Loading...
HomeMy WebLinkAboutEngineered Plans - 2018EXISTING FLOW DIFFUSORS TO BE ABANONED IN PLACE PROPOSED SEPTIC TANK /PUMP CHAMBER - S g8�►�. E 101.22 01.42 TP +. • . , & X 101.49 EXIST. SEPTIC TANK1,1 (TO REMAIN) X 101,06 TOP, EL.=99.58 INV.(OUT), EL.=98.25f 100,85 PATI W 101.17 Ay vri7, OCISI O / ..EA OZ.=`off n► f� O / y ° R 1EXISTING L HOUSE(1150) 101.42 T.O.F.=101.3t X ....a. WALK a �100 93 LL LI Is i+ \ B a.� ` a 10,800 /S a 0, m 12IUD MAP ID: 3-85 100.37 X - �101,25 100.59 90.00 N82---4-'00" W e100,46 f aver edge a,o HO WES FLOOD ZONE DESIGNATION FLOOD MAP NO. 25001CO589J EFFECTIVE 7/16/14 ZONE AE (EL11) BENCHMARK CORNER OF STOOP EL. =100. 82 fence line 7 I � SHED if.a �...� i •' 1D0,1 U1 . II�\ 100,8 Ice r• L 100.62 11.5 99.77 99,63 Gj r\ N C') CL I a LU JOHN L. ° CHURC LL JR. a 0 o No. 0 0 Z PROPOSED S.A.S. 99 11.5' x 40' LEACH FIELD M4sS9�tia I o PETER T. MCENTEE v CIVIL No. 35109 OWNER OF RECORD DEMERJIAN, JOHN M DEMERJIAN, JEANNETTE A 230 ROSLINDALE AVE. ROSLINDALE, MA 02131 LEGEND -.,-- - 98 - .-- EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE 100. 2 PROPOSED SPOT GRADE -W EXISTING WATER SERVICE -G EXISTING GAS SERVICE -6. H. W- OVERHEAD WIRES TEST PIT {� BENCHMARK N e 2 ELO Jae Bannister Lane LOCUS m S Z ° Howes Rd $ fC ram.• s � a m io CL a. a Cpippial LOCUS MAP NOT TO SCALE GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: -310 CMR 15.405(1)(b)&(h): 1) A 12' variance, S.A.S. to crawl space (locus), for an 8' setback. 2) A 1' reduction to the required 5' separation between maximum seasonal high groundwater and bottom of S.A.S., for 4' sepataion. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO PRIVATE WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL. PROPOSED SEPTIC SYSTEM UPGRADE PLAN 50 HOWES ROAD, SOUTH YARMOUTH, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 Engineering by: Survey Review by: SCALE DRAWN JOB. NO. Engineering Works, Inc. JCEngineering, Inc. 1 "=20' P.T.M. 160-18 12 West Crossfield Road 2854 Cranberry Hwy. Forestdole, MA 02644 E.Wareham, MA 02538 DATE CHECKED SHEET NO. (508) 477-5313 (508) 273-0377 5/21 /18 P.T.M. 1 Of 3 r EXISTING SEPTIC TANK & NOTE: TO PREVENT BREAKOUT, FINAL GRADE PROPOSED PUMP CHAMBER SHALL NOT BE AT, OR BELOW, EL.=99.6 PROVIDE RISERS & COVERS AS DESCRIBED: FOR A DISTANCE OF 15' FROM THE EDGE 1) SET ALL COVERS TO 6" OF GRADE UNLESS NOTED IN N0. 