HomeMy WebLinkAboutEngineered Plan - 20180 0 U .c a 1a- 0 00 0 0 b 0 0 0 0 z 0 0 U g S. a. rn I 00 0 N L N c 0 0 a U a a� rn a t E 0 SOIL TEST PIT DATA NOT TO SCALE TEST PIT TP-1 GRD. EL. 41.7 SHGW EL 28.2 EL 33.7 EL 32.2 EL 28.2 FILL 9 BW MEDIUM SAND 1OYR 5/6 11 C COARSE SAND 2.5Y 6/6 NO GROUNDWATER OBSERVED = 1i NOT TO SCALE REMOVABLE COVER 6" 4" ONSITE SOIL i EVALUATION I DATE: JULY 12, 2018 TEST BY: BSC GROUP, INC. WITNESSED BY: AMY VON HONE LICENSED SOIL EVALUATOR: TODD MacDONALD, EIT, SE#14157 PERCOLATION RATE: < 2 MINS./INCH SOIL CLASS: CLASS 1 L.T.A.R.: 0.74 GPD/S.F. LEGEND -777-1 WAIVED UNSUITABLE MATERIALS (TO BE REMOVED) RA PERCOLATION DOG TEST RANGE 52" ADPE RISER 2" WALLS ter_ • ESTIMATED -Z- SEASONAL HIGH GROUNf WATER FLOOR SEE ATTACHED j I ,i Y� i 21" � I. �- NOTES: 1. PROVIDE INLET TEE OR BAFFLE WHERE SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR IN PUMPED SYSTEM. 2. FIRST TWO FEET OF PIPE OUT OF DIST. BOX TO BE LAID LEVEL 3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 4. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. 5. CONCRETE COVER SHALL BE RAISED TO WITHIN 6 INCHES OF FINISHED GRADE. DESIGN CALCULATIONS DESIGN FLOW 3 BEDROOMS 0 110 GPD/BEDROOM = 330 GPD 330 GPD X 200% = 660 GALLONS USE 1,500 GALLON SEPTIC TANK E DESIGN PERC. RATE: <2 MIN/INCH LONG TERM APPL RATE: 0.74 GPD/SF 330 GPD _ 0.74 GPD/SF = 446 SF SIZE OF LEACHING FACILITY PROVIDED USE (2) 500 GALLON H-10 CONCRETE LEACHING CHAMBERS IN TRENCH CONFIGURATION WITH 4' STONE ON ENDS AND 4' STONE ON SIDES. BOTTOM AREA: 25' X 12.83' = 320.7 S.F. SIDEWALL AREA: 2 X (2 X (25' + 12.83')) = 151.3 S.F. EFFECTIVE LEACHING AREA = 472 S.F. 472 S.F. X 0.74 GPD/S.F. = 349 GPD (INSTALLED CAPACITY) 349 GPD > 330 GPD (19 GPD RESERVE CAPACITY PROVIDED) 1,000 GALLON SEPTIC TANK PLAN VIEW LOT 71 i i 01. I 1 61 w ,1 i 'O o EXISTING 1,000 GALLON SEPTIC TANK TO REMAIN ,fitt' 1 EXISTING TO REMAIN PROPOSED RAISE AT LEAST ONE EXISTING COVER DIST. BOX TO WITHIN 6" OF FINISHED GRADE NOTES: THE RISER SHALL BE 18" HDPE PIPE 1. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION I CONC. COVER SHALL BE WATERTIGHT. 