Loading...
HomeMy WebLinkAboutEngineered Plan - 2018LOCUS KEY: EXISTING CONTOUR: - - - - O PROPOSED CONTOUR: --------- ---- ELEVATION: ���0 EXISTING SPOT 25.5 SPOT ELEVATION: PROPOSED 25.5 TEST HOLE: * UTILITY POLE: -� FENCE LINE: �O v HYDRANT: -b-- 41 N RETAINING WALL: o LOCATION MAP LOT 8B (5,446 SF) ASSESSORS MAP: 22 PARCEL: 19 PLAN BOOK: 96, PAGE: 63 REQUIRED VARIANCES FROM TITLE FIVE: 1. SECTION 15.211 (1): LEACH AREA TO BE LESS THAN 10' FROM CRAWL SPACE (VARIANCE OF 3'). 2. SECTION 15.211 (1): LEACH AREA TO BE LESS THAN 20' FROM BULKHEAD (VARIANCE OF 14'). 3. SECTION 15.211 (1): LEACH AREA TO BE LESS THAN 20' FROM CELLAR WALL (VARIANCE OF 9'). 4. SECTION 15.211 (1): LEACH AREA TO BE LESS THAN 10' FROM LOT LINE (VARIANCE OF 5' & V). 5. SECTION 15.211 (1): SEPTIC TANK TO BE LESS THAN 10' FROM LOT LINE (VARIANCE OF T). Permit valid for REPAIR OF SF,PTIC SYS14"m ONLY, . dirZ to State and Local septic variances. N Board of Health review and approval is required for any future additions/rents ations/alterations to sewage t I aunities and/or structures/d%selling. Ya, Otith Health I)eparttitent _ V�3 "A GEG� �� N 6 100 �ro m o Sr 100 rJ �XBE R NC' c,6 k09 9 �a .�,AoOJ (p, 2� olop - ---99 M 18-29 --100 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 4 BEDROOMS AT 110 GAL / DAY = 440 GAL / DAY SEPTIC TANK: 440 GAL / DAY x 2 DAYS = 880 GAL USE 1500 GALLON SEPTIC TANK r LEACHING AREA: USE 32 INFILTRATOR QUICK 4 STANDARD CAPACITY CHAMBERS AS SHOWN (SEE DETAIL x 8" EFFECTIVE DEPTH) SIDE AREA: NA (0.74) = NA GAUDAY BOTTOM AREA: 4' x 32 UNITS x 4.7 = 602 SF (0.74) = 445 GAUDAY CAPACITY = 445 GAUDAY LEACH AREA DETAIL BENCHMARK AT LEFT CORNER OF BULKHEAD ELEVATION = 100.15 SEPTIC SYSTEM SECTION COVERS WITHIN 6" OF FINISHED GRAE a ELEV. (EXISTING) d 1500 GAL SEPTIC TANK ELEV. d TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN (6" OF STONE UNDER OR MMECHANICALLY COMPACTED) FAMILY ROOM DECK 3r1 FLOOR BED ROOM BED DECK ROOM (BATH BATH 2nd FLOOR LIVING ROOM deck KITCHEN BED ROOM ft BED BATH I ROOM sh bh 1st FLOOR EXISTING FLOOR PLAN INSPECTION PORT ELEV.= 97.1 „tea �aL, 3' MAX. 1!8" er I�iI COVER II�II1 (1' MIN) ELEV 1/8"perft ELEV. 97 02 96.85 ELEV. ELEV. 96.77 96.1 D-BOX ELEV. ELEV. (6" OF STONE UNDER) e 46' x 9' � - GAS BAFFLE USE 32 INFILTRATOR QUICK 4 5.2 AT OUTLET TEE STANDARD CAPACITY CHAMBERS SEE DETAIL (8" EFFECTIVE DEPTH) ADJUSTED GROUND WATER ELEVATION = 90.9�v TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 6-6-18 PERCOLATION RATE: < 2 MIN/IN USGS GROUND WATER ADJUSTMENT: WELL: MIW-29, ZONE: A, ADJ. (MAY): 0.4' ADJUSTED GROUND WATER ELEV: 90.9 TH-1 101.0 ELEV. O/A HORIZON LOAMY SAND 101, 10YR 2/2 100.2 B HORIZON LOAMY SAND 32" 2.5Y 5/6 98.3 PERC AT 42" C HORIZON FINE-MED SAND 2.5Y 7/4 126" OBSERVED 90.5 NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. _3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D-BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING CESS POOL(S) IS TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D-BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. k...,, K ,"M.,47 i SITE PLAN LOCATION: 3 WEST RD., W. YARMOUTH, MA PREPARED FOR: BILL & JOYCE CULLEN DATE: 6-26-18 SCALE: 1" = 20' b Y: Y , SASS RIVER ENGINEERING &A-A�K ) THOMAS J. McLELN, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048