Loading...
HomeMy WebLinkAboutBLD-18-4346 kk,.i/ t//8" .0 •YjR TOWN OF YARMOUTH Building Department BUILDING 41tO (508)398-2231 ext.1261 0 "we y PERMIT NO :BLD-18:004346 PERMIT �c�"'•., '�y ISSUE DATE ;08/21/2018 JOB WEATHER CARD Nor APPLICANT ;HALIL ASLAN PERMIT TO New IAT(LOCATION) 173 OCEAN AVE,SOUTH YARMOUTH, MA 02664 1 ZONING DISTRICT I 1 Bldg.Type: 'Residential SUBDIVISION MAP BLOCK LOT 033.286 BUILDING IS TO BE: CONST TYPE V B USE GROUP R-3 REMARKS Alteration-install roof mounted solar panels(978-601-9083) CONTRACTOR LICENSE 05-098996 Construction Supervisor HALIL ASIAN HALIL ASIAN AREA(SQ Fl) 569,242,080. EST COST($) 15616.00 PERMIT FEE($) 400.00 Dracut,MA 01826 OWNER BAUER SHERYL H BUILDING DEPT BY ADDRESS BAUER MICHAEL W,47 TROWBRIDGE AVE NEWTONVILLE, MA 02460 PHONE THIS PERMIT CONVEYS NO RIGHT TO OCCUPY ANY STREET, ALLEY OR SIDEWALK OR ANY PART THEREOF, EITHER TEMPORARILY OR PERMANENTLY. ENCROACHMENTS ON PUBLIC PROPERTY, NOT SPECIFICALLY PERMITTED UNDER THE BUILDING CODE, MUST BE APPROVED BY THE JURISDICTION. STREET OR ALLEY GRADES AS WELL AS DEPTH AND LOCATION OF PUBLIC SEWERS MAY BE OBTAINED FROM THE DEPARTMENT OF PUBLIC WORKS.THE ISSUANCE OF THIS PERMIT DOES NOT RELEASE THE APPLICANT FROM MINIMUM INSPECTIONS REQUIRED FOR ALL APPROVED PLANS MUST BE RETAINED ON WHERE APPLICABLE SEPARATE CONSTRUCTION WORK 1)FOUNDATIONS OR JOB AND THIS CARD KEPT POSTED UNTIL PERMITS ARE REQUIRED FOR FOOTINGS.2)PRIOR TO COVERING STRUCTURAL FINAL INSPECTION HAS BEEN MADE.WHERE ELECTRICAL PLUMBING/GAS MEMBERS(READY FOR LATH OR FINISH COVERING) A CERTIFICATE OF OCCUPANCY IS AND MECHANICAL 3)FINAL INSPECTION BEFORE OCCUPANCY 4) REQUIRED,SUCH BUILDING SHALL NOT BE INSTALLATIONS. REFER TO DETAILED INSPECTION SCHEDULE OCCUPIED UNTIL FINAL INSPECTION HAS BEEN MADE. POST THIS CARD SO IT IS VISIBLE FROM STREET BUILDING INSPECTIONS APPROVALS OTHER: WORK SHALL NOT PROCEED PERMIT WILL BECOME NULL AND VOID IF INPSECTIONS INDICATED ON THIS CARD UNTIL THE INSPECTOR HAS CONSTRUCTION WORK IS NOT STARTED WITHIN SIX CAN BE ARRANGED FOR BY TELEPHONE APPROVED THE VARIOUS MONTHS OF DATE THE PERMIT IS ISSUED AS NOTED OR WRITTEN NOTIFICATION. STAGES OF CONSTRUCTION AROVF TOWN:OYARMOUTH BUILDING DEPARTMENT 1146 Route 28;•South'Yarinouth, MA 02664 508-398-2231 eit.-1261 Fax 508-398-0836 FINAL AFFIDAVIT FOR SOLAR INSTALLATION I, Lic. # i Property Address Building Permit # u Electrical Permit # Date Electrical Permit Finalized Have installed the permitted solar system according to the manufactures specifications and the Mass. State Building Code. I do certify under pains and penalties of perjury that the information provided is true and correct. Permit holder sign here ($/� oOal�? c ?17M- . ' n Le / ONE & TWO FAMILY ONLY- BUILDING PERMIT Town of Yarmouth Building Department w 1146 Route 28, South Yarmouth,MA 02664-4492 ' 508-398-2231 ext. 1261 Fax 508-398-0836E IN -_rt 'gym Massachusetts State Building Code,780 CMR Building Permit Application To Construct, Repair,Renovate Or Demolish a One-or T1vo-Family Dwelling This Section For Official Use Only Building PermitNumber. l,,/77—/F DV 9.de-4ri :Date Applied: - z i/7 ��. � e-,-27-(e Building clai(Print Name) - Sigoad¢e..a_ / Date, SECTION 1:SITE INFORMATION a 4 1.1 Property Address: 1.2 Assessors fAp&Parcel Nunthgph I _ >. m -55 Oa��.. Atr, y rn n,.