HomeMy WebLinkAboutEngineered Plan - 2017r- r .;- LOCUS PLAN e 0 MAP 11 LOT 33 PROVIDE VENTED EJECTOR PUMP FOR } BATH AND KITCHEN FLOW DECOMMISSION (PUMP AND FILL) EXISTING LEACHING PIT MAP 11 LOT 34 LEGEND T.O.F. EL = 45.7 SLAB EL. 38.5 x44.4 LAWN OUTLET TEE TO BE FITTED WITH P LYLOK MODEL PL525 LTER 4" DIA, SOLID PVC PIPE (13') SLOPES 0.02 EL.=43.0 (PROPOSED) EL=42.70 F7S LANE! 92.00�' 20cv LOCUS'-,, \M T 3'2 `. ACR S± L'3AWN 1`- 11 0 RAISE AND REROUTE EXISTING PLUMBING THROUGH BASEMENT ,DECOMMISSION (PUMP AND FILL) ;EXISTING LEACHING PIT PROVIDE TEE FINISHED GRADE FIRST 2' TO BE 4" SOLID PVC SCH. 40 4" SOLID PVC SCH. 40 (15') SLOPE 0.01 (MIN.) L EL.=42.45 DISTRIBUTION EL.=41.98 EL.=42.20 BOX EL.=42.03 1,500 GALLON, 2-C8MPARTMENT ST CONCRETE SEPTIC TANK 20' MIN. TO FOUNDATION WALL x44 - - -- --49--- - -- EXISTING CONTOURS X49.5 EXISTING SPOT ELEVATIONS PROPERTY LINES TP-1 OBSERVATION HOLE LOCATION EDGE OF BITUMINOUS PAVEMENT MAP 11 LOT 31 20 43.9 SEPTIC SYSTEM PROFILE NOT TO SCALE COVER INFILTRATORS WITH FILTER FABRIC PROPOSED VENT WITH CHARCOAL FILTER AND INSECT SCREEN EVEL 4' PERF. SCH. 40 PVC OBSERVATION PORT END CAP WITH CAP SET WITHIN /_ 3" OF FINISHED GRADE 12" MIN. TITLE 5 SAND EL = 41.70 REMOVE UNSUITABLE SOIL & REPLACE WITH CLEAN FILL IN ACCORDANCE WITH 310 CMR 15.255(3) LEACHING BED CONSISTING OF 5 ROWS OF 7 DEPTH TO GROUNDWATER 34" W x 48" L x 8" H INFILTRATORS - 140 L.F. 5' MINIMUM USE INFILTRATOR QUICK4 PLUS STANDARD LP UNITS GROUNDWATER ELEV. < 31.95 BASED ON TEST PIT TP-2 WATER TIGHT SECURABLE COVERS TO GRADE WITH BRICK AND - MORTAR OR APPROVED EQUAL PROVIDE TANK ACCESS COVER OVER BAFFLE OUTLET TEE TO BE FITTED WITH GAS BAFFLE-1 595 S.F. CONVENTIONAL SYSTEM FOOTPRINT PROPOSED VENT (PRESBY GRANITE POST) -5' UNSUITABLE SOIL REMOVAL LIMIT PROPOSED 14.2' X 28.0' LEACHING BED - WITH 5 ROWS OF 7 QUICK 4 PLUS STANDARD LOW PROFILE CHAMBERS PROPOSED DISTRIBUTION BOX PROPOSED 1,500 GALLON, 2-COMPARTMENT SEPTIC TANK SITE BENCHMARK: TOP OF LOWEST FRONT STEP, EL.