HomeMy WebLinkAboutEngineered Plan - Rev. 2018100. 36 LOCUS MAP GENERAL NO TES : I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SI TE PLAN. J. ALL CONSTRUCTION METHODS AND MA TER I AL S AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EOUAL . 6. SEPTIC TANK AND PUMP CHAMBER TO BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. 7. BEFORE CONSTRUCTION CALL `DIG -SAFE-. 1-888-DIG-SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE DESIGN ENGINEER TWO DAYS PRIOR TO CONSTRUCTION OF THE SYSTEM TO ALLOW FOR SCHEDULING OF THE CONSTRUCTION INSPECTIONS. 9. EXISTING SEPTIC TANK AND LEACHING TO BE PUMPED DRY AND BACKFILLED. ./0. ALL UNSUITABLE MATERIAL (FILL. A & B LAYERS) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. I I. INVERT AT THE DWELLING TO BE RAISED TO THE ELEVATION SHOWN. 1'- PERF PIPE MIN. 2' OF ACCESS COVERS MUST BE WI THIN ACCESS COVER MUST WIGRIFICE DIFFUSERS PEA 5TONE BE TO FINISH GRADE? 6' OF FINISH GRADE 7\ v 1-1 EFFLUENT 1 FILTE I I 97.95 1500 GALLON I NF I L TRA TOR I M-1530 POLYPROPYLENE SEPTIC TANK 6- CRUSHED STONE COMPACTED BASE PUMP 97, 4 2 - MANI FOLD 97,9 MANIFOLD AND FORCE MAIN °o TO DRAIN BACK TO PUMP 500 GALLON CHAMBER WHEN PUMP SHUTS OFF INFILTRATOR I M-540 POL YPROPYLENE PUMP CHAMBER WF WOODED SWAMP - - WF \ \ \ FDG \ F of \ �9 1 f / 50.00 3/4' - 1 1/2- DIA. DOUBLE WASHED STONE ''CL EANOUT SEE DETAIL I 'x 28- LEACH FIELD IV OBSERVED AND ADJUSTED GROUNDWATER. EL-94.2 VARIANCES REOUI RED : TITLE 5. MAXIMUM FEASIBLE COMPLIANCE SECTION 15.212:Ib) DEPTH TO GROUNDWATER 5' IS REQUIRED BETWEEN THE BOTTOM OF THE SAS AND THE MAXIMUM GROUNDWATER ELEVATION. 4' IS PROPOSED. A 1' VARIANCE 15 REQUESTED. NIN-20 CAST IRON F IRON FRAME AND COVERS TO FINISH GRADE MOTARED IN PLACE WITH CONCRETE FOOTING 2-45° OR SWEE CL EANOUT ALTERNATE F 3. 44 '-7 90° o 0 114' VENT HOLE oapo0_ I- LATERAL 1/4' DRAIN HOLE AT END OF LATERAL 2' MANIFOLD 1/4' PERFORATION IN CROWN OF PIPE W/POLYLOK ORIFICE DIFFUSOR ORIFICE DIFFUSER � LOT 242 1 10 4 '� 1 6.250f S.F. Il 96.4 l'ermlt valid for REPAIR. OF SEPTIC SYST1 �1 +96.4 SHED ONLY, • due 'to State. and Local septic variances. 1 Boa rld of llcalth review%and approval is reclilirrd for 96.7 / any, future' addiMons/renoy ions/alterations to II SD. P R EDGE H sewage t iuiiMes And/or structtjr s/dHclling 11 OF iYErLANO - -� Yi4mou`th lk'alth Department: ��e1 96.2 1500 GALLON�J WORK lyµtT .��� 1 SEPTIC FriNK - - 1 974- w. EXISTING ZANK \ / TP*l w lalDliC Date \ I/Mp 8.2� N _ CHAMBER : �:: / 3 _-- O y O/ +97.3 110 ..-....: PECK Oo 24" DIAM COVER TO GRADE hMINIMUM PUMP SYSTEM NO TES : I. PUMP TO BE MYERS RESIDENTIAL SEWAGE PUMP MODEL SRM4 OR EQUAL. 4" PVC INLET 2. THE PUMP SHALL START AND STOP AT THE ELEVATIONS SHOWN. 3. THE PUMP SHALL BE INSTALLED /N STRfCT CONFORMANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND TITLE V REGULATIONS. PUMP DISCHARGE SHALL BE 2 INCHES. PUMP SHOULD BE ABLE TO BE DISCONNECTED AND LIFTED OUT OF THE PUMP CHAMBER WITHOUT HAVING TO ENTER THE PUMP CHAMBER. 