-1, MA 5 Notch C 1.1a Is this an accepted street?yes a< no Map Number Parcel Number r7 a�( Cr) 1.3 Zoning Information: 1.4 Property Dimensions: m • m D N Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1 ,^'y a% 1.5 Building Setbacks(ft) m m Front Yard Side Yards Rear Yard •zy r a Required Provided Required Provided Required Provi% "' 1.6 Water Supply:(M,O,L c.40,154) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone _ Outside Flood Zone/ Municipal O On site disposal system O Check if yesO SECTION 2: PROPERTY OWNERSHIP. - 2.1 Owner'of Record: �� /L/eiliar/ ) Ur TC.Irrtnown. 14 4 Ca 644 Name(Print) • City,State,ZIP , (�� ..r/ IS Ocean Av ' S�e-�6n-ator ieba niOcol'lrinle rrNy No.and Street Telephone Email Address SECTION 4:.DESCRtP1 ON Or RROPOSEI)WORK'!(check ali'that apply) . New Construction 0 Existing Building 0 Owner-Occupied O Repairs(s) 0 Alteration(s) 0 Addition O Demolition 0 Accessory Bldg.0 Number of Units_ Other ® Specify: cola/ poerotek Brief Description of Proposed Work=: /4./e,// a 4. 60 kW eke4-,eu/ Solos s\isL,.., or\ roof' of' hoteye M: s',SECTION:d(ESTIMATEDems $UCtIONCOSTs::;:v, ; ,:. i:';`!:i; _. Item Estimated Costs: r '•OIICaa1 CTa Si q' .. (Labor and Materials) ./(7£ 1.Building gCi'a: . $ /O i5"1) •-Li BuildingPetmttFe ?$ �j°1dic . feeisd .. ., :"'„Yrs illi`:' 2.Electrical $ f]Staiiflard.;City/lnwp'Applieatiori l ea,,= =, 5t46Co elTotalProjectCon!(Item 6)tiMultiplier.;; �', x--`"_ t, 3.Plumbing $ 2. Other:Fees: S.-=':'0' 771/0 }-� 4.Mechanical (HVAC) $ / " S.Mechanical (Fire ` Suppression) $ Total All Peas $' 6.Total Project Cost: $ / t ipaidjap = Check Amouiii: Cash IS (�l6 ti paidjapan- ' . 'l7 Outsta>idia Bidance -C SECTION 5:.CONSTRUCTION SERVICES . 5.1 Construction Supervisor License(CSL) 09 fl9R& I A�/r�/4 Hata A s lc vt License Number Expiration Date Name of CSL Holder List CSL Type(see below) U Vrnal -g4.- No.and Street Type Description U Unrestricted(Buildings up to 35,000 cu.ft) 4/3e04masag Virtcud; MA Pi92-CoR Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding '�"" `` SF Solid Fuel Burning Appliances r17? toot gars halt4Odur91 'Q4torIwo I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(MC) flat 7��sr�/y Het t AS IR h bqBIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name L �I ince S4- ha IIIask< I ^OCr Acro.Cori Nournnd Street _ Email address M4 01Se26 the Col 4Dk3 City/Town,Sate,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit Signed Affidavit Attached? Yes 'I( No 0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTORNAPPLIES FOR BUILDING PERMIT /r I,as Owner of the subject property,hereby authorize a4 n. a(t[,aa. to act on my behal4 in all matters relative to work authorized by this building permit application. • c/o I•-Ilei a2I frutr V3.3 J/f! Print Owner's Name(Electronic Signature) Date • • SECTION 7b:OWNERS OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this applicationic/ is true and accurate to the best of my knowledge and understanding. m'aci., ( Zhzwc- t/2 3J/C Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142k Other important information on the HIC Program can be found at www.mass.Rov/oca Information on the Construction Supervisor License can be found at www.mass.