2 PROPOSED D—BOX OF THE PROPOSED S.A.S. 2) 20" OUTLET COVER OVER ZABEL FILTER & PUMP ACCESS MANHOLE INSTALL WATERTIGHT RISER & PROPOSED S.A.S. COVER SET TO FINISH GRADE AND SHALL BE SECURED TO PREVENT COVER SET TO 6" OF GRADE INSTALL INSPECTION PORT OUTSIDE DRIVEWAY FOOTPRINT UNAUTHORIZED ACCESS. F.G. EL.=101.0 F.G. EL.=100.7t F.G. EL.=1QO.4(MIN.) to 100.6f (EXISTING) e MAINTAIN 2% GRADE (MIN.) OVER S.A.S. F.G. EL.=101.0t PROVIDE ENOUGH WI 4" DIAM. INSPECTION PORT, SLACK TO REMOVE PUMP L - $'(ce) — PERFORATED IN S.A.S., SOLID ® S=1%TO�MIN 2 SCA gs cK5 ®°sCH40 PVc1 SCH 40 PERF. PVC DISTRIBUTION LINES SET TOABOVE BOVE SWITHINWITH OFCRE GRADE.CAP 4"SCH40OP EL.=99.17 pROV1 AT ALL BEND a CAPPED ENDS 6" '� 6" EFF.DEPTH 10" INV.=99.28 I SLOPE OF PERF. PIPE = 0.5% INV. EL.=99.00(END) INV.=99.45 14 IN�'S ARE TO BE14p 40' EFFECTIVE LENGTH 98 SCH 40 PVC # HIGH G.W. pROPOSED D—BOX GAS1000 CAL EFFLUENrJ soo cAL EL.=94.5 SOIL ABSORPTION SYSTEM (PROFILE) rFl��LTER 3 OUTLETS (MIN.) BAFFLE (ZABEL OR EQUAL) INV.=97.75f INV.=99.20 EXISTING 10W EL.=93.50 SEPTIC TANK INV.=97.75 INV.=98.25f EFFLUENT FILTER SHALL BE INSTALLED ON OUTLET ESTABLISH VEGETATIVE COVER EXISTING TEE AS MANUFACTURED BY ZABEL OR EQUAL. FILTER (FIELD VERIFY) SHALL BE INSPECTED AND CLEANED ANNUALLY. (See Pump Detail, Sheet 3 of 3) FINISH GRADE 1000/500 GALLON SEPTIC TANK/PUMP CHAMBER EL.=100.4 to 100.6t 10 TANK BREAKOUT E EV =99.6 FAPPROVED NOTES: EL.=99.4kEND) t'' Y" ILTER FABRIC 1 SEPTIC TANK PUMP CHAMBER & D-BOX SWALL BET/LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH BOTTOM ELEV.-_ 98.50 3/4"-1 1/2" DOUBLE 4' MIN. SEPARATION TO G.W.73'5.5 7737'WASHED STONE CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). (WITH VARIANCE) 2) INSTALL INLET & OUTLET TEES AS REQUIRED. AND 4' OF NATURALLY 11.5' EFFECTIVE WIDTH 3) MAX. COVER OVER SEPTIC TANK, D-BOX & S.A.S. SHALL BE 36". OCCURRING PERVIOUS SOILS SOIL ABSORPTION SYSTEM (SECTION) 4) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR EST. HIGH G.W. EL: 94.5 TO CONSTRUCTION. 