Loading...
HomeMy WebLinkAboutEngineered Plans - 2018LOCUS DATA CURRENT OWNER STEFAN VOGEL SHIRLEY VOGEL PLAN REFERENCE 348-20 DEED REFERENCE 26108-330 ZONING DISTRICT R-40 FLOOD ZONE "X" ASSESSORS MAP 108 PARCEL 45-05131 OVERLAY DISTRICT ZONE II LOT AREA 22,500f S.F. SITE & SEWAGE REPAIR PLAN #26 DEB'S HILL ROAD IN YARMOUTH PORT, MA DATE: JULY 9, 2018 OWNER/APPLICANT: STEFAN VOGEL 26 DEBS HILL ROAD UNIT 513 YARMOUTH PORT, 02675 SHEET 1 OF 2 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS. SU RVEY@YAH 00. COM NI o z z G IMESTERN RD o DEBS HILL RD. LOCUS 6 LOCUS MAP NOT TO SCALE: 18-0110 �1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 C7 1 11 1 � 1 .S 1 11 � 1 1 0 11 11 1 11 11 1 I, rJ 0 \G - IW D 1 oz 1 g 1 1 1 1 ; o.00 I EDWARD A STONE No.289$C #28 UNIT 5A 2 BEDROOMS �� z- At, 2, - e. Varmouth Health Department APPRQVED E 180.00, N fig•4S28„ LIVING ROM FAMILY ROOM KIT. #26 --'�'— UNIT 5B :N� BATH BED BED #1 BATH\ \ EXISTING SEPTIC TO REMAIN-\ Date 02 LOT 4 LOT 5 22,500t ;r -10 U EXISTING 1,000 GALLON SEPTIC 'TANK TO REMAIN o ------------ i 26.3' 100.7 99.6 Xr 1 1 BENCHMARK: CORNER OF CONCRETE BULKHEAD. EL.=102.16 0 0 X 100.4 12.0' NOTE: REMOVE BUSHES & ROOTS FOR 2' AROUND TANK EXISTING LEACHING PIT TO BE PUMPED, CRUSHED, SAND FILLED AND ABANDONED IN ACCORDANCE WITH TITLE 5. wx�-1 00.8 � i oit 00 m EXISTING TREE TO BE REMOVED X 100.2 �� �41\\ °o PROPOSED LOT 6 11.3'x16' LEACHING AREA PROPOSED 0 20 30 40 OBSERVATION PORT I GRAPHIC SCALE: 1 INCH = 20 FEET RAISE COVERS TO WITHIN 6" OF FINISH GRADE; T.C.F. 102.16 FINISH GRADE �\ ELEV. 100.8 FINISH GRADE ELEV. 100.4 ELEV. 100.3 r2.To 3' OF COVER EXISTING INV.=4 mIrv-o mnn 99.33 10"TEE 14"TEE INSTALL GAS BAFFLE 4'-1" LIQUID. LEVEL VERTICAL DATUM: ASSUMED BENCH MARK USED: CORNER OF BULKHEAD ELEVATION 102.16 18-0110 SITE & SEWAGE REPAIR PLAN /Fz DEB'S HILL ROAD IN YARMOUTH PORT, MA DATE: JULY 9, 2018 OWNER/APPLICANT: STEFAN VOGEL 26 DEBS HILL ROAD UNIT 513 YARMOUTH PORT, 02675 SHEET 2 OF 2 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS.SURVEY@YAHOO.COM EXISTING 1,000 GALLON SEPTIC TANK TO REMAIN 10' OS= 0.14 4" PVC SCH 40 n 5' OS= 0.01 INV.= 99.16 SYSTEM DESIGN OBSERVATION EXISTING DESIGN FLOW PORT TO GRADE 2 BEDROOMS AT110 GPB/D Z0 GPD GROUND ELEVATION 100.2 REQUIRED SEPTIC TANK 2.4' OF COVER 220 x-? _ _ _____298 GAL. 3 EXISTING SEPTIC TANK = __1 QQQ GAL. S.ET "7.5QUIK-4" STANDARD PLUS LEVEL INV=90 >o p -- 16.0' - I °m8\1mL 96.83 M O USE (16) QUIK 4 STANDARD PLUS CHAMBERS TOTALING 64 LINEAR FEET ELEV, 89.50 48"x34"02" STONELESS BED FORMATION NO GROUNDWATER TPIT#1 ( FOUR ROWS OF FOUR PANELS ) CONSTRUCTION NOTES: /_3 OUTLET H-10 DB3 INV.= 97.72 97.55 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. VEHICULAR TRAFFIC, PARKING OF VEHICLES AND PLACING MATERIALS OVER THE SEPTIC TANK, DISTRIBUTION BOX AND S.A.S. AREA IS PROHIBITED GENERAL NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 3" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS OTHERWISE SPECIFIED. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. 13. MAGNETIC TAPE ON ALL COMPONENTS. 2 OBSERVATION PORT / SCREW CAP TO GRADE irl �-2.83'-+- 2.83'--- - 2.83'--�- 2.83'-� 11.32' END VIEW SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC RATE -� ----MIN./INCH LONG_ TERM APPL. RATE-0•74-GPD/S.F. SIZE OF LEACHING SYSTEM PROVIDED: 220 _ 0.74 SF/GPD = -2-9-4.-S.F. MIN. REQ. USING 16 STONELESS UNITS INFILTRATOR - 16 QUIK "4" STANDARD PLUS 4.73 SF / LF X (4' x16)= 302S.F 302 x 0.74 G/SF = 223 GPD 223 GPD PROV > 220 GPD REQ. = 3 GPD RES. NO (GARBAGE DISPOSAL / GRINDER ALLOWED) DTH #1 16 INDICATES DEEP TEST HOLE INDICATES P-1 42" PERC TEST NO MOTTLING NO WEEPING 126" INDICATES ADJ. GROUNDWATER NO OBS. GROUNDWATER NO OBSERVED GROUNDWATER DEPTH TO BOTTOM OF HOLE 10.5' VARIANCES REQUESTED NONE D.T.H. #1 ib DATE: 6 /21 /18 GROUND ELEV. 100.0 NO GROUNDWATER A 1OYR 4/2 LOAMY SAND 16" B 10Y 6/6 LOAMY SAND EL. = 98.0 24" 42" C 2.5Y 6/6 MED. SAND SOME BOULDE NO G.WATER 1126" EL. = 89.5 B.O.H. PHIL RENAULD SOIL EVALUATOR ED. STONE BACKHOE OPERATOR. ELLIS (KEVIN) BROTHERS SOIL TYPE: 1 PERC RATE: 3 MIN. PER INCH LOADING RATE: 0_74 GAL/SF/MIN