¢ov/des 2. When substantial work is planned,provide the information below: Total floor area(sq.ft) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/batbs Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" 1 Y'tiR,‘ TOWN OF YARMOUTH • 0 ` BUILDING DEPARTMENT ,;,,c':�€ a 0 ''�' 1146 Route 28,South Yarmouth,MA 02664 • eto 508-398-2231 ext. 1261 Fax 508-398-0836 BUILDING DEPARTMENT DEMOLITION DEBRIS DISPOSAL AFFIDAVIT Pursuant to M.G.L. Chapter 40, Section 54 and 780 CMR, Chapter 1, Section 111.5, I hereby certify that the debris resulting from the proposed work/demolition to be conducted at '13 Oce,,,„ Aye, 9arMr,cth f44 Work Address Is to be disposed of at the following location: (confraci}rrr wilt be -Fak i l debris back wi-Fh him) Said disposal site shall be a licensed solid waste facility as defined by M.G.L. Chapter 111, Section 150A. Signature of Application Date Permit No. :74 ` +=)P,Pran/iw+•r/ffe r/C ffenswArrrs'/1. r» �,q=wc,��.ne Office of Consumer Affairs&Business Regulation t�• .t. - HOME IMPROVEMENT CONTRACTOR �`..x TYPE:Individual • 'Vitt sf „ Recistratfon E x'Y'• s :169749.,, 07!2812019 HAUL ASLAN ',;,, ;ri .. 1/2 HAUL ASIAN rN�- 7 V;NAL ST. * DRACUT,MA 01826 .Y ' Undersecretan • • r . Commonwealth of Massachusetts Vi Division of Professional Licensure Board of Building Regulations and Standards Constructtori%ispervisor �3. CS-098996 .5" """"'< E'ft fres• 12/1512019 HALIL ASLAN-: " r 7 VIRAL STREET DRACUT MA 01826 St"• � gt)1t\,f IL';t . Commissioner M ;, • Grid-Tied Photovoltaic System Nuwat Energy,LLC , .a.ww mi,aa DC Rating: 4.62 kW Sheet List ..• ino""• Michael Bauer Sheet No, Sheet Title Nates PV-000 COVER NOTES 73 Ocean Ave PV-A01 SITE PLAN South Yarmouth,MA 02664 PPV-o3 DETaLS LAYOUT PV-E01 ELECTRICAL DIAGRAM PV-E02 SYSTEM CALCS&LABELS Jurisdiction: Town of South Yarmouth PV-E03 UTILITY METER Scope of Work General Notes: HOUSE VIEW NuWatt Energy shall instal a Grid-bed Photovoltaic CPV')System using LG Neon-2 1. System follows any/at Fire Code Setbacks per Ordinances of the It r y ,. 330W Mono Modules with SalarEdge Opbmzera.The Mottles shag be tush Town of South Yamnoutu ,at.. 1,4 mounted on the asphalt/comp.shingle roof and interconnected via load side breaker 2.Al projects Mi comply with the Ordinances of the Town of South -:-..**„:":1, / M-p connecbon. Yamwum. T t 3. Consbucton Hours:Tam8pm Monday-Friday,9amApm Saturday ,iizilfr'`ra •;,p,4 .q �, Notune on Sunday s legal Holidays e aW-- tJ -4.-t-n 1-.4 Equipment Specifications: 4.Product Data Sheets shag be included. -I, lk la:: '. Mottles:(14)LG330N1C-A5 5.Rooftop penetrations Mal be completed and sealed per code by a asp - - , - Optimizers:(14)SdaEdge P370 licensed contractor. ,-• tot Inverter.(1)SdarEdge SE3000tW S(240V) 8.Al Photovoltaic modules shall be tested and listed by a recognised a A , at -1. Raclung Undtac Sdar.load laboratory. `. A •"' Attachment Flashing Eco-Fasten Green-Fasten with CP-SO-Slotted Bracket and 7.Cerlficabaw shat Include UL1703,IEC61648,IEC81730. a lt4. t ..7....,-,:. k. B. A continuous ground anal be provided for the Any and for at N Aluminum Flashing Photovoltaic Equipment n n.