5) EFFLUENT FILTER SHALL BE INSTALLED ON OUTLET SEPTIC SYSTEM PROFILE TEE AS MANUFACTURED BY ZABEL OR EQUAL. FILTER SHALL BE INSPECTED AND CLEANED ANNUALLY OR MORE FREQUENTLY, AS REQUIRED. DESIGN CRITERIA NUMBER OF BEDROOMS: 3, 2 (HOUSE) + 1 (IN—LAW) SOIL TEXTURAL CLASS: CLASa IMIN/IN DESIGN PERCOLATION RATE: DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF /4 �ru/5r EXISTING SEPTIC TANK: 1000 GALLON CAPACITY PROPOSED SEPTIC TANK/PUMP CHAMBER: 1000/500 GALLON PROPOSED D—BOX: 1 INLET, 3 OUTLET (MIN.), H-10 INSTALL AN 11.5' x 40' LEACH FIELD SIDEWALL AREA: NOT APPLICABLE BOTTOM AREA: 11.5' x 40' = 460 S.F. TOTAL AREA: ..................................... 460 S.F. LEACHING CAPACITY = 0.74 GPD/SF x 460 SF = 340.4 GPD SHED I 59.5' 48.0' I 1 i 1 .(LU o i 10 (EXISTING f i 0 1 'HOUSE(#50) 1 a 1 T. O. F. =101. 3f �--_20-0'f-:l SOIL LOG DATE: MAY 2, 2018 SOIL EVALUATOR: PETER McENTEE PE(SE#1542) WITNESS: PHIL RENAUD IRS HEALTH AGENT ELEV. TP DEPTH 101.2 A 0 11 LOAMY SAND 10YR 4/2 100.2 12" B LOAMY SAND PERC S.A.S. LAYOUT 10YR 5/8 16 /34 98.2 3g'; C MED. SAND 2.5Y 6/4 94.5 STG. G.W. = 80" ADJ. G.W. 94.0 86 PERC RATE <2 MIN/IN. "B&C" HORIZONS STANDING G.W. @ 80", (EL.=94.5) INDEX WELL, MIW-29, ZONE A,WATER LEVEL=5.53, ADJUSTMENT=O', APRIL 2018 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 50 HOWES ROAD, SOUTH YARMOUTH, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 Engineering by: Engineering Works, Inc. 12 West Crossfield Road Forestdole, MA 02644 (508) 477-5313 Survey Review by: KEngineering, Inc. 2854 Cranberry Hwy. E.Wareham, MA 02538 (508) 273-0377 SCALE N.T.S. DRAWN P.T.M. JOB. NO. 160-18 DATE 5/21 /18 CHECKED P.T.M. SHEET No. 2 of 3 I PROVIDE WATERTIGHT CONCRETE RISER WITH SECURED FRAME & COVER TO GRADE HOISTING CABLE 7x19 STAINLESS STEEL 1 /8" DIAMETER. / 1,760 LB. STRENGTH. PROVIDE ENOUGH WIRE SLACK TO REMOVE PUMP I� INV.(IN)=98.00 J ALARM ON EL: 95.30 PUMP ON EL: 95.13 NEMA 4 JUNCTION BOX CORROSION RESISTANT & LIQUID —TIGHT CABLE CONNECTORS SUPPORTED BY 1-1/4" PVC CONDUIT. JOINTS TO BE MADE WATERTIGHT. USE SJE RHOMBUS—JB PLUGGER OR EQUAL. PROVIDE ENOUGH WIRE SLACK TO REMOVE PUMP INSTALL 1' PVC CONDUIT TO HOUSE FOR WIRING WITH WATERTIGHT JOINTS. WIRE HIGH, WATER ALARM FLOAT TO SJE RHOMBUS TANK ALERT XT ALARM PANEL ON CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. 2" BALL VALVE (FIELD ADJUST FOR 20 GPM RATE) (INSTALL QUICK DISCONNECT FOR EASY REMOVAL) 2"SCH. 40 DISCHARGE (THROUGH RISER -SEE PROFILE) 2" 90- ELBOW W/ 1 /4" WEEP HOLE FOR SELF -DRAINING FORCE MAIN BOTTOM OF PUMP OFF EL: 94.46 2 1 U"- — 2" SWING CHECK VALVE PUMP CHAMBER 8" 2" SCH. 40 PVC DISCHARGE PIPE ELEV.