Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDE-19-000130
A Commonwealth of Official Use Only - - E a;► Massachusetts Permit No. BLDE-19-000130 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked (Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:7/9/2018 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to periorm the electrical work described below. Location(Street&Number) 153 CENTER ST Owner or Tenant NORRIS PIPPA Telephone No. Owner's Address 36 ASH ST APT 402,CAMBRIDGE,MA 02138-4868 Is this permit in conjunction with a building permit? Yes ❑ No ❑ (Check Appropriate Box) Purpose of Building Utility Authorization No. / Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters 1�J New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system.(16 Panels 5.12 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ElNo.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: HeaterstSians Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE ❑ BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Michael J Leblanc Licensee: Michael J Leblanc Signature LIC.NO.: 17423 (If applicable,enter"exempt"in the license number lute.) Bus.Tel.No.: Address:16 Westwind Cir, Osterville MA 026551375 Mt.TeL No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) ❑ owner 0 owner's agent. Owner/Agent Signature Telephone No, PERMIT FEE:$150.00 20,s (,tom I„INwJ e/c418 K * //�� q�/ ` ♦ • l�ommanwea�o`rr/aaeac�elta Official Use Onl 1 6:79.'"--V 30 y ,-.-�,p��f E/ cc� �c77 ((�� Permit No. 'diel.= ` .LJePadmenl o�Jiro Serviced *L-----,-----/4 , BOARD OF FIRE PREVENTION REGULATIONS Rev.1/07]yandFee lank)Checked (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 06/28/2018 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. n Location(Street&Number) 153 Center St. Yarmouthport `-'"'r----ja I Owner or Tenant P i p p a Norris Telephone No. g57-445-9105 Owner's Address \_______.„ o � Is this permit in conjunction with a building permit? Yes ❑X No ❑ (Check Appropriate Box) Irn lw 1/4 \ Purpose of Building Residential Utility Authorization No. I J II Existing Service 2 0 0 Amps 1 2 0 '240 Volts Overhead ❑X Undgrd❑ No.of Meters1 S ' ` I New Service _ Amps / Volts Overhead 0 Undgrd ❑ No.of Meters UJ r Number of Feeders and Ampacity 5.12 KW Solar System M ct Location and Nature of Proposed Electrical Work: Wiring of 16 roof top solar panels Completion oldie following table may be waived by the Inspector of Wires. No.o ' - • sed Luminaires No.of Ceil:Susp.(Paddle)Fans Transformers KVA No.of Luminaire Ou No.of Hot Tubs Generators KVA . No.of Luminaires Swimming Pool Above ❑ In- 0 No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.o :' Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burn No.of Detection and Initiating Devices No.of RangesNo.of Air Cond. otal• No.of Alerting Devices No.of Waste Disposers Heat Pump Number_ Tons No.of Self-Contained p Totals: "' —' -"'-' Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW ' ot❑ MunicipEl fie, "'4 Connection No.of Dryers Heating Appliances KW Securet s:* of stemis orr Equivalent J No.of Water KW No.of No.of Data Wiring: C Heaters Signs Ballasts No.of Devices o uivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications ' 'n No.of Devices or Equi end % — OTHER: — Attach additional detail if desired,or as required by the Inspector of Wt . L.. Estimated Value of Electrical Work: (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless `I the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The N undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. 4- FIRMNAME: Solar Rising LLC LIC.NO.:17423A Licensee: Michael LeBlanc Signature / LIC.NO.:30750 E C (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.•508-744-6284 " Address: 16 Wectwind Circle Osterville MA 02655 Alt.Tel.No.: 774-270-4125 *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner ❑owner's agent. Owner/Agent PERMIT FEE:$ Signature Telephone No. • 1 t • JURISDTCTIONAENOTES: GUVERNING-CODE• ' ALL AVID SHALL CONFORM TO THEFIXUONING WOES a 2015 INTERNATIONAL BUILDING CODE b. 2015 INTERNATIONAL RESIDENTIAL eT a 2017 NATIONAL ELECTRICAL CODE d. ANY OTHER LOCAL AMENDMENTS SHEET INDEX: COVER SHEET PV 1.0-SITE PLAN S 1.0-MOUNT DETAILS E 1.0-ELECTRICAL DIAGRAM E 3.0-WARNING LABELS E 4.0-WARNING LABEL LOCATIONS 7g irr-PTfr a '—w.• ■ - GENERAL ELECTRICAL NOTES: GENERAL STRUCTURAL NOTES: 3. t r- �a _e r"-Y r-•,,: 1. ALL WRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL a THE SOLAR PANELS ME TO BE MOUNTED TO THE ROOF FRMING USING 1 LL-"1 t.4 -• ei' 441�_ ,IL_-jF. - MEANS DESIGNED MID USTED FOR SUCH USE.FOR ROCFMOUNTED THE SFM SYSTEM BY UMW.THE MOUNTING FEET ME TO BE SPACED AS parer i --I`�: _ T ([�,i•E+ SYSTEMS.WIRING MUST BE PERMVIENTLY AND COMPLETELY HELD OFF OF SHOWN N THE DETALS,AND MUST BE STAGGERED TO A�MffM FRAMING �Ja. `,' `t i�. 41 i i- - F- r THE ROOF SURFACE MEMBERS TO SPREAD CMT THE ADDMONAL LOAD. 0.14- �,ry<�� �QJj�. 1.-,. 2. ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE L. UNLESS NOTED OTHERWISE,MOUNTING ANCHORS SWILL BE Xe LAG . fT ^- d€ii -t" -.�`�, CORRECTED ON INSTALLATION. SCREWS WITHAMWNUM OF2J4-PENETRATEN INTO ROOF FRAMING. �tl .:'t-.W r ;k :, Qi- Y • I J},� 3. SYSTEM SHALL BE INSTALLED N ACCORDANCE WITH ALL RELEVANT CODE a THE PROPOSED PV SYSTEM ADDS 2E pM TO THE ROOF FRAMING SYSTEM. LHS._ �ij°N'- �'•�"'t `'ss_re2.v.,i„.Z' -F7 4. RMP SHUTDOWN INMATES TAKES PLACE WITHIN THE FIRMWARE OF THE d. ROOF LIVE LOAD=20 psi TYPICAL.0;ASUNDER NEW PV SYSTEM. �-� ,^ate. p;p f .!! e,p INVERTER.RID SHUTDOWN COMMENCES UPON LOSS OF UTILfIYSWRCE.. GROUND SNOW LINO=30IOM p^,..n..,,.4 ♦' • VOLTAGE I. WIND SPEED•140 nigh I -'tie-O ♦ Fr tpze ,t, -: 5. SEE'E1.OAND-E2D FORDIAGRAMS.CALCULATIONS,SCHEDULE ANDEOD'OSUE CATEGORI'=B i Y' :1 �N'.; SPECFICATPNS. s Vivirlt.SOlar 1 A 1� 1800 ASHI18BLVD.L6H1,U(,86043 -!fes ,},_��,. »t"`tau,,=. `, 18774044128 'JillR '�A: ..1t� Y. 