6" MAX. 500 GALLON CONC. 2. TEES SHALL BE SCH. 40 PVC AND SHALL BE LOCATED LEACHING CHAMBER WITHIN 12" OF TANK WALL AND ACCESSIBLE FROM TANK (Np,) COVER. PROPOSED 10" 3" : LOCATE a INLET TEE OUTLET TEE UNDER COVER W/GAS BAFFLE 3" CROSS-SECTION VIEW PLAN VIEW OBSERVATION PORT NOT TO SCALE CHING CHAMBER CH - 4" PERFORATED PVC 20" ACCESS COVER W/SCREW CAP TO EXTEND DOWN TO WITHIN 3 INCHES TO NATURAL SUBGRADE OF FINISH GRADE 5" DIA. KNOCKOUT (TYP.) LOAM AND SEED ALL DISTURBED- AREAS �1-1/2"TAPER ////1/////./' i //////, I CONC. 12-36" COVER RISER O 0 CI CI L� L� 34" 24" CI C] 0 0 0 CI I� C] C7 0 C� CI C7 EFFECTIVE 0 O CI C7 Cl DEPTH 8'-6" 4'-10" FRONT VIEW 12'-10" NOTES 23' OVERDIG SIDE VIEW 1. ONE ACCESS COVER PER SYSTEM SHALL BE RAISED TO FINISH GRADE. 2. CHAMBERS SHALL BE 500 GALLON LEACHING DRYWELL, MANUFACTURED BY SHOREY OR APPROVED EQUAL. 3. GEOTEXTILE FABRIC MAY BE USED IN LIEU OF DOUBLE WASHED STONE. LOT69 CONSTRUCTION NOTES CONTRACTOR AND OWNER TO DISCUSS RETAINING WALLS AND TREES PRIOR TO THE INSTALLATION OF SYSTEM. 5 ? A 26' r5 fcTv PROPOSED LIMITS OF 5' OVERDIG / 8oA0 EXCAVATION TO "C" E HORIZON Q AIpE) I R Q I `N (40� W LOT JOZ 111 2" LAYER OF 1/8" TO 1/2" DOUBLE WASHED STONE ABOVE CROWN OF PIPE 3/4" TO 1-1/2- DOUBLE WASHED STONE TO CROWN OF PIPE DEPT.,.BSC V, LOCUS INFORMATION CURRENT OWNER: THE ANTHONY MITRANO SR. FAMILY TRUST TITLE REFERENCE: DEED BOOK 28610, PAGE 112 PLAN REFERENCE: PLAN BOOK 207, PAGE 57 ASSESSORS MAP: 134 PARCEL: 119 ZONING DISTRICT: R-40 SETBACKS: FRONT 30' SIDE 20' REAR 20' OVERLAY DISTRICT: O.K.H. NITROGEN SENSITIVE ZONE: NOT A ZONE II FEMA FLOOD ZONE DISTRICT: ZONE X, DATED JULY 16, 2014 PANEL #25001CO579 J MINIMUM i LOT SIZE: 40,000 S.F. EXISTING LOT SIZE: 11,000t S.F. GENERAL NOTES 1. THIS PLAN- IS ONLY INTENDED FOR THE PERMITTING AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITIES. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO 310 CMR 15.000 AND YARMOUTH BOARD OF HEALTH REGULATIONS. 3. THERE ARE NO KNOWN OR PROPOSED PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY. 4. IF AN OVERDIG IS SPECIFIED, REMOVE ALL TOPSOIL, SUBSOIL AND OTHER UNSUITABLE MATERIALS. 5. IF AN OVERDIG IS SPECIFIED, REPLACE ALL EXCAVATED MATERIALS WITHIN THE LIMIT OF EXCAVATION WITH CLEAN GRANULAR SAND, FREE FROM ORGANIC MATERIAL AND DELETRIOUS SUBSTANCES. MIXTURES AND LAYERS OF DIFFERENT CLASSES OF SOIL SHALL NOT BE USED. FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 2 INCHES. A SIEVE ANALYSIS USING A #4 SIEVE SHALL BE PERFORMED ON A REPRESENTATIVE SAMPLE OF FILL UP TO 45% BY WEIGHT MAY BE RETAINED ON THE #4 SIEVE. SUCH ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SPECIFICATIONS: 100% MUST PASS #4 SIEVE 10% MUST PASS #50 SIEVE 0 220% MUST PASS #100 SIEVE 0-15% MUST PASS #200 SIEVE 6. EXISTING UTILITIES WHERE SHOWN ON THE PLANS ARE APPROXIMATE. