Loading...
HomeMy WebLinkAboutEngineered Plans - 2018LEGEND RO _ gRa BRpOK OANO�N� Sapp 01 — 100 — —EXISTING CONTOUR ?I'D �N 9RpO 100.98 EXISTING SPOT GRADE eRop`� p�ER ROAD yWl EXISTING WATER SERVICE G EXISTING GAS SERVICE sj e T --- 6. H. K - - OVERHEAD WIRES s BENCHMARK TEST PIT CORNER OF STEP EXISTING LEACH PIT TO BE REMO VED BENCHMARK mo yy� ��P50P c� mo�0 EL. =101.74 oG (see note 11) � foo s` QG N 58'07'29" E 100.00 ' o o� +•9.7.80 b 97:95 35 99:65 LOCUS Q + 98,7S –t—�--f– 12' 8:62 TP 98'89 OPOSEO 9 A_9 x POLE 1 LOCUS MAP + T ��i�7_ 1- T -,J .�, 100:2 t%O 9 NOT TO SCALE EXISTING SEPTIC TANK _ 6 �T GENERAL NOTES: TOP OF TANK, EL.=98.86E ; 10066 O PAVER PATIO INV.(OUT)=97.53E •� � AV S 1 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. PAVER PATIO N 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS sun, ro m� G fndn. OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. + 98'99 shr. sono 92 LAMP • Z 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR 0 101.13 as TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE W a+ DESIGN ENGINEER. O � O O Q �' (EXISTING / Q 0 O N A Q 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ._ O •� 3 p d W ENGINEER BEFORE CONSTRUCTION CONTINUES. M ; f �o.Fs�(o ?sf GARAGE j a ; f = A 5. ALL ELEVATIONS BASED ON AN ASSIGNED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF Z Q I 100:21 -F 100 BO -`"• THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 101,4 ',I,' a a 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. OF THE PROPOSED S.A.S. ` PAVER WALK p 8• THERE ARE NO WELLS WITHIN 100' 101:09 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS +;100, :.. 0100.00 8 AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. ,. 0 ..z 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY .: LOT 40 �4 100,38 100:56 THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 0 ' .. LAMP-. .�u.::; UNSUITABLE SOILS .99� _V),0OL0fs.F. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL _ _ Q` �.: IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND 100.00 REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 9 " +• 100.25 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE / N 5807 E INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. OF Mgss9cy a 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND pavement _ NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. o PETER T. ed e of 98.98 99.18 9 99'56 100,12 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC McENTEE SYSTEM COMPONENTS NOT SHOWN ON THE PLAN VIL N No.. 35109 35 BLACK DUCK LANE PROPOSED SEPTIC SYSTEM UPGRADE PLAN 22 BLACK DUCK LANE, WEST YARMOUTH, MA FI � OWNER OF RECORD HENDERSON, ALBERT J Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 ` HENDERSON, MARY A Engineering by: SCALE DRAWN JOB. NO. PLAN REFERENCES 22 CK DUCK LN BLYARMOUTH, 1 "=20' P.T.M. 147-18 Engineering Works, Inc. WESTMA 02664 PLAN BOOK 240 – PAGE 141r� PARCEL ID: 58-280 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. 