'A4, MA LICENSE: HIC-170848, d4 lT r f,�y� ME-15688A.SS-002342 I , ?It ~" etwk' t' .� -'_ • ` ',: PHOTOVOLTAIC SYSTEM SPECIFICATIONS: GOULART RESIDENCE 1 P. 1.15 t17H-+t . L - - 4 , C 39 GLEASON AVE p. .t.>y�,y.Ia : L �' ..., tm _, r, " SYSTEM SIZE-8.260kW DC 17.600kW AC YARMOUTH,MA 02801 r-t1' sl .,.I• ;$+'Gi4 `':� MODULE TYPE&AMOUNT-(26)JINKO SOLARJKM295M-60B UTILITY ACCOUNT114385660050 „cl IrEL,-.,m�'- ,.• MODULE DIMENSIONS-(L@VIH)64.97'139.0611.57' i INVERTER-(1)SOLAREDGE 7600H SERVICE F13083 •`4644 " ,u. - S. '' ,!': ' x INTERCONNECTION METHOD-LOAD BREAKER , MALS CENTER ,. COVER i 's �A K I _. ' ya4. � ,_it;, , BT:5a3,1. SHEET 1. ` _ %F' :N4* . 'N _ . 4.444 pUWNBY 5913081 P. f • S 0,0' SL p SLOPE SYSTEM LEGEND ® #1)14 MODULES AZIMUTH-180 PV SYSTEM SIZE: MATER ® #2)14 MODULES AIIIGGUE-cow NEW 8160&W DC I ;EMIAC ( SLOPE-28 E 11NG EXTERIOR MU1 SERVILE PMELTEO AZIMUTH-0 M TOWNS UERAfnuu131. MATERIAL•COMP COLE DUSTING MELDS SUJPMEL S POW OF OPE-13 Lij NIERCOINECICN. UTH-0 NEW PV SYSTEM AC DUCOMECT.EXAM MATERIAL-COMP ® Wmw 100E B . SHINGLE - 1 NEW PV SYSTEM INVERTER WARD:1X 760011. RED MAPPED. 25 NEW JEW SO .NM2OIM-&W MODLLES. O NEW SOAR EDGE MOOPIPASERS.MONIED $ ON THE MCNCF EACH MODULE NEW PV CONDUT RUN SEEEEI 0 CONOIT SCHEME r E%IFRKK RUI �ALIIC RLN ® 7 Co#CV NEW ANCDCM BOX WOWED TO FNMOCULG O77M 0 j O O i 5 Q A �/ iA � / rx w N.\ N\ \ lzz 0 co CD LU J 0 o M o vivint.Solar Lc 1 871404 4129 GOULART RESIDENCE 39 GLEASON AVE YARMOUTH.MA.02601 UTEUTY ACCOUNT It 14365880050 ASITE PLAN 5REGOML ' ' - OPEMINGCFNIEN YAW PV1.0 DATE 5232015 SCALE:3116'=t'-0' ,D0.AYM BY.5013063 1 • • l MOUNTING LEGEND t SAY , .. \ i ' 111 �� 4 SFM-9"ATTACHED SPLICE tai , - (jr — 51.0 'donor-al Mato Por i a E -✓ __ SFM-TRIMRAIL WITH . 1 SFM-ROOF ATTACHMENT 2 SECTION VIEW 3 ROOF ATTACHMENT 3 SFM-3"RAIL 51.0 KRTUKMl 51.0 .nrroswl 51.0 "°11°1°11 51.0 En10yNE ss rAn.am aaa w.v1a ", A\\ ILSCO SGB-9 GROUNDING LUGS I"'ll"'I .s. .on.. 11111111 s.: VIII �mv... � Air /. iirli .1:11 pos.ma.o .s1 .0 •MODULES IN PORT!MNDSPACE <%%. 6 SFM LAYOUT ,,,,,,,, ��-9'SPLICE 510 orroxwl ®, .mro SCALE 1 �1/3 Oft ` vivint.Solar04 1 877.404 4129 s+ A l7 N ,I !1 Tit— .e. GOULART SONRESIDENCEAVE IOYI �F fUYI 39GLEPSON.0 M YARMOUTH.MA 3653 10 PV SYSTEM MOUNTING DETAIL 11 SFM-TRIMRAIL UTILITY ACCOUNT r.u1as15mso 3u .o.rouu 51.0 .mrosau wwva r \ SOME 3!81x43 MOUNT DETAILSRO;PERAMGCENTERALA03 S 1.0 DATE 525.2014 SCALE.NOT TO SCALE OPAwNer.5111093 • t 2 e Photovoltaic System Conduit Conductor Schedule(AU.CONDUCTORS MUST BE COPPER) DC System Are(Watts) 8260 Tag* Description Wore Gauge *of Conductors/Color Conduit Type Conduit See m o AC System Sore(Watts) 7600 1 PV Wire 10 AWG 2(V+,V-) N/A-Free Alr N/A-Free Air n 4 Total Module Count 28 1 Bare Copper Ground(EGC/GEC) 6 AWG 1 BARE N/A-Free Air N/A-Free Air fl c ia E m 22 THWN 10AWG 4I2Va,2V-)B/R EMT 3/4' 2 THWN-2-EGC/GEC 8 AWG l(GRN) EMT 3/4' a z F. 4 3 THWN-2 8AWG 3(111 112 IN)B/R/W EMT 3/4' C -i u 3 THWN-2-EGUGEC 8AWG 1(GRN) EMT 3/4' ' O a 4 THWN-2 3AWG 3(1111111N)B/R/W EMT l' - P2 m r i 4 THWN-2-EGC/GEC 8 AWG 1(GRN) EMT 1' n = 3 5 i.— CO CO 0 N C v. Se •> i. V 51 a o 0r- INSTALLERS NOTETA NEM ^DREAMERSDREERS TO BE USED TO solar See I- MMEROOM FOR PV BREAKER 2 & us en SE7600NUB 2_: ti •Conlwim toNISI Rapid Shutdown Pdnlol interconnection.Load Side ] cc a, 0.2 Paconnct, Editing 7OS.12102NNb cc uare° b22250 zaareD SA W 2-1 w m W222R0 SpuareeSub New hle with icon Disconnect . - y O 240V/4OA Panel Phase,wIN 1WA Main Olsconnect F F Ilnlus o Z 2 Z m r STRING 2.14 PV 1 3 —11— NEMAntw MODULES equivalent with SHEET W/OPTIMIZERS •_ "7 utmost 100A NAME: mminatiom 4 ® STRING 1.14PV t x 1 \ � m MODULE NERM4 function Boa l:0 40A rll O � W/OPTIMIZERS with lweve ble © B 0 SHEET � ] Groom Spmep'ml re...... I NUMBER: T _ 7 I I_ - F 1rElwr 2ewMODULESPERINVERTEP.e260 WATTS STC Mai- -Lac be EnIKK MA Rum GEC Die IS el Dscomtct AWG copper W a PV Module Rating @ STC Conductor Calculations m G Module Make/Model Lnko Solar IRM295M300 Wire gauge calculated from code art.310.15(8)(16)with ambient temperature calculations from Max.Power-Point Current(Imp) 91 Amps art.310.15(B)(2)(a). eel w I va va Max.Power-Point Voltage(Vmp) 32.0 Volts `e a is Open-Circuit Voltage(Voc) 39.7 Vpks For^On Pouf^drace ay we use the 90Y column am(6)11,the relevant ambient temperature a- z• adjustment,and raceway fill adjustment from 310.15(6)(16). i Optimizer Solar Ed:a P320 Short-Circuit Current(Isc) 961 Amps For'Off Roof"conductors we use the 75Y astral anpacity,or the 90T cerium ampadty with W c DC Input Power 320 Watts Max.Seues Fuse(OCPD) 20 Amps the relevant ambient temperature and raceway fill adjustments,whichever is less. 3 ma u DC Max Input Voltage 48 Volts Nom Max Power at STC(Pmax) 295 Watts The rating of the conductor after adjustments MUST be greater than,or equal to,thecontinuous ° m F a DC Max.Input Current 13.75 Amps Max.System Voltage 1000 UDC(UL/IEC) duty uprated output current 'n u. DC Max.Output Current 15 Amps Voc Temperature Coefficient -029 I %/C Calculation Example-Wire Rating(90'C)x Ambient Temperabre Adjustment x Conduit Fill 3 5 Max