=45.46 (NAND 88) PORCH BED BED BATH ROOM ROOM KITCHEN ROOK ENT. BATH ROOM LIVING DI IROAOM ROOM BED ROOM FLOOR PLAN NOT TO SCALE GARAGE 4'-7" 4' 0' 40 P.V.i OUTLET TEE TO BE FITTED WITH POLYLOK MODEL PL525 FILTER WITH SUPPORT LEG PROVIDE TANK r 4"j OUTLET 5' -8" / �L SET TANK ON 6" OF CRUSHED STONE OR APPROVED LEVEL BASE CROSS SECTION 1,500 GALLON 2-COMPARI PRECAST SEPTIC TANK NOT TO SCALE It 15.5" ---a-7.5" 3 - 2"--) 5 - 5" DIA. OUTLETS loll 15" 7" "4 6" 4 .1 8 SET D-BOX ON 6" CRUS STONE LEVELING BASE NOTE: DISTRIBUTION BOX COMPLY TO MINIMUM REQL OF 310 CMR 15.232. DISTRIBUTION BO NOT TO SCALE 1 A/111AI1'1 �/Y [] ESTABLISH VEGETATIVE COVER r- FILTER FABRIC r-TITLE 5 SAND TOPSOIL 712)1-36't 8" SEE ELEVATION SCHEDULE 6" MIN. INFILTRATOR' QUICK4 PLUS STANDARD LP CONFIGURATION NOT TO SCALE I DATE DESCRIPTION N O T E S 1. THE CONTRACTOR SHALL NOTIFY THE LOCAL BOARD OF HEALTH AND COLLINS ENGINEERING GROUP AT LEAST 48 HOURS PRIOR TO REQUIRED INSPECTIONS. 2. SITE BENCHMARK IS THE TOP OF THE LOWEST FRONT STEP AS INDICATED ON THIS PLAN: EL = 45.46 (NAVD 88). 3. HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO OPERATE OVER THE LIMITS OF THE SEWAGE DISPOSAL FIELD DURING THE COURSE OF CONSTRUCTION OF THE SYSTEM. 4. NO FIELD MODIFICATIONS TO THE SEWAGE SYSTEM SHALL BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER AND THE LOCAL BOARD OF HEALTH. 5. UNLESS OTHERWISE NOTED ALL SYSTEM COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES. 6. DISTRIBUTION BOX SHALL BE MANUFACTURED BY J&R PRECAST, INC. OR APPROVED EQUAL. 7. GROUT TO BE USED AT ALL POINTS WHERE PIPES ENTER OR LEAVE ALL CONCRETE STRUCTURES IN ORDER TO PROVIDE A WATERTIGHT SEAL. 8. THE FIRST TWO FEET OF EACH LINE EXITING THE DISTRIBUTION BOX SHALL BE LEVEL. 9. THIS SYSTEM IS NOT DESIGNED TO ACCOMMODATE A GARBAGE GRINDER OR WATER FILTRATION SYSTEM BACKWASH, 10. SYSTEM COMPONENTS TO WITHSTAND H-10 LOADING CRITERIA. 11. PROPERTY LINE SHOWN IS APPROXIMATE ONLY AND IS NOT A RESULT OF A PROPERTY LINE SURVEY. 12. THE CONTRACTOR SHALL DECOMMISSION (PUMP & FILL OR REMOVE) THE EXISTING SEPTIC SYSTEM AND ALL ASSOCIATED PIPING IN ACCORDANCE WITH 310 CMR 15.354. 13. AS SHOWN, THERE ARE NO KNOWN WELLS WITHIN 100 FEET OF THE PROPOSED LEACH FIELD. 14. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED (LOAM AND SEED) TO INCLUDE HISTORIC TEST PITS OUTSIDE CONSTRUCTION LIMITS. 15. CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING ANY APPLICABLE PERMITS, 16. CONTRACTOR WILL BE RESPONSIBLE FOR CONTACTING DIG SAFE (888-DIGSAFE) AND ANY OTHER APPLICABLE UTILITY COMPANIES PRIOR TO STARTING WORK. 17. UNDERGROUND UTILITY LOCATIONS SHOWN ARE APPROXIMATE ONLY. 18. CONTRACTOR WILL BE RESPONSIBLE FOR COMBINING LAUNDRY FLOW WITH SYSTEM. 