( ---i,. Roof Mount System Specifications: 9-DC Wong shat be run Si metal conduit or raceways within enclosed St,' k Y4 - YS P spaces nabuires -...vAy.. a UniRac System asattached engineered Structural Report 10.Conduit to Wire systems and Raceways anal be located as dose as ,.y i. Yper n9 apo 11. on tot belw hips,and Arrays dlla. 11.Conduit between Sub Arrays and to DC ComblneNDtacennDeH ty •'fry • that use guidelines that normae the total amount of conduit by taking the stalest path. 12.Space Requirements for electrical equipment shat comply with NEC MAP VIEW Adds 110. Site Specifications: 1a Equipment grounding shall be sized in accordance with Table - 250.122 Occupancy,Design Wind Speed 8 Exposure.Ground 14.Connectors that are not readily accessible e and that are used in the t SnowLo Snow Loan As per stmoturel PE letter olrouds operating ala over 30V AC or DC Mal requires tool for opening and are required to be makes-Do not disconnect under load' fn...., or Not for current"eta opting-per 890.33(e)& S 15.Al)signer ml be placed SiIn Decadence with lobolding code. 18.Signs or Diredmes that be attached to the eteMcd equipment or C All Work to be in Compliance with: located adjacent to the identified equipment - / a 17.Signs shalt be of sufficient durability to withstand the environment I A 2017 National Elea Ical Code(NEC) 18.My plaques shall be metal or plastic with engraved or machete a - - o :,owe. a .s MA butane code MO CMR RmdaiY Code 9th Ed printed letters. a electro-pletn9, in a red becground with white T a w`"-`vw a 2009 International Building Code(IBC)with Miedmend lemming.ttedng.a minimum of 3/8'hand and all capital kittens - CONSTRUCTION ISSUE 20121nlemabonal Fire Code(IFC) ear ..Mchaw Sauer 2012Undorm Mechanical Code(UMC) 2909 International Residential Code(IRC)with Massachusetts Amendments nares• ASCE/ANSI 7-05 Minimum Design Loads for Cuttings and Other Structures South.owes,`.Dna aware. As amended and adopted by Town el South Yarmouth. NUWatt Energy •.ed•C«+ sae les . ..w.oisI • v S5 73 Ocean Ave South Yarmouth.MA 02664 COVER PAGE WM Sas01/0E/2018NNN [Katt prNT! 01/0E/2018M is OF MWi le Rae. r 201801-08/1 PV-000 A • • µmatt Fre9Y•LLC Nnief'mina, 1111�1i����MYw�Fmn PLAN VIEW • - NOTES • v -- • tt8 Y,ry s y, e. '#'..._' A M 1' 4 1. esta'� . @. s� t,...,,i.,,, , iY _ �- �u : . Sok r4 A m •{ tye + s El IIM b 0 -- `Y • . . 0 aa f Cl Y}, • • ,+'. -- CONSTRUCTION ISSUE YO aY 5" E .1. . 4� Atm.Ca sante Nal WW1 Energy 1 s 73 Ocean Ave a SMO Yarmouth.MA 02661 W SITE PLAN man r a «rs aau or Mel MI 1/6 201801-08/I PV-A01 A • • PVARRAAY1-MECX MCALtOADS PVaRROV2-MEOUMCZL LOADS Amoy Men 11.18 W1 Tota Flntosdtale Dead Load 3.33 psi AmiPro 18110 sat Total Phnom/tan ileadLoad 3.33 pant Amy Weft 158.73 lbs lag Dud Load per Anchor Il lei Ann Weight: 396.0 lbs Arg.Deed Leal lmrh ie Il In M1Crar le and,ran A Des ignValues by Rod Zoe Comer Edge interior Design tlDonCornergnvues by Rad De Corner Edge Interior NOTES Met Urines Rall Spew 35113 OC 36In OC 3Rn OC mat uneaten'Span 381n0C Min.O.0 36lnOC MFF.Winning Cantilever I31n OC tannin 1]nOC Ms.unelected C/eleun 131n OC 131n.01. 12InOC putted anchor Span. lan.00 1aaOC ten DC MustedMder Span IunOC ins 0C inn.0C Pennon*PPMLDS in Sibs 188 5I 1155155 Dement ores MM Load lee Abs UNShr Ise53bs weft sant Lord -n.Abi -Ysobs -saves uplift Pon Wad. -119bs 19 Sibs -alibi Mmmun MdteErerglh Albs Nnlmun ardor tannish Ares avenge Safety Factor 1015 Average Sleety Fe/Aar teas -, PANEL LAYOUT ®_ Id R I i � I I • r I -L__ I \ I ,._-.___- iI- II III i 1 I i iiI t— .