Loading...
HomeMy WebLinkAboutEngineered Plan - 2018N MIDIRON KEY: DRIV EXISTING CONTOUR: - - - - r PROPOSED CONTOUR: ------------- ti 1z EXISTING SPOT ELEVATION: 25.54 25.5 U PROPOSED SPOT ELEVATION: 8 TEST HOLE: * am UTILITY POLE: -0- 1 C) FENCE LINE: O GG HYDRANT: -. RETAINING WALL: o LOCATION MAP LOT 235 (24,618 SF) ASSESSORS MAP: 90 PARCEL:120.1 LAND COURT CASE 28477L W g< Svc oc z 8-38 25.0' 60 N LEACH AREA DETAIL 104 - 105 \ Z 103 \ 2-12" oaks 102 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 2 - 500 GALLON CHAMBERS (8.5' x 4.8' x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (25' x 12.8' x 2' DEEP) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) = 112 GAL/DAY BOTTOM AREA: 25' x 12.8' = 320 SF (0.74) = 237 GAUDAY CAPACITY = 349 GAL/DAY SEPTIC SYSTEM SECTION RST FLOOR COVERS WITHIN 6" 104.78 OF FINISHED GRADE ` TOP OF v, FOUNDATION`'\ •�`'-• =aL„ „^\\ti ,\ -�,, \ _,V\\ „ \\\ FINISHED GRAB TEE IN T MAX. 102.3/ D-BOX ELEV, ff (1 M N) a 1 ELEV. - 00.8 97,93 9 Y6 ELEV. ELEV. D-BOX ELEV. 1500 GAL MECHANICALLY COMPACTED) SEPTIC TANK 6" OF STONE UNDER OR ECHANICALLY COMPACTED) ELEV. TEE SIZES: GAS BAFFLE INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN AT OUTLET TEE N gJ�O� two, Pertmit' valid for I2h:PAtld Oh' SEI'TI(' SYS fh;l �O ONLY: due to State and I ucal septic variances. Board of Ileatth review and approval is required for any future additions/renu. rtiorixi,rllerations to GOdIs GF, y I P' sewage facilities and/or structures/d��eltinK. �F N 108 yiirmoufh Health 1)cpartnrent ,v J 105 106 107 o. 'I � ®`. L �S / V! N 107 N \ - 19� Date 106 ap 101 104 63 100 - 24" maple na -.._ 103 1 102 I _ th-1 I G E 98 t, _ 18"oak , � ,; �, 4 100 "e' ,. J W ' \ �p'� 99/ P` `- 98 t5 `� 6 97 - s � 97 or�Q a, 96 APPROXIMATE LOCATION OF UNDERGROUND ELECTRIC. CONTRACTOR TO MARKOUT PRIOR TO CONSTRUCTION. �VX'OFMgSS9c TERRWARNER F, Y No. 8211 -�- k -7I�o/i6 REQUIRED VARIANCES FROM TITLE FIVE: 1. SECTION 15.211: LEACH AREA TO BE LESS THAN 10' FROM LOT LINE (VARIANCE OF T). z LEACH AREA LOCATION DETAIL DECK �- --�--- sh SUN ROOM BED 7bhROOM . I BATH KITCHEN DEN/ BEDROOM BATH �_ BED LIVING DINING ROOM ROOM i ROOM EXISTING FLOOR PLAN TEST HOLE LOGS ENGINEER: THOMAS MCLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 6-27-18 PERCOLATION RATE: < 2 MIN/IN PEASTONE OR FILTER FABRIC 3/4" - 1 1/2" DOUBLE WASHED STONE /-INSPECTION PORT ELEV= 98.33 [all:. : :: : I.1 95.5 4 4 ELEV 25' x 12.8' 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (25' x 12.8' x 2' DEEP) TH-1 99.0 O/A HORIZON ELEV. LOAMY SAND 10YR 3/3 98.2 B HORIZON LOAMY SAND 10YR 6/8 96.5 C HORIZON MEDIUM SAND 2.5Y 7/4 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D-BOX TO BE SET LEVEL. 5 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3' WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING CESS POOLS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D-BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. RECEN ED JUL 25 2018 SITE P LOCATION: 10 AUGUSTA WAY, S. YARMOUTH, MA PREPARED FOR: JOHN LUMSDEN DATE: 6-29-18 SCALE: 1" = 20' 3 y F p GARAGE BASS RIVER ENGINEERING THOMAS J. McLELLAN, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048