HomeMy WebLinkAboutEngineered Plan - 2018t LEGEND DCE # 18-163 TOP FOUND. EL. 61.4 ----------------- PRECAST H-10 RISERS (TYP.) 2'0 EXISTING PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE SYSTEM PROFILE (NOT TO SCALE) 1 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE IMUM .75'1OF EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[991— PROPOSED CONTOUR 198.43 PROPOSED SPOT EL. TH1 BLOCKS OR TEST HOLE 27 - SLOPE OF GROUND C -0-D UTILITY POLE ENDS FIRE HYDRANT DCE # 18-163 TOP FOUND. EL. 61.4 ----------------- PRECAST H-10 RISERS (TYP.) 2'0 EXISTING PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE SYSTEM PROFILE (NOT TO SCALE) 1 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE IMUM .75'1OF COVER OVER PRECAST 1 1 2% SLOPE REQUIRED OVER SYSTEM 159.0'-61.0' NOTE: 2" MIN. WALL THICKNESS REQUIRED BLOCKS OR 4"OSCH40 PVC MORTAR PRECAST RISERS ALL 6" MIN. SUMP TEE PIPES LEVEL 1ST 2' COMPONENTS H-10 INV'S EL. 57.2 12" MIN. INT. DIM. ENDS (7YP.) 4' SIDES 58.03' 14"TEE - .• �57. o ° o a o00 oo o® ®®oa00000000 ... °° 0 O° ° ° ° ° °t >°o°o°o°o ®�0�����®LJ� O°°° EST D'BOX'00o"° ° ° 11q 00000000 O O O° °o°o°o°o°o°o°oo°0000 BAFFLE :: '-on�n°�°�°-VELNESS 0 N 00000000 0GAS �oL�ao�®oa 57.47' o®oaao®o®oo®D®���C7®O :�o�o�000>°o°o°o°o0 0 0 o c> 55.2 >°o°O°°°° o°°°o°o°� 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. H-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. ALL AROUND PRECAST STRUCTURES (3) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.50' X 12.83' COMPACTION. (15.221 [2]) I (1 1 %SLOPE) (1 % SLOPE) 47.4' BOTTOM TH-1 NO GROUNDWATER FOUND FOUNDATION—EXISTING SEPTIC. TANK 3' D' 'BOX 12' LEACHING FACILITY **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS,, SUITABILITY FOR RE—USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE I; *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL. BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM i a BEDROOM I LA BEDROOM BEDROOM SECOND FLOOR NOTES 1. DATUM IS NAVD •88 2. -MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. e� o Z � Locus t Q c 0 ,o Dennis Pond Opro 0 J � c Exit 7 a 0 Route 6 LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 112 PARCEL 56 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO559J DATED 7/16/2014 TEST HOLE LOGS ENGINEEP. CRAIG J. FERRARI, SE #13871 WITNESS: AMY VON HONE, RS DATE: 5/30/18 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 4 ELEV. 1 �G 0» 58.4' tio�r m _ DINING ROOM KITCHEN FAMILY FILL ROOM GARAGE 12' LIVING A ROOM LS FOYER OFFICE 1OYR 3/2 22" 56.6' B FIRST FLOOR UNSUITABLE SOIL /L 54" 10YR 5/6 53.9' FLOOR PLAN PERC C NOT TO SCALE MS 10YR 7/4 SYSTEM DESIGN: Yarmouth Health Department . p VED 132" 47.4' GARBAGE DISPOSER IS NOT ALLOWED Name Date NO GROUNDWATER ENCOUNTERED EXISTING 4 BEDROOM DWELLING y DESIGN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW L -, _17 L. SEPTIC TANK: 440 GPD (2) = 880 TF!1I 5 S�TE PLAN **RE—USE EXISTING 1000 GAL. SEPTIC TANK OF LEACHING: SIDES: 2 (33.5 + 12.83) 2 (.74) = 137 GPD2�. " RIAGE L BOTTOM 33.5 x 12.83 (.74) = 318 GPD YAR F"MOUTH TOTAL: 615 S. F. 455 GPD 1 USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) PREPARED FOR WITH 4' STONE ALL AROUND TED` PAQUINI APPROVED DATE , MA BOARD OF HEALTH DATE: JUNE 6, 2018 Scale: 1"= 20' 0 10 20 30 40 50 FEET '�N OF M,18SOF bfj gc �H �= DANIELA.MAs o OJALA �-A o`'� DANIEL cy� > CIVIL" o� A. off 508-362-4541 q No. 46502 OJALAN fox 508-362-9880 No. 40980 downcape,com docn caps en�ineefin inc, SENS OFESS�O� SS/ONAL 9Na SUR`1E C/ v/7 engineers /and surveyors 939 Main Street (Rte 6A) DATE DANIEL A. OJALA, P. E., P.L.S. YARMOUTHPORT MA 02675 18-163 PAQUIN.DWC