string rating inverter dependent.See SE document. Adjustment>x Continuous Duty Output Current Inverter Make/Mod& solar Edge 5E760ne-US AC Output Current According to art.690.8(B)(1I 3167 Amps (On Roof,Tag 2):10 gauge wire rated for 00a 40 A x L0.8(4 Conductors)=32 A Se 18.75 A CEC Efficiency 99 % Nominal AC Voltage 240 Volts (Off Rod,Tag 3):8 gauge wire rated for 50 A, 50A>•39.58A AC Operating Voltage 240 Volts THIS PANEL IS FED BY MULTIPLE SOURCES(UTILITY AND SOLAR) (OH Rad,Tag Q:3 gauge wire rated for 100 A, 100Ax39.58A I- - Cont.Max.Output Current 32 Amps (0 DC Max Input Current 20 Amps Rooftop conductor ampacities designed in compliance with art. O Short Circuit Current 40 Amps 690.8,Tables 310.15(6)(2)(a),310.15(B)(3)(a),310.15(B)(3)(c), N Max.Output Fault Current 40A/10 ms 310.15(8)(16),Chapter 9 Table 4,5,&9.Location specific temperature obtained from ASHRAE 2017 data tables. ASHME 2017- e� Highest Monthly 2%D.B.Design Temp.:29.1 t iii Lowest Min.Mean Extreme D.B.:-19.2'C e7 ni ni jiia OCPD Calculations e Breakers sized according to continuous duty output current PV circuit nominal current based off inverter continuous output current X(125jart 690.8(AII). o .m: 6 m Inverter 1:5E7600H-US Max Output•3167 A x 1.25(art 690 8(A)) - f o— =3958A<40A(0CPD) r system output current w/continuous duly•39.58<40A(System OCPD) c cc 1O W m as s.10 Other Notes 111 i i Q f •Designed according to,and all code citations are relevant to,the NEC 2017. SHEET •All Interior raceways carrying DC current shall be metallic. NAME: b m 2 •. SHEET NUMBER. N 41 • • • Conduit,Raceways,and 1-Boxes(Labeled Every 101 Per Plaques and Directories at the Service Equipment(MSP)and the 5E760I1H-US String 1 DC Disconnecting Means Per 690.53 m 2 690 31(6)(31&(4) Location of All System Disconnects Per 690.56(B)&705.10 HOT LTAIG DO P"-- g HOTOVOLTAH:DC POWER SOURCE OL4GONNE > S WARNING:PHOTOVOLTAIC POWER SOURCES w s • u SNC •IE ALSO SU'. DFROM'.s MAXMUYSTVOLG ' 4 4 z F •e. Interac[Ne System PoiMof lnttrconnection Per 690.56 R1•� 4 '' a• 'O •. SCA..+:w'd MAXIMUM CURRENT n1ag A a• W O C •O 'V`6 SNONM C7W0 CONVERTER MAXIMUM A PHOTOVOLTAIC AC POWER SOUR[ e. • y 4 RA?EDO CURRE E , al c • RATED AC OI3IPUT CURRENT131.6T s; r �„ '•' �lT. � ,',1V •` ��.P�L . 'o m r e NO16:OPERATNG AC.VOLTAGE`210 - o.„-; /ss- a4.r :1/1= jIETER T G YZ' '1 ..� a .`- SE76C0H-US String 2 DC Disconnecting Means Per 690.53 psi System Disconnects Per 690.I3(B) Jr �� {01L DO- �D •Cij R, -••• PNOTOVOZTNC DC POWER SOURCE ISCONN6 3 )(•}. "_tee• r HO":,l1 `-.e, X.-J PC POWER Ye PV SYSTEM DISCONNECTSMI MAXIMUM VOLTAG A400 .,, - .�r „�' MAXIMUM CURREN7aP7E DC T ShOC CO MAXIMUM RATE 0 CURRE 1 L All Disconnecting Means Per 69013(B)&690.15(D) ��� _-.._.. mac.,..�_. ELI�ASHOCK PV With gPX�nect ng Mhutdown.eansPer690.56(CI(]I(a led Within 3 ft of the ice RMWALS ON THE LWEAND LOAD SIDE SOLAR PV SYSTEM EQUIPPED o MALBE,ETIERGGEDYUKOPEH ff/SITTO N a6z WITH RAPID SHUTDOWN c Power Source W Back-[Dut Connection,Adjacent to fed Breaker Per 705 12 " =RNI=1e nUTTURN RAPID SHUTDOWN AlIDA E THSWITCH TO THE ��� 33 EV(C "OFF*POSITON TO Nrasas ^y V SHUTDOWN HAZARD M O AND REDUCE Rapid Shutdown Switch Per 690.56([)(3) SHOCK HAZARD , m Si RAPID-HUTDOWHS C F•' IN ARRAY sr cc el 9i 2f o— > z w ei w W „r a' a coo SHEET NAME: Ia C ` u -n 3 3 i SHEET NUMBER: ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8'WHITE ARIAL FONT TEXT,AND HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED. en ALL PLACARDS SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS.HANDWRITTEN SIGNS WILL NOT BE ACCEPTABLE. Mi • • • • • r C C MAIN BREAKER DE-RATED TO•^DUE TO SOLAR CM PHOTOVOLTAIC AC POWER SOURCE (Th PHOTOVOLTAIC DC POWER SOURCE DISCONNECT CIRCUITS �� RATED AC OUTPUTCURRENT:^'A MAXIMUM VOLTAGE:"A •'•-value ax calculated for m o MAX OF•••AMPS PV SOURCE ALLOWED NOM.OPERATING AC VOLTAGE:••••V MAXIMUM CURRENT:"V account,for specific value see the v DO NOT INCREASE MAIN BREAKER RATING Property of Vivint Solar DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT:"A previous warning label page Property of Vivint Solar C 1 Property of Vivint Solar c p 6 - WARNING 5 WARNING:PHOTOVOLTAIC POWER SOURCE vol O �� Property of Vivint Solar /, r^7v ��.ITE PLAN PLACARD SHOWING ADDITIONAL POWER SOURCE n P 'o 2 ELECTRICALSHOCK HAZARD U AND DISCONNECT LOCATIONS.PLACARD SHALL BE ' m TERMINALS ON THE UNE AND LOAD SIDES MAY BE 6 WARNING � '� ENERGIZED IN THE OPEN POSITION POWER SOURCE OUTPUT CONNECTION MOUNTED ON EXTERIOR OF ELECTRICAL PANEL m t, L Property of Vivint Solar �� DO NOT RELOCATE THIS OVERCURRENT DEVICE /\ Property of Vivint Solar 3 PV SYSTEM DISCONNECT Property of WNn15olar ICL PV rapid shutdown label 3 PropertydYmnt Solar /1 ClQ epwred by (`// RAPID SHUTDOWN SWR[H FOO SOLAR PV SYSTEM69056(q(1)ilMicated an E.3 Property of Vivint Solar S.. _CO 0 tra 4.: C LA IDM• IN ■■ IF APPLICABLE E ROOFTOP ARRAY 0 0 INSIDE PANEL INSIDE PANEL 0 9 o. S'. •r- EVERY 10'AND •,; Cp� 0 © © ©© 0 O 1 IF APPLICABLE 5 m © ': lb VIF APPLICABLE 9 w a, l�04, ,4`,Fe 2 ca o DC• O M wwz © ■ DISCONNECT -•-• _ — -- -- —_... E E 7 m • INSIDE los _ ? ? f FA SHEET SOLAR INVERTERS COMBINER PANEL VISIBLE/LOCKABLE VIVINT SOLAR METER VISIBLE/LOCKABLE SUB PANEL MAIN SERVICE NAME: luNR10N 0 (MAY BE ON ROOFTOP (WHEN USED) NC DISCONNECT (WHERE REQUIRED) NC DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL a w INTEGRATED WITH (WHERE REQUIRED) BOX ARRAY) TYPICAL SOLAR GENERATION INSTALLATION 3 3 e (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) SHEET ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT(DC)CONDUIT, NUMBER: BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8'WHITE ARIAL FONT TEXT,AND ENCLOSURES,RACE-WAYS,CABLE ASSEMBLIES,JUNCTION BOXES COMBINER BOXES,AND DISCONNECTS TO ALERT HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED.ALL PLACARDS THE FIRE SERVICE TO AVOID CUTTING THEM.MARKINGS SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT(3048 SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS.HANDWRITTEN SIGNS WILL MM),ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS OR BARRIERS. 