® *s , -- ------ ------- ---- -- -------- -- i Ute._ G - DO UMRAC SOLARMOUNT MOWING NOTES: CONSTRUCTION ISSUE Ir 0.M1cho81 BMA! v Told Ouslbly daadensb•164 nn-.mw.. Rod Zama ens defined by dimension,a=3 Oft 10A1.Do0a.wow. n tosh e tld Menm Allowable Cantilever for RcF eal b lad theMamun Rag Spann I �paitWON Energy and Atledms[URRec SdsMwdmN Eco-Fasten Gree-FesLnwN CPSQSbdedBratlld end Nlmwn Restingetleded wO1-616Y}13'ler Bolt HaF1Mad.18 b66 I �30a,C�1.0•210:1a OMsnSshownshowna elmodiedgudng h barmen 1 Speong en Modnep gee sed Minnaw n g tee Clan,arp Method I TReds Extend Extend 3 Beyond bsupport module edges In ceder to pprt thew End Clamps. ; Pre Reps,sane Mand e�nvon gap brewery M d ng greeter Men 4O n length r May Installed,rsrdtg to the UruRs Soler Mose Code-Compliant Installation Manual ver227.3.Pub 1106161x,Me2011 73 Ocean Ave Aeedrnw,Lombard II damn re epplmMa Final aduffirnrd d enactment Rabat may be necessary dependog m field caWibors.AI attachment's are staggered amongst the harm°membra j South 02b -- -- - - - ------ ----- - MECHANICAL LAYOUT OF NIS AA year MS NOP sea •201801-08/l PV-A02 A A Nu Walt Energy.LLC Ground WEEBB _1.af..an:.mnirw.sm Module Clamp J��•rr���� em nun 00. Unirac Sdannount APOOMINNINIMI,, rA„ � KV) Rai wL-foot .. Meow Green Fasten Flashing: NOTES 2.4 \e � ECO-GFLBLK-812 Wlh pc+� 1e�oyTa\W Module(TYP. fe. ECO-CP-SO Compression Bracket �PA„.fit �O G.las pe Rip 518'x3.SS.S.Iag Bolt 'L'” ft a{GCwI Sealed w Approved Penetration - Sealant (es ve' O Attachment Profile 0 AttachmentDetail - Sale:N.TS. Scale:N.TS. it Max 12-Max Rooffroming ,PVModde Rai Overhang RaiiSplice ` RailOverhang Roof Or Attachment it ii Anchors located on alternate roof ` :: :r :: framing members iM; in 11 Staggersplice locations r Min of 2 supports within the each row of manias one either side of splice L Ty Sae Mount Rail with a max spacing of 48" • ^Mdwr Spaang^ © Staggered Attachment Detail(Typ.) © RailSpliceDetail Sale:N.T.S. Srale:N.T.S. B WEEBLug SSWasher U-MM ModuleFrame &Nut U-mm We Ground e ® SSBolt UnnacRai oI=BMIIIIMIBMIO10 SSBolt ® "maCONSTRUCTION ISSUE Nib "IIIIP1�\.•7 v ^"wclwtl BOONN. �'llllll�\� n Ocean Arlo UUrania ,I ��r »,.,.o,,,.,..we,... .2.410.12. NOMat SSFlat Nuwon Energy // SSBdt ..e � � Washerm pre UniracRai • r 73 Ocean Ave © Grounding Clip & Module O Grounding Lug & Rail South °MECHANICALMA DETAILS v MECHANICAL DETAILS Sole:N.T.S Sale:N.T.S MU a me Ca- Ma au el An of M 201801-08/1 PV-A03 A • • NuWatt Energy.LLC WIRE SCHEDULE •4 a m0.0.c...aa, Tag QTY Mara Wire 1 . Ground 9u8 Conduit Length aramaimeserm i ,soma„ TYpe ...�wm. A 2 12 Engage cable 6AWG8ARECu Freeair N/A B 6 10 THHNTHWN-2 8AWGTHWN-2 34-EMT 50ft NOTES C 3 10 THHNTHWN-2 BAWGTHWN.2 34-EMT 10ft NOTES: D ' 1.All conduit to use water-bght expansion fittings. 2.NI Rooftop conduit to be a minimum of V above the roof surface. 3.PV Connection into Load Center shall be positioned at the opposite end from WIRE SIZING the Utlily Input feeder location.(Where applicable) Tag Sire Sot Derated Ampaclty(Allowable Amps 7SC 4.All equipment to be rated NEMA-3R unless otherwise noted. Temp Berate a FIll Dente) Ampacit 5.Lowest expected ambient temperature based on ASHRAE min.mean extreme A 12 3M x 0.76.22.80A 25A dry bulb temperature for ASHRAE location most simlar to installation. 