4. THE ALARM SHALL START AT THE ELEVATION SHOWN AND BE POWERED BY A CIRCUIT SEPARATE FROM THE PUMP POWER, 5. AN ELECTRICAL PERMIT MUST BE OBTAINED FOR THIS INSTALLATION. 6. USE GATE VALVE TO ADJUST DISTAL HEAD AT END OF NETWORK TO 2.$'. o a 0 i /Op FROA E 9 .4 BATH - � OF �TLAND BEDROOM _� . o Pm BEDROOM 99.7 99.2 INSPECTION f0 .... PORTITYP) ' o/ a- EE +99. 8 -/ 100 - - - LEACH FIELD - % FENCE S PUMP DE TA I :NOT TO SCALE USING 500 GAL. PUMP CHAMBER BM. CB/OH FND EL-100.64 Pvc OUTLET FLOAT SWITCHES K 1 TrJIEN Gb / _---- 41V1NG ROOM 1 1 99.7 1 � 10' + 100.6 l ... CO �/ WATER LINE TO S%t'; .•;.•.: _ / BE RELOCATED \ f 10' FROM SAS \ PICKET SO/L REMOVAL-1 UP l0 SEE NOTE 10. \ \ 100.3 yJ 1� 100.0 AD N O CUI T R 0 CIR m CB CONCRETE BOUND -W WATER L I NE 9 HYDRANT -G GAS LINE OHW- OVER HEAD WIRES LIGHT POST -- - UNDERGROUND ELECTRIC LINE -T- UNDERGROUND TELEPHONE LINE - CT V- UNDERGROUND CABL EV I S I ON LINE + 40.4 SPOT ELEVATION 40....... EXISTING CONTOUR 40 PROPOSED CONTOUR T00.5 0 10 20 40 cl' INVERT ELEVATIONS: INVERT AT BUILDING: 98.5 INVERT IN SEPTIC TANK: 98.25 INVERT OUT SEPTIC TANK: 98.0 INVERT IN PUMP CHAMBER: 97.95 INVERT OUT PUMP CHAMBER: 97.4 INVERT MANIFOLD: 97.9 INVERT IN LEACH FIELD: 98.7 INVERT END LEACH FIELD: 98.9 BOTTOM OF LEACH FIELD: 98.2 ADJUSTED GROUND WATER: 94.2 OBSERVED GROUND WATER: 94.2 BOTTOM OF TEST HOLE *l: 90.1 INDEX WELL MI W 29. ZONE A MARCH 2O18 READING-5.5'. ADJ-0.0' 4" DIAM INSPECTION PORT 0 DIA. o0 o° DESIGN CR I TER I A : DESIGN FLOW: 2 BEDROOMS AT 110 O.P.D. PER BEDROOM EQUALS 220 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED. 220 G.P.D. X 20OX - 440 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE ( 5 MIN/INCH SOIL TEXTURAL CLASS - / EFFLUENT LOADING RATE - 0.74 GPD/SF 220 GPD / 0.74 GPD/SF - 298 S.F. REQUIRED 3Utl St X U. /4 f7vv/W* - ztf lvFU SOIL TES T PIT DATA & INDICATES V_ fWICATES PERCOLATION _ OBSERVED TEST GROUNDWATER TP •I TP *2 HORIZON TEXTURE COLOR HORIZON TEXTURE COLOR FILL LOAMY A IOYR SAND 3/4 28" -- -- ------ - -- -- 95.1 to. --- -- ---- -- ---^ 98.9 A LOAMY IOYR B LOAMY IOYR SAND 3/4 SAND 5/6 30' --- - ---- -- - - --- 94.9 24' -- -- -- ---- - -- -- 97.7 B LOAMY IOYR C / MEDIUM IOYR SAND 516 SAND 6/4 40' ---- ----- - - -- -- 94.1 C % ME01w 149YR SAND 614 SO" 93.2 I ct ° 7 No. 38721 n 66" _ 94.2 IF 90. 1 70" 91T.9 DATE: MARCH 7. 2018 TEST BY: STEPHEN HAAS J \ W1 TNESSED BY: PHIL RENAUD PERC RATE: ( 2 MIN/INCH S E7P T l C S YS TAM DEES / ON 51 C I RCU I T ROAD NORTH, MAP 48. PARCEL 30 WES T YARMOLUTH PREPARED EOR: ,JAMES l TZO 1. B BONS 40 BENJAM I N WAY. WEST YARMOUTH . MA 02673 SCALE': l 20* MAY 1 7. 20 / 8 REVISED MAY 28. 2018 ( TANKS ) STEPHEN A. HAAS ENGINEERING P.O. Box 16 South Denn i s MA 02660 (508) 362---8 1 32 JOB NO: I8-004 f