7 NOT BE ACCEPTABLE. LAI AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. - This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Manufacturer: Jiaxing Pacific Energy Equipment Corp. No. 8 Haiwan Ave Address: 1411 Broadway Blvd NE Address: Hangzhou Bay Ddao New Area Albuquerque, NM 87102 Haiyan Economic Development Area Jiaxing City, Zhejiang Province Country: USA Country: China Contact: Klaus Nicolaedis Contact: Lili Zeng Phone: 505-301-3605 Phone: 510-979-1920 FAX: NA FAX: NA Email: klaus.nicolaedis@unirac.com Email: Izeng@ccmfg.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA 0/001112/1k, / Control Number: 5003278 Authorized by: OH_ for Thomas J. Patterson, Certification Manager TUS t Intertek � This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark Is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Chant.Intertek's responsibility and(lability are hnxted to the terms and conditions of the agreement Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any lose,expense or damage occasioned by the use of this Authorization to Mark Only the Client Is authorized to pent copying or distnbuhon of this Authonzabon to Mark and then only in its entirety.Use of Intertek's Certification mark is restncted to the conditions laid out In the agreement and In this Authorization to Mark Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark In accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL 2703 Issued:2015/01/28 Ed: 1 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels Product: Sun Frame Micro Rail Brand Name: Unirac Models: Unirac SFM ATM for Report 102393982LAX-002 Page 1 of 1 ATM Issued: 5-May-2016 ED 16.315(1-Jan-13)Mandatory 0o SrMIAILM • INSTALLATION GUIDE • i�py- TABLE OF CONTENTS - A-TOOLS&SPECIFICATIONS B-SYSTEM COMPONENTS C-SYSTEM COMPONENTS D-SYSTEM COMPONENTS E-SYSTEM LAYOUT F-THERMAL EXPANSION LIMITS G-FLASHING&SLIDERS H-1ST ROW INSTALLATION I-MICRORAIL INSTALLATION 1-MODULE MOUNTING K-FLOATING TRIMRAIL INSTALLATION DOCUMENT REVISION HISTORY-INTERNAL USE ONLY-DO NOT PUBLISH FOR PUBLIC RELEASE L-MICROINVERTER&WIRE MGMT- Publication Date Notes/Changes M-MICROINVERTER&WIRE MGMT. PUB2016APR26 Manual Release vv/SFM Tnmi ail'" N-FINISHING TOUCHES 0-SYSTEM BONDING&GROUNDING PUB2016M.AY31 Grounding Lug-Torque Changes&Wire Specifications P-ENPHASE SYSTEM MICROINVERTER GROUNDING PUB2016AUG15 Certified Module Revisions Q-UL CODE COMPLIANCE NOTES PUB2016AUG18 Updated Graphics and Module Wattage Table R-TESTED/CERTIFIED MODULE LIST PUB20171AN20 • Floating Trim Clips S-MODULE MAINTENANCE • System Layout&Span Rules T-CONSIDERATIONS&MAINTENANCE • Thermal Expansion • Tested/Cei tined Module List • UL Compliance Notes-Fire Certification for Flat Roof Applications PUB2017JAN20 sFm 000 fRAmE 00 srMRAILT. INSTALLATION GUIDE TABLE OF CONTENTS A-TOOLS&SPECIFICATIONS B-SYSTEM COMPONENTS C-SYSTEM COMPONENTS D-SYSTEM COMPONENTS E-SYSTEM LAYOUT F-THERMAL EXPANSION LIMITS G-FLASHING&SLIDERS H-1ST ROW INSTALLATION I-MICRORAIL INSTALLATION 1-MODULE MOUNTING K-FLOATING TRIMRAIL INSTALLATION L-MICROINVERTER&WIRE MGMT. M-MICROINVERTER&WIRE MGMT. N-FINISHING TOUCHES 0-SYSTEM BONDING&GROUNDING P-ENPHASE SYSTEM MICROINVERTER GROUNDING Q-UL CODE COMPLIANCE NOTES R-TESTED/CERTIFIED MODULE LIST S-MODULE MAINTENANCE T-CONSIDERATIONS&MAINTENANCE PUB2017JAN20 000 S FM FRAME TOOLS & SPECIrICATIONS A DO MICRORAILTM INSTALLATION GUIDE PAGE I_Eu. TECHNICAL SPECIFICATIONS: TOOLS REQUIRED OR RECOMMENDED FOR LAYOUT, SAFETY: AU applicable OSHA safety guidelines Material Types FLASHINGS & ROOF ATTACHMENTS: should be observed when working on a PV All extruded components: •• Hammer installation job site. The installation and handling 6005A-T61 or 6061-T6 Aluminum Marker/crayon of PV solar modules, electrical installation and PV • Measuring tape racking systems involves handling components Hardware:Stainless Steel • Drill with potentially sharp metal edges. Rules regarding Bonding and Grounding Integrated in • Pilot drill bit the use of gloves and other personal protective MicroraillM (Trimrail'TM and row to row bonding • Pry bar equipment should be observed. • requires additional components) String line TORQUE SPECIFICATIONS: TOOLS FOR MODULE INSTALL: ALL SFM Hardware 20 ft-lbs • Drill and socket adapter or socket wrench -- - • 1/2'socket Grounding lugs Per Page"0' • 1/4'hex driver • Torque wrench ODDs F mFRAME SYSTEM COMPONENTS B DO MICRORAILTM INSTALLATION GUIDE PAGE 3 3 i,,. z 3 .rori/oiiio Z z 1 1 mo 4 4/r. 47.--.4401/ /�� 4 �� t-rne , it,..., i 8 9 7r71 7 ,Il�/ / ice' At $ 9 6 ® r/e 4 5 ��c �• ib SUNFRAME MicrorailT"t-3" SUNFRAME MicrorailTM 9"Splice SUNFRAME MicrorailTM 9"Attached Splice Sub-Components: Sub-Components: Sub-Components: 1. 3'Base 1. 9'Base 1. 9'Base 2. 3'Cap 2. 9'Cap 2. 9'Cap 3. Clamp Socket Head Cap Screw 3. (3)Clamping Socket Head Cap Screws 3. (2)Clamp Socket Head Cap Screws 4. Bonding Pin 4. Bonding Pins 4. Bonding Pins 5. Helix 5. Helix 6. Tower Functions: 6. Tower 7. 