8.Highest continuous ambient temperature based on ASHRAE highest month 2% 8 10 40A It 0.76x 08 a 24.32A _35A dry bulb temperature for ASHRAE location most simiar to installation. C 10 40A x 0.96 x 1.3&40A __ 35A 7.All conductor to be copper unless noted otherwise. D I 8.Conductor sizing shall limit Voltage drop to 2%DC E.1.5%AC. SYSTEM LAMUNG SPECIFICATIONS Max.Vdc(-21t): 45.98V DC Max.Current: 13.06A Operating Vdc: 33.70V DCOperating Current: 9.80A Nominal Vac: 240V Max.ACCurrent: 15.63 A MAIN SERVICE PANEL INTERCONNECTION 120tu 1e-705,12(D)(2) Utility Feed+Solar Back Feed 2000+I 20A I.220A Buss Rating x 120 100A xI 120 I*2213A it O I 6s 11111111M=11111111M= M=sa°....etN L_ _ MqWA4 o— c arab YM p LLl _ O�. txo/z+wawdnum_ LianaC�0© 1.0330mc-.6 T 370 . o Hyl � Cp„w, se w'Pend CONSTRUCTION ISSUE 2404 2404-2M 2401-21gsMOOCH-US U+0M 2-Pole °YMICh011f was Pole urr,.r04 a ammN4 0 I no-mem. .,.e. 44CawI I s NaWott Ffiergy aww Mia ,w0�o1 '� M 4 —73 Ocean Ave South Yamouth,MA 02664 v ELECTRICAL 512 Rooftop Electr¢al I Exterior Electrical I Interior Electrical Iall " r '..' aLS gpYgas Df AAa MIS a 201801-08/1 rPV-E01 A , - :I: Qc .. NuWatl Energy,LLC ' ‘,4:. :x Y ~ war. 9. y�y Asti..wwnwo0 �t ; F !. _ P'+I rrtai5r ". 5 a+i. --- 1410 ...wr.�a rn� i d �'S NO1F3 i � Tr'R-tee ,yy x. jSi a t r ITN '#!T"'3 S'w c . 4..4' a ' ;, x u k t w ,s i ..:........at it,"4,- 0........ mai „sem !, kaik ar '414;A-1/4 ut.b - `. M e-c 8t # • ` .,.Lis 7 "1iSE ` `s+4+' k ' __>�; iett .+ imago :I m tyi ' • CONSTRUCTION ISSUE �, € s �, t t R shy .weuu F £'� h+ ''.4::',,#: [:1'.1,7;:i NUWatl Energy m.aegram "^ t b � t ,e • �,' i - •_ - ♦ �)90cean Ave krr i CIF AA eqe, MUTT METER ea egna r L6 'Ste` +k _ 1F ' 201801-08/1 PV-E03 A - • The Commonwealth of Massachusetts • �_= Department of Industrial Accidents P re•i n__,t,'�l_; . le Office of Investigations i 600 Washington Street ' 'J ,! v p Boston,MA 02111 it•tilo www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(Business/Organization/Individual): H Q i t A5104 _ Address: "7 Vint,' a City/State/Zip: Ore c u f, MA 0I4(2 fo Phone#: q1 S(,(01- q o X3 Are you an employer?Check the appropriate box: Type of project(required): 1.❑ I am a employer with 4. 0 1 am a general contractor and I employees(full and/or part-time)! have hired the sub-contractors 6. ❑New construction 2.E1 I am a sole proprietor or partner- listed on the attached sheet. 7. 0 Remodeling ship and have no employees These sub-contractors have 8. 0 Demolition workingfor me in anycapacity. employees and have workers' p ty instuance.t 9• 0 Building addition [No workers' comp.comp.insurance required] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself.[No workers'comp. right of exemption per MGL 12.0 Roof repairs insurance required.]t c. 152,§1(4),and we have no 13.f Other A��r f f1 G�2i employees. [No workers' comp.insurance required] ' 1 'Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. • :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have • employees. if the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees Below is the policy and job site information. Insurance Company Name: • Policy#or Self-ins.Lic.it: Expiration Date:/ Job Site Address: —73 Deezfrt_ e6t 4w City/State/Zip: rmntili-A N?A cay&y Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement maybe forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify unde th pats and penalties of perjury that the