19. CONTRACTOR RESPONSIBLE FOR IMPLEMENTING ALL O.S.H.A. PROCEDURES TO INCLUDE BUT NOT LIMITED TO CONFINED SPACE ENTRY PROCEDURES. 20. CONTRACTOR RESPONSIBLE FOR CONFIRMING LOCATION OF EXISTING LEACHING FACILITY 21. CONTRACTOR TO CONFIRM EXISTING PLUMBING, BENCHMARK, AND SILL ELEVATIONS PRIOR TO CONSTRUCTION. 22. MAGNETIC LOCATOR TAPE TO BE PLACED ON ALL SEPTIC SYSTEM COMPONENTS. 23. CONTRACTOR RESPONSIBLE FOR REPAIRING ANY DAMAGE TO LAWN IRRIGATION SYSTEM. D E S I G N D A T A DESIGN FLOW: 3 BEDROOMS x 110 GPD/BEDROOM = 330 GPD SEPTIC TANK: 330 GPD x 2.0 = 660 GALLONS USE NEW 1,500 GALLON SEPTIC TANK SOIL ABSORPTION SYSTEM: PERCOLATION RATE = <2 MIN./INCH (CLASS I SOIL) DESIGN LOADING RATE = 0.74 GPD/SF LEACHING AREA REQ'D = GPD) 446 SF 0..7474 GPD SF - USE 14.2' X 28.0' LEACHING BED WITH 5 ROWS OF 7 INFILTRATORS = 140 L.F. INFILTRATOR LEACHING AREA = 4.73 S.F/L.F. LEACHING AREA PROVIDED: 140 L.F. X 4.73 S.F/L.F = 662 SF > 446 SF REQUIRED DAILY FLOW CAPACITY: 662 SF X 0.74 GPD/SF = 490 GPD > 330 GPD REQ'D y.., I.h Depart eat ' VE - --- Date S 0 I L D A T A zo/y J � = ATOE: JUNE 22, 2017 - PKI PERFORMED BY: GEORGE R. COLLINS, P.E. WITNESSED BY: PHIL RENAUD, YARMOUTH BOH SOIL SOIL SOIL SOIL HORIZ. COLOR TP-1 DEPTH ELEV. HORIZ. COLOR TP-2 DEPTH ELEV. FILL/A 0 44.52 15" Bw 10YR 5/6 SANDY LOAM Bw 10YR 5/6 58" BOTTOM 42" OF PERC HOLE C 2.5Y 5/2 MED. SAND C 2.5Y 5/2 0 44.45 16" 38" 1 1140" 32.85 1 1150" 31.95 EST. SEASONAL HIGH GROUNDWATER ELEV. < 31.95 DESIGN PERC RATE = 1 " IN <2 MIN. NOTE: LAYERS FILL/A, B, AND C TO BE REMOVED TO A DEPTH OF 48" BELOW GRADE AND REPLACED WITH CLEAN FILL IN ACCORDANCE WITH 310 CMR 15.255(3). UNSUITABLE SOIL TO BE REMOVED TO A DISTANCE OF 5'-0" BEYOND THE LIMITS OF THE SOIL ABSORPTION SYSTEM. DRAWING TITLE PLAN AND DETAILS SUBSURFACE SEWAGE DISPOSAL SYSTEM UPGRADE SCALE:. AS SHOWN rGEORGE SYARMOUTH, $ 9FQSTEA�' PROJECT 129 BLUE ROCK ROAD MA DATE: 8-1-17 DRAWNSWR CLIENT JAMES LANGEN 33' BROAD STREET, SUITE 1 100, BOSTON, MA 02109 DESIGNED BY: SWR COL INS CIVIL ENGINEERING GROUP, INC. BRAINTREE - FALMOUTH - WEST BRIDGEWATER IVIL ENGINEERING - LAND SURVEY - L.S.P. SERVICES 225 SOUTH MAIN STREET, WEST BRIDGEWATER, MA 02379 TEL: 508-580-2332 MOBILE: 617-347-1363 E-MAIL: GRCPE®AOL.COM CHECKED BY: GRC DRAWING N0. APPROVED BY: GRC PROJECT NO. 17-113-2441 BY APP. i I i