6.75'Slider • 2,3 or 4 module support&connection 7. 6.75'Slider 8. Dovetail Lock • E-W module to module bonding 8. Dovetail Lock 9. Dovetail Bolt 9. Dovetail Bolt Features: Functions: • Arrives on-site preassembled and ready for installation Functions: • 1 or 2 module support to roof attachment • Cap indicates module height compatibility • Module to roof attachment(when attachment is necessary • Supports discrete module thickness from 32mm to at splice point) Features: 46mm • E-W module to module bonding • Arrives on-site preassembled and ready for installation • Receiving feature that allows simple module placement, • - Cap indicates module height compatibility tightening of fasteners and eliminates working over Features: • Supports discrete module thicknesses from 32mm to modules. • Arrives on-site preassembled and ready for Installation 46mm • Does not require attachment to roof • Cap indicates module height compatibility • Receiving feature that allows simple module placement, • Supports discrete module thickness from 32mm to • tightening of fasteners and eliminates working over 46mm modules. • Receiving feature that allows simple module placement, • + - tightening of fasteners and eliminates working over modules. • . o°° FRAME SYSTEM COMPONENTS E • • . • DO MICRORAIL'M INSTALLATION GUIDE PAGE FLOATING TRIM CLIP CHECK - i COMPATIBLE MODULE I IIII THICKNESS 1 �' _-_5.------'-- 3 4l 0?,,; • `\ SPLICE 7 ar,.... . 7,4' ,i LI /`` ,/_ VL-- If - 1 5 fil 32mm 35mm 40mm 46mm TrimrailTM Trimrailim Roof Attachment Floating Trim Clip Functions: Sub-Components: Functions: • Required front row structural support 1. Trimrail roof attachment • Attaches TrimrailTM to module when fewer than 2 rafter • Module mounting 2. Hex bolt and Tri-drive nut attachment points are available • Installation aid 3. Tri-drive nut • Aesthetic trim 4. Dovetail locks Features: 5. Square nut • Compatible with all Trimrail"profiles • Features: 6. Clamp bolt • Tool-less installation • Mounts directly to L-feet 7. 3'Slider • Aligns and captures module leading edge TrimraiLTM Splice • Available for various module heights Functions: • Supports discrete module thicknesses from 32mm to • TrimraiF"to roof attachment/flashing Functions: 46mm • Front row structural support Features: • Installation aid • Slots provide vertical adjustments to level array • Structurally connects 2 pieces of TrimrailTM • Slider provides north/south adjustment along the slope of the roof. • Features: • Aligns and connects TnmrailT pieces • Compatible with all TrimrailTM profiles • Tool-less installation O°osF mFRAME SYSTEM COMPONENTS o ©O MICRORAIL'" INSTALLATION GUIDE PAGE Wire Bonding Clip w/8AWG 141ei Alternate Or".� Alternate Orientation at SC 'ter s ilo 41C . o'iub MLPE Mounting Assembly SFM Flat Flashing Wire Bonding Clip w/SAWG Enphase Engage Cable Clip Functions: Functions: Functions: • Patented roof sealing technology at roof attachment point • Row to row bonding • Securely attaches Enphase Engage cables to module • For use with compatiabile 3'&6 75'SFM Sliders • Module to Trimrailt"bonding flanges (See Unirac Master Price List for details) • Single Use Only • Allows three(3)mounting positions to suit any cable orientation Features: Features: • Integrated EDPM Rubber Bushing No fasteners required Features: • Manufactured by EcoFasten Solar • Resists sliding to reduce cable slack EcoFasten Solar' MLPE Mounting Assembly Functions: • Securely mounts MLPE to module frames • MLPE to module bonding _ Features: • Mounts easily to typical module flange • UL2703 Recognized MLPE=Module Level Power Electronics, e.g.microinverter or power optimizer • 0000 SUN FRAME SYSTEM LAYOUT U DO SFM MICRORAILT" INSTALLATION GUIDE PAGE t I ' 1 ;l - - - 1. Determine appropriate array Location * L 0 -0 <1'. f on roof.NOTE:Consult local AHJ regarding I =i `# 1 setback requirements 1 I. 1 2. Select starting course of shingles (or 1 , 1 tiles) 1 i i 1 _ 0......... _"��+ C C,. ,,., m 3. Mark next row of attachments and repeat for remaining rows 1 ; 1 1 1 ; 1 NS distance equals module width+1' 4. Locate 1st rafter closest to array edge I I i 1 1 0 (and inside array footprint)and mark I ( ® a 7i 5.Find next rafter far attachment based on I .� 11 J appropriate span IIF 4 I -Continue to end of array 1 I Mark Last rafter before end or array '-- El Span rt 6.Mark attachment points on rafters along TO STAGGER ATTACHMENTS:Shift each subsequent g 1 row of attachments one rafter over. L- each NS module rid Line 7. Refer to Unirac SFM D&E Guide and 4 U-Builder for allowable spans and cantilevers. I Li—4 See the Design and Engineering Guide for details on regional max spans and overhang. DEop sFm FRAME THERMAL EXPANSION LIMITS LI 00 MICRORAIL'M INSTALLATION GUIDE PAGE NORTH-SOUTH THERMAL EXPANSION LIMITS: j • 12 Rows of modules-Landscape orientation • 7 Rows of modules-Portrait Orientation EAST-WEST THERMAL EXPANSION LIMITS: . 71- • 33ft.with no module gap(butted modules) MAX ROWS • 100ft.with a minimum module gap of 1/8" LANDSCAPE=12 --- - PORTRAIT.7 al VN/S GAP SET INSTALLED E/W BY SFM SYSTEM -► MODULE GAP GEOMETRY 0.0'TO 1" I. MAXIMUM EAST/WEST ARRAY E.TRIMRAIL LENGTH NO GAP BETWEEN MODULES:33 FEET - _ - 0.1'to 1'GAP BETWEEN MODULES:100 FEET • • • 0ODo S Fms,Rujilii, FLASHING & SLIDERS 0 " DO MICRORAILTM INSTALLATION GUIDE PAGE —LQ_l___ 1 I I k+' I — INSTALL SLIDERS AND —ROOF RIDGE- 1_ ��� ROOF ATTACHMENTS: h� � 9 Follow manufacturer instructions r._�' for flashing Shing installation procedures • PILOT HOLES: Drill pilot holes for lag FLASHINGS:Place flashings 0% screws or structural screws(as necessary) Mod NS+1" • • • r . r QIP - — - ./P -4='W NOTE: If N-S module edge is within 1"of the • • shingle course above,you have the option to 4\ •R'%. pivot/ rotate slider at the attachment point • • r • �J�► to span the next course and cut shingles as required. drib n Cut Shingles as Required >-....