4/27/18 P.T.M. 1 Of 2 CERTIFIED PLOT PLAN, BARNSTABLE SURVEY CONSULTANTS, W. YARMOUTH, MA DATED 7/6/73 (508) 477-5313 SEPTIC TANK PROPOSED D-BOX INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & WATERTIGHT OUTLET AND SET TO 6" OF FINISH GRADE COVER SET TO 6" OF GRADE T.O.F.=101.6t -F.G. EL.=100.0t -F.G. EXISTING EL.=100.0t F.G. EL.=100.0f ` L = 12' L = 6' ® S=1% (MIN.) 0 S=1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC ( 14" EXISTING 48" LIQUID - LEVEL I GAS�BAFFLE . r► NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS, PRIOR TO INSTALLATION. 2) D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. 5) USE OF THE EXISTING SEPTIC TANK IS SUBJECT TO THE APPROVAL OF THE BOARD OF HEALTH OR IT'S REPRESENTATIVE. DESIGN CRITERIA 7.13" TO INVERT INV. =96.87'PROPOSE D `INV.=96.70 INV.=97.53f D-BOX EXISITNG INV.=96.60 BREAKOUT=TOP TOP ELEV.=97.08 INV. ELEV.=96.60 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL.97.08 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL 1 INSPECTION PORT(MIN.) AT END OF S.A.S. MAINTAIN 2% GRADE (MIN.) OVER S.A.S. INSPECTION PORT ONE (MIN.) 3 ROWS OF 7 UNITS AT 5.0'/UNIT = 35.0' SOIL ABSORPTION SYSTEM (PROFILE I ESTABLISH VEGETATIVE COVER BACKFILL WITH CLEAN NATIVE OR PERC SAND TO TOP OF CHAMBERS BOTTOM ELEV.=96.00-1 4' OF NATURALLY OCCURRING 2.83' PERVIOUS MATERIAL EFFECTIVE WIDTH=8.5 5' (MIN.) ABOVE G.W. EXISTING SUITABLE . G.W., EL=90.9 — MATERIAL USE 3 ROWS OF 7-ADS'iArc36 HD UNITS WITH NO SEPTIC SYSTEM PROFILE SEPARATION BETWEEN EACH ROW & NO STONE TYPICAL SECTION N.T.S. NUMBER OF BEDROOMS: 3 BEDROOMS SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO-S.A.S. IS NOT DESIGNED FOR GARBAGE GRINDER LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF .74 GPD/SF EXISITNG SEPTIC TANK: 1000 GALLON CAPACITY PROPOSED D-BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED USE 3 ROWS OF 7-ADS Arc 36 HD UNITS WITH NO SEPARATION BETWEEN EACH _ROW & NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.80 SF/LF OF UNIT) (Arc36 Units) 21 UNITS x 5.0 LF x 4.80 SF/LF = 504.0 SF DESIGN FLOW PROVIDED: 0.74 GPD/SF(504.0 SF) = 373.0 GPD SOIL LOG DATE: APRIL 19, 2018 SOIL EVALUATOR: PETER McENTEE PE(SE#1542) WITNESS: AMY VON HONE IRS HEALTH AGENT ELEV. TP DEPTH 98.6 0„ FILL 13" Ab LOAMY SAND 10YR 4/2 22" B LOAMY SAND PERC 10YR 5/8 18 /36" C 37" F-M SAND 2.5Y 6/4 90.9 STG. G.W. _ 92" ADJ. G.W. 90.6 1 96" PERC RATE <2 MIN/IN. "B&C" HORIZONS STANDING G.W. @ 92", (EL.=90.9) INDEX WELL, MIW-29, ZONE A,WATER LEVEL=5.53, ADJUSTMENT=0.0', MARCH 2O18 97.5 96.8 95.5 � d Mom, ry . PROPOSED S.A.S. — I00 F-------35'--------- -; S.A.S. LAYOUT 1 _ 16" �- g'S-'i (3) 5" DIA.OUTLETS r� F 2" ,5.5" 12" 1 ; 0 �: 6" Lj -'- H-10 LOADINGT L 2'.D-BOX OJ.0 NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT awc vier TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE. 4640 TBLVD HILLIARD,OHIO OHIO 43026 Are 36 DETAIL d ADVANCED DwaruGE SYSTEMS, INC. 99PUB. UNITS MUST BE STAMPED HD PROPOSED SEPTIC SYSTEM UPGRADE PLAN 22 BLACK DUCK LANE, WEST YARMOUTH, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. N.T.S. P.T.M. 147-18 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 4/27/18 P.T.M. 2 Of 2