANK LEACHING AREA REQUIRED: (330) = 445.94 S.F. .74 SEPTIC SYSTEM PROFILE N.T.S. PRIMARY S.A.S. USE 3 ROWS OF 5 - 11" ADS 11006D BIODIFFUSER UNITS -NO STONE AND EXTENDED 0.75' W/ CONTOURED WEDGES BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.70 SF/LF OF BIODUFUSER) (BIODIFFUSERS) 15 UNITS x 6.25 LF x 4.70 SF/LF = 440.63 SF (CONTOURED WEDGE) 3 ROWS x 0.75' x 4.70 SF/LF = 10.58 SF TOTAL AREA = 451.21 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(451.21 SF) = 333.89 GPD > 330 GPD req'd OF MAss9 A R 1140 �E'GI51E��0 SANITAR�P� FINISH GRADE=28.25 MAINTAIN 2% MIN SLOPE OVER LEACHING AREA 6.35" TO INVERT - NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:27.47 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. MIN. COVER OVER S.A.S. = 9" MAX. COVER OVER S.A.S. = 36" TWO INSPECTION PORTS(MIN.) 1 3 ROWS OF 5 UNITS AT 6.25'/UNIT + 0.75' WEDGE - 32.0'/ROW INV.ELEV.=27.08 SOIL ABSORPTION SYSTEM (PROFILE) BREAKOUT=TOP ELEV.=27.47 INV. ELEV.= 27.08 BOTTOM ELEV.= 26.55 4' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. (4.05' PROVIDED) AJD. GROUNDWATER EL.=22.50 RESTORE VEGETATIVE COVER -BACKFILL WITH CLEAN PERC SAND EXISTING SUITABLE MATERIAL EFFECTIVE WIDTH = 3 x 2.83' = 8.49'1 USE 3 ROWS OF 5 -HIGH CAPACITY ADS 110OBD BIODIFFUSER UNITS -NO STONE W/CONTOURED WEDGE TYPICAL SECTION N.T.A SOIL LOGS DATE: APRIL 1, 2010 SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614 WITNESS: AMY VONHONE, YARMOUTH BOH GROUNDWATER OBSERVED AT 54" EL. 22.20 INDEX WELL: MIW-29 ZONE: B LEVEL: 6.0 ADJUSTMENT: 0.3 ft. ADJUSTED HIGH GROUNDWATER AT EL. 22.50 Elev. TH-1 Depth 26.7 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS ELEV. TOP PROPOSED TANK D FOUNDATION 5" INSTALL RISERS W/IN 6" OF FINISH GRADE B INSTALL RISERS W/IN 6" OF FINISH GRADE (Existing) LOAMY SAND 1OYR 5/8 = 30.0 24.03 32" C1 EL.29.75t EL.29.75f F.G. EL: 28.751 SAND 2.5Y 6/4 .Y " 4" SCH 40 PVC e" 6 e' 9CS-2X to" 14 O S- 1X (MIN.) E TO BE 4*SCHH40 PVCINV.= INV.=27.20 r 27.77 Q -BOX INV.- 27.37 Prop Invert (USE DB -3) INV.=28.22 Mil INV. -28.02 PROPOSED 1,500 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTSALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL, OR EQUAL NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. 2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. DESIGN CRITERIA 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. 5) PLUMBING TO BE MODIFIED TO MEET OUTLET LOCATION AND ELEVATION. (PLUMBING PERMIT REQUIRED.) DESIGN CRITERIA: 3 BEDROOM SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D./BR DESIGN FLOW: 38R x 110 GPD/BR = 330 gpd (MIN REQ'D) GARBAGE GRINDER: NO PROPOSED SEPTIC TANK: 330 gpd x 200% = 660 gpd USE NEW 1,50OG TANK LEACHING AREA REQUIRED: (330) = 445.94 S.F. .74 SEPTIC SYSTEM PROFILE N.T.S. PRIMARY S.A.S. USE 3 ROWS OF 5 - 11" ADS 11006D BIODIFFUSER UNITS -NO STONE AND EXTENDED 0.75' W/ CONTOURED WEDGES BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.70 SF/LF OF BIODUFUSER) (BIODIFFUSERS) 15 UNITS x 6.25 LF x 4.70 SF/LF = 440.63 SF (CONTOURED WEDGE) 3 ROWS x 0.75' x 4.70 SF/LF = 10.58 SF TOTAL AREA = 451.21 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(451.21 SF) = 333.89 GPD > 330 GPD req'd OF MAss9 A R 1140 �E'GI51E��0 SANITAR�P� FINISH GRADE=28.25 MAINTAIN 2% MIN SLOPE OVER LEACHING AREA 6.35" TO INVERT - NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:27.47 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. MIN. COVER OVER S.A.S. = 9" MAX. COVER OVER S.A.S. = 36" TWO INSPECTION PORTS(MIN.) 1 3 ROWS OF 5 UNITS AT 6.25'/UNIT + 0.75' WEDGE - 32.0'/ROW INV.ELEV.=27.08 SOIL ABSORPTION SYSTEM (PROFILE) BREAKOUT=TOP ELEV.=27.47 INV. ELEV.= 27.08 BOTTOM ELEV.= 26.55 4' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. (4.05' PROVIDED) AJD. GROUNDWATER EL.=22.50 RESTORE VEGETATIVE COVER -BACKFILL WITH CLEAN PERC SAND EXISTING SUITABLE MATERIAL EFFECTIVE WIDTH = 3 x 2.83' = 8.49'1 USE 3 ROWS OF 5 -HIGH CAPACITY ADS 110OBD BIODIFFUSER UNITS -NO STONE W/CONTOURED WEDGE TYPICAL SECTION N.T.A SOIL LOGS DATE: APRIL 1, 2010 SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614 WITNESS: AMY VONHONE, YARMOUTH BOH GROUNDWATER OBSERVED AT 54" EL. 22.20 INDEX WELL: MIW-29 ZONE: B LEVEL: 6.0 ADJUSTMENT: 0.3 ft. ADJUSTED HIGH GROUNDWATER AT EL. 22.50 Elev. TH-1 Depth 26.7 A LOAMY SAND p" t0YR 4/1 26.28 5" B LOAMY SAND 1OYR 5/8 24.03 32" C1 MED - COARSE SAND 2.5Y 6/4 PERC O 22.7 19.20 1 1 90" PERC RATE <2 MIN/IN. (IN "C" HORIZON) 05/07/10 - REVISION - GRAVITY FEED