-----.-----..."---., Mod NS+1" Rotate Slider .---"---„,,,... __ n \ 1 ____J in-Less MODULE EDGE _ Than 1"- S INSTALL SLIDERS AND TRIMRAIL ROOF ATTACHMENTS: • Insert flashings per manufacturer instructions s NOTE:Use Lag screw or structural fastener with a maximum diameter of 5/16" • Attach sliders to rafters EAVE — • Verify proper row to row spacing for module size(Mod NS+ 1") n • Ensure that TrimrailT" roof attachments in each row have sufficient — J L engagement with slider dovetails for proper attachment. ��V// ®°osF MFRAME 1ST ROW INSTALLATION 0 DO MICRORAILTM INSTALLATION GUIDE PAGE moi ;; ALIGN FRONT ROW: TIGHTEN SLIDER: TRIMRAIL PREPARATION: Align front row TrimrailT" roof attachments with Tighten front row lag screw and Trimrail" roof Determine overall Length of TrimrailT"for front row. string Line attachments dovetail clamp bolt. Determine splice locations (if any) and Trimrail lengths required.When 2 or less attachment points TIP: Pull String-line across back (smooth) edge of are available at front of module edge, a Trimrail attachments floating clip may be required,see page(K)for details. _.....„....-------7:4,[ L INSTALL TRIMRAIL SPLICE BARS: Place TrimrailT"' ATTACH SPLICE BARS: While holding TrimrailT" with front side up and firmly insert splice bar into sections in alignment, join sections together with TrimraitT",until it clicks. splice bar centered at joint. Bonding between trim sections occurs through the splice bar. NOTE:Do not over-insert splice , See the Design and Engineering Guide for details on regional max spans and overhang. • 0©00 FRAME MICRORAIL INSTALLATION I .. . 4. 00 MICRORAIL' INSTALLATION GUIDE PAGE ti- \.iii, _ I - .ter ----,11-;,„i BONDING VIN •�. Y • ��ti 1 -� = SQA 1...±......._ _ TRIMRAIL ROOF ATTACHMENTS & TRIMRAIL ATTACH TRIMRAIL TO ROOF ATTACHMENT: Attach INSTALL MICRORAILS: Install remaining Microrails ORIENTATION: TrimrailTM roof attachment should rail using 3/8'hex bolt &Tri-drive nut and serrated at marked attachment points. Loosen dovetail have horizontal flange facing uphill for uniform row flange nuts. Make sure TrimrailTM is Level across all retaining fastener and push MicroraillM to top of spacing and ease of lag screw assembly.On first row, TrimrailTM roof attachments.After rail is Level,tighten slider.DO NOT SLIDE ALL THE WAY OFF SLIDER. position TrimrailTM with module catch side facing dovetail bolts to secure TrimrailTM roof attachments uphilL to sliders. NOTE: Bonding pin on Microrails should be postioned downslope. --- - --- -- - - --r ���-7--c�� i , > .���� _ aarainne =_._ a / . . 1 7 7 7 7 7 7 7 '7 7 7 7 7 7 .7 7 7 7 —7 " '7 '/ `/ '/ '7 ' '/ ` '7 ` ', -, DOD FRAME MODULE MOUNTING DO MICRORAILT" INSTALLATION GUIDE PAGE �s. a i;I\ ��' � - � tib _ il► r y _ _ LAY IN MODULE(S): Install first two (2) modules on LAY IN MODULE(S): Module should slide into catch SEAT MODULE(S): Ensure that modules are properly bottom row.Install downhill end of module into the feature of the TrimrailT". seated in top cap and base. TrimraiLT"first and then position uphill 3'microrails to support modules. Wire management is performed after each row of modules is installed. Refer to wire management section (pp.J & K) for detailed instructions. --- - - — ---- - .--Hiz.-41 ATTACH SPLICE:Attach splice at intersection of two FASTEN MODULES: Finish installing modules along TIGHTEN FASTENERS: Tighten fasteners to required (2)modules. row and tighten fastening bolts after entire row is torque. • Use attached splice if necessary. installed. • Ensure minimum module engagement using NOTE: Tighten components from the roof up, 0 indicator marks. Dovetail Bolt then 0 Clamp Socket Head Cap Screw 4 = OD FRAME FLOATING TRIM INSTALLATION a . DO MICRORAILTM INSTALLATION GUIDE PAGE —T ; - ; REQUIREMENTS FORTRIMRAILROOFATTACHMENTS I &FLOATING TRIM CLIP: I A� T" TrimraiLT" Roof Attachments shall be used at rafters Floating Trim Clip Trimrail Roof Attachment or Required Floating Trim Clip Acceptable nearest to outside edge of array. LI �� • Use Floating Trim Clip on the longest'frees side if p ,_je1� I only one(1)TrimraiLT"Roof Attachment is utilized. /_\ �' ' ' f I _ • Use of 2 Floating Trim Clip(s) without a Trimrailm �/s's.• I1 Roof Attachment is acceptable if the section of • ' iii N....._‘' �! TrimraiLT"being mounting is less than 24'and there ( 2-'.