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT "ALL SUBSURFACE STRUCTURES ARE SHOWN. CONTRACTOR SHALL VERIFY THE SIZE, LOCATION AND ELEVATION OF INVERTS OF UTILITIES AND STRUCTURES, WITHIN THE LIMIT OF WORK, PRIOR TO THE START OF CONSTRUCTION. IF ANY DISCREPANCIES ARE DISCOVERED OR FIELD CHANGES REQUIRED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY COORDINATING THE PROPOSED CONSTRUCTION ACTIVITIES WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANIES, AND SHALL COMPLETE THE PROPOSED WORK WITHOUT ANY INTERUPTIONS IN SERVICE. 1 8. CONTRACTOR IS REQUIRED TO N01IFY DIG -SAFE, PER MASS. STATUTE CHAPTER 82. SECTION 40 (1-888-344-7233) A MINIMUM OF 72 HOURS PRIOR TO THE START OF CONSTRUCTION. 9. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. INSTALLATION Percaiit valid1"'for tdF:PA1R O1 SEPTIC 3YSTF:R1`` OR USE OF A GARBAGE GRINDER AT THIS PROPERTY IS NOT ALLOWED PER 310 CMR ONO Y, due to State' and Local septic variances. 13oard of IHealth review and approval is required lire' 15.240(4). awry .;future addrtionsLreilnsations/altcratiuns to sewage Gauirtio and/or structures/ilrsellirag• 10. THE WATERLINE SHALL BE SLEEVED OR RELOCATED PRIOR TO CONSTRUCTION OF THE :irillouth fic a.1th Ovpar anent. RESERVE AREA IF NEEDED). ( APPROVED.. - '`.Date VARIANCES REQUESTED I / i Y LINER -� tK t q I BENCHMARK MAG NAIL SE ELEV 43.79 W''' vv TITLE 5: 310 CMR: 15,211 (1) 1.) TO ALLOW THE LEACHING AREA TO BE 5' FROM THE STREET LINE IN LIEU OF 10'. A 5' VARIANCE IS REQUESTED, 2.) TO ALLOW THE LEACHING AREA TO BE 7' FROM THE WATER LINE IN LIEU OF 10'. A 3' VARIANCE IS REQUESTED. SYSTEM PROFILE NOT TO SCALE 4" SCH. 40 PVC L= 9t FT. EL.= 43.00 S=0.04 TOP FOUNDATION FIRST PIPE LENGTH DISTRIBUTION NOTE: SEPTIC TANK BOX MAGNETIC REFLECTIVE TAPE SHALL BE PROVIDED IN THE TRENCH OVER ALL PVC PIPING TO BE SET LEVEL FINISH GRADE FOR MIN. 2' 40.8-41.8 �-- 4" SCH. 40 PVC 5' OVERDIG TOP EL=38.83 40MIL 000000c000 POLY oor�000000CM UNEf� 0 00000t�0000 TOP39.0 _ BOT. EL=36.00 \_ BOT. 35.0 LEACHING 7.8' SEPARATION CHAMBERS EL=28.2 l 1 ESTIMATED S.H.G.W. (BOTTOM OF TEST PIT) 6A MARGARET JOSEPH Rl D LOCUS � �. � N � I �Z = v m � � Z o � v LOCUS MAP NOT TO SCALE OF M4Ss9 yGs c o gR1AN G. � YERGATIAN W � CIVIL Igo. 46206�Q BRIAN G. YERGATIA DATE PROFESSIONAL ENGINEER SEPTIC SYSTEM DESIGN /UPGRADE # 72 BARNACLE ROAD IN YARMOUTH PORT MASSACHUSETTS - (BARNSTABLE COUNTY) SITE PLAN . DULY 20, 2018 � UTItEgEOMCD JUL 2 5 2018 HLaLiH