Loading...
HomeMy WebLinkAboutEngineered Plan - 1996N ASSESSORS MAP: 28 PARCEL: H49 FLOOD ZONE: C Igz LOCUS 0 t� c, vc b LOCATION MAP LOT 49 12,260 ± S.F. (028 ± AC.) +s. s 40.6 � �10. 6 f0 �I N 121. 569 BENCHMARK AT WATER CATE ELEV. 10.6 t 10' MIN 2r-(20' MIN) r N S.T. 1o' i 1 lg- ... 9. 5 MIN ►� 9.3 1 8 9 1 10. 4 INv - / 'y 'CP1 1 BRICK (CRAWL EXISTING W PATIO SPACE) 3 BEDROOM Dp/ELLING , o o 1st FLR - 1 (FULL BASE.)o iy N G i AS METER �f0. f 7c woww PAVED DRIVE 10.1 -11 O IN GASCATE bLj � b tts 0 Im b 123. 65' c j \ N \ 9 / 10 4.9 I t9. 9 KEY: EXISTING CONTOUR: - PROPOSED CONTOUR: ......••••••••••••••••.•••••.. EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25 TEST HOLE: •$�- UTILITY POLE: -0- FENCE LINE: ---- HYDRANT: -6 RETAINING WALL: TREE: m DEMAREST-McLELLAN ENGINEERING 24 SCHOOL STREET P.O. BOX 463 HEST DENNIS, MASSACHUSETTS 02670 PHONE & FAX : (508) 398-7710 DM # 96_077 (D19F15) TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 6-13-96 PERCOLATION RATE: < 2 MIN/IN TH-1 TH-2 9.4 A/E HORIZON ` ELEV. LOAMY SAND f0" 10YR 2/1 8B B HORIZON LOAMY SAND 20" fOYR 4/6 7.7 C HORIZON MEDIUM SAND z.5Y 6/8 NOTES: 1. VERTICAL DATUM. ASSUMED FROM QUAD (NGVD +f-1 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO H-10 LOADING SPECIFICATIONS. 5. PIPE PITCH = 1/8" PER FOOT, (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D-BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO 72" 3.4 EXCEED 3.0'. 78" 2 11. EXISTING CESS POOLS TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 12. ALL UNSUITABLE SOIL (A & B HORIZON) WITHIN 5' OF LEACHING AREA USCS GROUNDWATER ADJUSTMENT: TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. WELL. Mrw-zs, ZONE: A. ADJUSTMENT (8 OUT OF 10 YR HIGH): or 13. D-BOX TO BE WATER TESTED .TO ENSURE LEVELNESS AND EQUAL FLOW. SEPTIC SYSTEM DESIGN FLOW ESTIMATE:. 3 BEDROOMS AT 110 GAL/DAY/BEDROOM = 330 GAL/DAY SEPTIC TANK. 330 GAL/DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE ONE LEACH FIELD (22' x 219 SIDE AREA.' NA (.74) = GAL/DAY zr z' BETWEEN PIPE AND EDGE OF. FIELD 22' 6' BETWEEN PIPES BOTTOM AREA: 22' x 21' = 462 SF (.74) = 342 GAL/DAY _.,T_OT_AL-CAPAG'ITY_-= 342 GAL/DAY SEPTIC SYSTEM SECTION 2" PEASTONE 3 f 4" - 1 1/2" COVERS WITHIN 12" OF FINISHED GRADE WASHED STONE 12.5 ONE INSPECTION COVER FIRST FLOOR fro BE 1�ITHIN 6" OF GRADE) �v� 4" PERFORATED Ir F PVC PIPE (EXISTING ELEV. 8.9 TO BE RAISED 0.6'), REQUIRED TITLE FIVE VARIANCES 1. SECTION 15.212: LEACHING AREA TO BE 4.17 ABOVE ADJUSTED GROUNDWATER. 2. SECTION. 15.240 (9): 6" OF COVER OVER LEACH FIELD. (SYSTEM HAS BEEN DEIGNED TO MAXIMUM FEASIBLE COMPLIANCE) �- ELEV. 9.1 91 8.1 925 1500 GAL ELEV. ID -BOX 885 21' ELEV. ELEV. SEPTIC TANK 902 (6" OF ELEV. (6" OF STONE UNDER OR ELEV. STONE ONE LEACH FIELD MECHANICALLY COMPACTED) UNDER) 8.7 (22' x 21' x 6" DEEP) GAS BAFFLE AT ELEV. TEE SIZES: OUTLET TEE INLET: 6" UP, 13" DOWN ADJUSTED GROUNDWATER ELEV.= 4.1 �w OUTLET: 6" UP, 14" DOWN AP ROVED BY: DATE: JOHN Z. �CiV4L 4' THOMAS McLELLAN, P.E. JOHN Z. IJIMAREST SITE AND SEWAGE PLAN LOCATION 15 NANTUCKET ROAD SOUTH YARMOUTH PREPARED FOR- A.B. CANCO f W I LLI AM T ELFORD SCALE: 1" = 20' DATE: 7-8-96 REFERENCE: PLAN BOOK 97 PAGE 57 1