`,, ; 'm -Ili ) are no avialable roof attachment points. I I TrimraiLT"Roof TrimraiLT"Roof Attachment Required Attachment Required i RAFTER I I a________::.......... .a.Lte Floating Trim Clip TrimraiLT"Roof Attachment or Required Floating Trim Clip Acceptable LC _ IL7.4 ALL;2- - Aj U Ptj ; % G ^Wim __1 SECURING TRIMRAIL WITH FLOATING TRIM CLIPS: Floating Trim Clip TrimraiLT"Roof When necessary, use floating trim clips to secure Required Attachment Required trimrail to module. Installation should occur after module is secured. Floating Trim Clip fastens to module flange and clips inside of trimrail as shown fI – – – – RAFTER above. ; DODSFM FRAME MICROINVERTER & WIRE MGMT. DI DD MICRORAIL'M INSTALLATION GUIDE PAGE "'i +'_,bib 'OPi��_ �� • �. u. Ill-la___:-..12------- eat t Ea •4 41111fr '''e ' Coppli III _ri° I 1 3* r" tsk "1 wit • �� ilk if I Ya PRE-INSTALL MLPE: Install MLPE in a location on MLPE MOUNTING LOCATION & WIRE MANAGEMENT: Install the 7.f•i ILA 6 the module that will not interfere with microrails or MLPE Mount on the short side of the module when mounting int. ti grounding lugs.To use trunk cable most efficiently, landscape orientation. Install MLPE Mount on the long side of IVAir - install MLPE components in the same locations on module when mouting in portrait orientation. - , all modules in the same row. ABOVE IMAGE:MLPE mount w/ microinverter&wire management TORQUE VALUE:20FT-LBS (SEE NOTE ON PAGE A) \?, BELOW IMAGE:MLPE mount w/power optimizer &wire mgnt. E' di (i .. . . 00o L MICROINVERTER & WIRE MGMT. I " "" " 00 MICRORAIUM INSTALLATION GUIDE PAGE n_ _in bn n ��� � #� j/#14 n , n s a el I - - MICROINVERTER:Before installing a row of modules MICROINVERTER CONNECTION: Before securing WIRE MANAGEMENT: Verify wire management is place microinverter trunk cable. a module to the Microrails, install trunk cable complete after each row is installed. mounting clip on the connector block.Attach clip to module flange.Plug microinverter into connector. EXAMPLES: el ses de* lee -aaji Ai Tit% TIPS&TRICKS:Tie a loose knot in the microinverter MICROINVERTER TRUNK CABLE: The trunk cable TIPS & TRICKS: Twisting the PV module wires Engage connector wire to help manage the length. can be managed securely by using stainless steel and /or tying a loose knot can also help manage wire management clips attached to the module these wires. frame. 000. sFm FRAME FINISHING TOUCHES III 0 MICRDRAILTM INSTALLATION GUIDE PAGE ,,,.(1 .,..,„ TRIMRAIL BONDING: Attach a bonding clip from the TrimrailTM to an adjacent module.Fully seat bonding 0 4, slai i clip until radius portion is in contact with trim mating surface and module flange. 41 711411 400.4%.N.N....NN/S Bonding Clip:A N/S bonding clip must be used POST INSTALL HEIGHT ADJUSTMENT: Height adjustment of each attached MicrorailTM assembly can be to bond adjacent rows of modules together. performed by inserting a long 1/4'hex drive through the cap and into the helix.CAUTION:DO NOT RAISE THE BASE HIGHER THAN THE TOP OF THE TOWER. ORB FRAME SYSTEM BONDING & GROUNDING o .•,: • DO MICRORAILTM INSTALLATION GUIDE PAGE cA 0.1110 0.1140 -I II /i I -I H 1 O—O I E-W BONDING PATH:E-W module to module bonding I YYY I l is accomplished with 2 pre-installed bonding clips I I which engage on the secure side of the MicrorailTM and splice. I hITI 1—rl 1 i 1 rl T I I 1 f' I I r1 I •I i 1 I I I I I I f [-1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Star Washer is WEEBLUG Single Use Only r Single Use Only Kij. L7* ai,TERMINAL TORQUE, ce.! '.-ar i `130 Install Conductor and -, torque to the following: TERMINALTORQUE, TERMINALTOROUE,4-6 AWG:35in-lbs Install Conductor and Install Conductor and Prilk‘-s ��.1�- 8 AWG:25 in-lbs torque to the following: torque to the following: , \• 10-14AWG:20 in-lbs 4-14AWG:35in-lbs 6-14AWG:7ft-lbs O LUG DETAIL&TOROUE INFO LUG DETAIL&TORQUE INFO LUG DETAIL&TORQUE INFO N-S BONDING PATH: N-S system bonding is Ilsco Lay-In Lug(GBL-4DBT) Ilsco Flange Lug(SGB-4) Wiley WEEBLug(6.7) accomplished through a N-S bonding clip. Insert • 10-32 mounting hardware • 1/4"mounting hardware • 1/4"mounting hardware each end of the N-S bonding clip onto a module • Torque=5 ft-lb • Torque=75 in-lb • Torque= 10 ft-lb • AWG 4-14-Solid or Stranded • AWG 414-Solid or Stranded • AWG 6-14-Solid or Stranded frame flange. It is recommended that N-S bonding clips be installed on both edges of the array. NOTE:ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION System bonding is accomplished through modules.System grounding accomplished by attaching a ground lug to any module at a location on the module specified by the module manufacturer. 000 SUN SYSTEM ENPNASE micRomvERTER GROUNDING o MICRORAIUM INSTALLATION GUIDE PAGE SFM EQUIPMENT GROUNDING THROUGH ENPHASE MICROINVERTERS The Enphase M215 and M250 microinverters have integrated grounding capabilities built in. In this case,the DC circuit is isolated from the AC circuit,and the AC equipment grounding conductor (EGC) is built into the Enphase Engage integrated grounding(IG)cabling. In order to ground the SunFrame Microrail racking system through the Enphase Microinverter and Engage cable assembly,there must be a minimum of three PV modules connected to the same trunk cable within a continuous array. Continuous array is defined as a grouping of modules installed and electrically bonded per `�� the requirements of this installation guide. The microinverters are bonded to the v, SunFrame Microrailvia the mounting hardware. Complete equipment grounding is achieved through the Enphase Engage cabling with integrated grounding (IC). No additional EGC grounding cables are required,as all fault current is carried to ground through the Engage cable. • 4 .• Lu . .