= 93.50 ADDITIONAL 3/16" VENT HOLE (MIN.) ABOVE PUMP FLANGE PROVIDE 2 FLOATS: 3.5"t (TO PREVENT PREMATURE PUMP BURNOUT) FLOAT NOA: PUMP ON/OFF—SJ RHOMBUS (PROVIDED WITH PUMP) FLOAT NO.2: ALARM ACTIVATION FLOAT —PROVIDED WITH ALARM PANEL LIBERTY LE40 SERIES PUMP .4 Ill 5 V (ON SEPARATE CIRCUIT FROM PUMP SPECIFIED) WITH 2" DISCHARGE, OR EQUAL PUMP AND ACCESSORIES AVAILABLE AT: CAPE COD WINWATER WORKS CO., HYANNIS, MA. (508) 862-0166 NOTE: APPROVED ALTERNATE MAY BE SUBSTITUTED. PUMP DETAIL DOSING & STORAGE REQUIREMENTS DESIGN FLOW: 330 GPD DOSING REQUIRED: 4 CYCLES/DAY (SAND) 330 - 4 = 82.5 GALLONS/CYCLE DISTANCE REQUIRED BETWEEN PUMP ON AND PUMP OFF FLOATS: 82.5 GAL/CYCLE _ 125 GAL/FT = 0.66 FT/CYCLE (SAY 8") STORAGE REQUIRED ABOVE WORKING LEVEL: 330 GALLONS STORAGE PROVIDED: INV.(IN) EL: 98.00 - PUMP ON EL: 95.13 = 2.70' STORAGE PROVIDED = 2.70 x 125 GAL/FT = 337.5 GALLONS 0'-2-1 /2" 10'-2-1 /2" 3 x 12 VENT INLET > 5 TO 6 ITT — 20"(TYD A• COVERS BUOYANCY CALCULATIONS OPENING ��- I OUTLET I I I I 5-3-1/2" 3" I) COMPARTMENT A I I I I A 1000 GALLON MONOLITHIC PUMP CHAMBER I (WALL AVAILABLE 6'-1/2" I I I \ I I BOTTOM OF UNIT EL.= 93.50 54-1/2" 48' I I(1/3 CAPACITY) 51-1/2" REINFORCING RIB LIQUID LEVEL 3 �+ (DI HIGH GROUNDWATER EL.=94.5 I I O I I OI I BUOYANCY FORCE PER FOOT OF DEPTH: 3-1/2" I I I I I I 10.2' x 6.0' x 1' x 62.4 lbs./cu.ft. = 3818.9 Ibs. I I I MAX. DISPLACEMENT = 94.50 - 93.75 = 0.75' MAX. UPLIFT PRESSURE = 1.00' X 3818.9 Ibs/ft = 3818.9 Ibs. 9'-11-1/2" �10„ 4" KNOCKOUTS ,7„J WEIGHT OF UNIT EMPTY = 11,005 Ibs. CROSS SECTION A -A (TYPO PLAN VIEW 11,005 Ibs > 3819 Ibs O.K. SPECIFICATIONS 1.) CONCRETE 4,000 PSI AFTER 28 DAYS. 2.) CONSTRUCTION CONFORMS TO DEP TITLE V REGS. 310 CMR SECTION 15.226. 3.) REINFORCEMENT PER ASTM C1227-93. APPROVED ALTERNATE MAY BE USED. 1000 GALLON MONOLITHIC PUMP CHAMBER WIGGIN PRECAST CORP MRDEL#1500MONTH I 4" TOP WEIGHT = 11,005 IBS. HEAVY TOP WEIGHT = 13,966 IBS. PROPOSED SEPTIC SYSTEM UPGRADE PLAN 50 HOWES ROAD, SOUTH YARMOUTH, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 Engineering by: Engineering Works, Inc. 12 West Crossfield Road Forestdale, MA 02644 (508) 477-5313 Survey Review by: JCEngineering, Inc. 2854 Cranberry Hwy. E.Wareham, MA 02538 (508) 273-0377 SCALE N.T.S. DRAWN P.T.M. JOB. NO. 160-18 DATE 5/21 /18 CHECKED P.T.M. SHEET NO. 3 Of 3