information provided above is true and correct Signature: A Date: 40/e Phone It: a1 fe— bat-gf2.g-2., Official use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: M. Javid Malek, P.E. Consulting Engineer 5 Strawberry lane,Wobum,MA 01801 Phone:(781)608-1780 Email:m.javidmalek@comcast.net 1/2/2018 To:Code Enforcement Division Re: Engineer Statement for Solar Roof Mount Installation at: 3 Ocean Avenue Yarmouth.MA 02664 I have verified the adequacy and structural integrity of the existing roofs on which solar power systems will he deployed(one layer shingles): 1.)2"x 8"(4) 16"c-c rafters,having appmx.horizontal span 11',pitch 18 degrees 2.)2"x 8" @ 16"c-c rafters,having appmx,horizontal span 6',pitch 12 degrees For mounting of solar panels and their installation will satisfy the sin framing design-loading requirements Massachusetts building code 780 CMR Resid ntia ode 8th Ed with, A(local) Amendments. For the installation of the solar mounting,the Unirac Solarmount rails will be anchored to the rafters with 1-foot supports with Eco-Fasten Green-Fasten flashing located at 48" sp.max.on the center of the rafters and will be securely fastened to the rafters at with 5/16"x 3"SS lag bolts.The mounting system has been designed for wind speed criteria of 110 mph Exp.II&ground snow criteria 45 psf.All attachments arc staggered amongst framing members. The Photovoltaic system and the mounting assemblies sill comply with the applicable sections of the Residential Code and loading requirements of roof-mounted collectors. Thereby,I endorse the solar panel installation and certify this design to be structurally adequate. tIf Sincerely, tAOFIRf� 4 JAVID MAUI i M.'avid Malek,P.E. ss 0ttal, F, Professional Engineer _2— j Commonwealth of Massachusetts CC:NuWatt Energy DocuSign Envelope ID:C0041 C62-06AB-41 DA-BOF0-023542AC6E58 NuWatt Energy,LLC PO Box 4464,Windham,NH 03087 Phone(857)600-3070 Customer Satisfaction cs@nuwattenergy.com QUOTATION & CONTRACT FOR A SOLAR ENERGY POWER SYSTEM CLIENT: Michael Bauer Site Address: Mailing Address: 73 Ocean Avenue 73 Ocean Avenue Yarmouth,MA 02664 Yarmouth,MA 02664 PROJECT DESCRIPTION AND MAJOR COMPONENTS A 4.62 kW PV System with turnkey installation at customer's site address stated above. - 14 LG330 solar panels - 1 SolarEdge inverter MOUNTING TYPE: - Roof Mount STANDARD COMPONENTS: - Racking and mounting components per Uniform Building Code. - AC and DC disconnects per National Electric Code and Utility - Wiring,conduit,and overcurrent protection per National Electric Code DocuSign Envelope ID:C0041 C62-06AB-41 DA-B0F0-023542AC6E58 MONITORING: - Production Meter • - SolarEdge online monitoring STANDARD LABOR: - Design system and secure basic building or electrical permit - Install specified system in good workman like manner - Complete and submit utility interconnection documents - Coordinate building,electrical and utility inspections ADDITIONAL WORK: - Line side tap for interconnection ALLOWANCES: The following items or specific prices as indicated are included in the contract price as allowances.The contract price shall be adjusted based upon actual amounts rather than estimated amounts herein: -None TENTATIVE EVENTS & MILESTONE PAYMENTS SCHEDULE: EVENT(%) APPROXIMATE AMOUNT DATE Initial Deposit 12/15/2017 $1,000.00 Before Ordering of