• 00o FRAME UL CODE COMPLIANCE NOTES • DO MICRORAIUM INSTALLATION GUIDE PAGE SYSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the manner specified in the SUNFRAME MICRORAIL(SFM) Installation Guide.SFM has been classified to the system level fire portion of UL 1703. This UL 1703 classification has been incorporated into the UL 2703 product certification. SFM has achieved Class A,B & C system level performance for tow slope &steep sloped roofs when used in conjunction with type 1 and type 2 modules.Class A,B &C system Level fire performance is inherent in the SFM design,and no additional mitigation measures are required.The fire classification rating is valid for any roof pitch.There is no required minimum or maximum height limitation above the roof deck to maintain the Class A,B &C fire rating for SFM.SUNFRAME MICRORAILTh components shall be mounted over a fire resistant roof covering rated for the application. Module Type Roof Slope System Level Fire Rating Microrail Direction Module Orientation Mitigation Required Type 1 and Type 2 Step Slope & Low Slope Class A,B & C East-West Landscape OR Portrait None Required UL2703 TEST MODULES See page'R'for a list of modules that were electrically and mechanically tested or qualified with the SUNFRAME MICRORAIL(SFM)components outlined within this Installation Guide. — • Maxium Area of Module=17.98sqft • UL2703 Design Load Ratings: 60. a) Downward Pressure—33 PSF b) Upward Pressure—33 PSF %'•' c) Down-Slope Load—10 PSF e� • • Tested Loads: • /' a) Downward Pressure—50 PSF/2400 Pa � b) Upward Pressure— 50 PSF/2400Pa ii c) Down-Slope Load—15 PSF/720 Pa • Maximum Span=6ft • Use with a maximum over current protection device OCPD of 30A ♦� 1 LABEL MARKINGS ♦♦ �) • System fire class rating:See installation instructions for installation requirements ♦♦ to achieve a specified system fire class rating with Unirac. ♦♦ • Unirac SUNFRAME MICRORAILTM is listed to UL 2703. ♦♦ • All splices within a system are shipped with marking indicating date and location ♦ �. of manufacture. • II7 2 DOI MD@IUM MODULE ENGAGEMENT „BE FRAME TESTED / CERTIFIED MODULE LIST R DO MICRORAIUM INSTALLATION GUIDE PAGE Module Manufacturer Module Series Part No. (Module Manufacturer Module Series I Part No. Canadian Solar C56V-M CS6V-XXXM Q-Cells B.LINE PLUS BFR G4.1 B.LINE PLUS BFR G4.1 XXX CS6P-P C56P-)00(P B.LINE PRO BFR 64.1 B.LINE PRO BFR G4.1)01,X CS6K-M CS6K-XXXM Q.PLUS-G4 QPLUS-64 XXX CSSA-M CSSA-XX%,CSSA-MM QPLUS BFR G4.1 QPLUS BFR 64.1 XXX CS6K-MS CS6K-XXX MS Q.PRO BFR G4.1 Q.PRO BFR 64.1 XXX CS6U-P CS6U-XXXP Q.PRO-G4 Q.PRO-G4 XXX CS6U-M CS6U-XXXM Q.PRO BFR 64.3 Q.PRO BFR G4.3 XXX CS6X-P C56X-XXXP - Renesola alt 60 cell modules Virtus 11 CS6P-M CS6P-XXXM 156 Series JA Solar 1AP6 1AP660-XXX/3BB Suniva MV Serres 60 MVXXXX-60 JAM6 IAM6-60-XXX/SI Optimus OPT XXX-60-4-100 Jinko 1KM XXX P-60 1KM XXX P-60 Sunpower E-Series E20-XXX-COM 1KM XXX PP30 1KM XXX PP-60 X-Serres X21-XXX 1KM XXX M-60 1KM XXX M-60 X-Series X22-X-C-AC Kyocera KU-60 KUXXX-6MCA P-Series SPR-P17-xxx-COM LGMonoX LG XXX SIC-L4 "Evaluated with both the G3 and G5 frame” NeON LG XXXN1C-G4 Trina TSM-PA05 TSM-XXXPA05 LG Q1C-A5 LG xxx 0C-AS TSM-PD05 TSM-XXX PD05 LG Q1K-A5 1G xxx Q1K-A5 TSM-DD05 TSM-100(DX5 L6 N1K-A5 LG xxx N1K-AS Yingli YGE YL)0X P-29b t6 NIC-AS 16 xxx N1C-A5 LG S1C-A5 LG xxx S1C-A5 LG AIC-A5 l6 xxx A1C-A5 LG N2T-A4 16 xxx N2T-A4 r— - LG N2T-AS L6 xxx N2T-A5 LG N2W-A5 L6 xxx N2W-A5 LGS2W-A5 L6 xxx 52W-A5 Panasonic VBHN 5A16 VEIN 3xx 5A16 VBHN SA15 VBHN xxx 5A15 f XXX denotes module wattage. • : OO® FRAME MODULE MAINTENANCE B , c,.. 00 MICRORAILTM INSTALLATION GUIDE PAGE L r Ill . ` ' t - -- _ _ ---- INW*; V 1.Loosen T splice bolts approximately 2. Remove bolts and caps from 3' 3.Slide splices away from the module 4. Lift module and disconnect MLPE 3 turns.DO NOT REMOVE. Microrails and attached splices to be removed cables r "_� j`74:40:04011:4 S. Remove Module. Reverse steps to '�' / replace module removed. " Ii Bonding note: If both sides of array 1 �I� / are bonded with he Bonding Clips, � as recommended,then no additional ��� bonding is required for module I��I ' i maintenance. �RPIf necessary, on® row of modules "err I % ��II containing the module being "� A.,4\ � f'��II removed,one additional bonding clip d. I "I : can be added to the edge of the arra / '� / VIII opposite of the edge with bonding ���I, clips already installed. 1 4,40,tat Se /�I • o°osFms,RuANME CONSIDERATIONS & MAINTENANCE 0 0E3 MICRORAILTM INSTALLATION GUIDE PAGE ELECTRICAL CONSIDERATIONS SUNFRAME Microrail is intended to be used with PV modules that have a system voltage less than or equal to that allowable by the NEC.A minimum 10AWG,105°C copper grounding conductor should be used to ground a system,according to the National Electric Code(NEC).It is the installer's responsibility to check local codes, which may vary. INTERCONNECTION INFORMATION There is no size constraint beyond structural thermal expansion limits on how many SUNFRAME Microrails & PV modules can be mechanically interconnected for any given configuration,provided that the installation meets the requirements of applicable building and fire codes. GROUNDING NOTES:The installation must be conducted in accordance with the National Electric Code (NEC) and the authority having jurisdiction.Please refer to these resources in your location for required grounding lug quantities specific to your project.The grounding/bonding components may overhang parts of the array so care must be taken when walking around the array to avoid damage.Conductor fastener torque values depend on conductor size. See product data sheets for correct torque values.This racking system may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instruction PERIODIC INSPECTION:Conduct periodic inspections for loose components,loose fasteners or any corrosion,immediately replace any affected components. • ./ • 4 ' •