Materials(60%of balance) 1/3/2018 $8,770.00 Upon Delivery of Materials to the Jobsite(30%of balance) 1/10/2018 $4,385.00 Upon Commissioning(Municipal Building/Electrical 1/20/2018 $1,461.00 Inspection)(Remaining balance) Total Price $15,616.00 - If there is a change in the overall quantity of panels in the span of or less than 5 panels,the price per Watt is to remain the same.If the change in quantity of panels is greater than 5, the price per Watt is subject to revision at the discretion of both parties. DocuSign Envelope ID:C0041062-06AB-41 DA-B0F0-023542AC6E58 ENTIRE AGREEMENT The parties represent that there are no oral agreements affecting this Agreement and that this Agreement contains the entire,full and integrated Agreement of the parties and that this Agreement supersedes and cancels any and all previous negotiations,arrangements,letters of intent,proposals,brochures,agreements,representations,promises,warranties and understandings between the parties as stated by,including but not limited to,any of parties' agent(s)and/or employee(s). No alteration,amendment,change or addition to this Agreement shall be binding upon either party unless reduced to writing and signed by each party. ADDITIONAL CONTRACT PROVISIONS: - All milestone payments are due Net 10 days.1.5%interest per month carrying charge. - Client shall ensure payment in the form of a personal check,bank check,certified bank check or bank wire transfer is produced at each delivery to the jobsite(modules and inverters). Neither delivery will be offloaded until NuWatt has received the proper payment. If the deliveries cannot be offloaded because proper payment is not received,Client shall be responsible for all additional costs incurred by NuWatt,including but not limited to,storage costs,additional transportation costs, interest,additional labor,penalties,etc. Client shall pay all additional costs to NuWatt prior to any subsequent deliveries. - The milestone payments and commissioning payment(payment due upon final electrical and municipal inspections)are due within five(5)business days of verbal notification by NuWatt that the work is complete. - Payments not made in accordance with the preceding terms,at the option of NuWatt,shall constitute a default and breach of this Agreement. Client agrees that upon any declared default and/or breach, among other remedies:(1)NuWatt shall be entitled to halt work and/or disconnect the system,(2) NuWatt shall be entitled to assess interest on all past due amounts at the rate of two percent(2.0%) per month(24%per year),and(3)Client shall pay NuWatt for all of NuWatt's collection fees and costs,Including but not limited to administrative costs and reasonable attorney's fees and court costs. Client is to cooperate fully in completing necessary documentation to expedite the financing institutions release of funds. - Client agrees to allow NuWatt and all delivery vehicles access to the Property over any existing driveways. In the event,adjoining land must be crossed to enable delivery,Client agrees to obtain written permission from the applicable adjoining landowners. - Neither NuWatt nor the manufacturer shall be responsible for any delay cause by action of a governmental entity,strike,riot,or other civil disturbances,shortage of materials,war,disaster,or other natural or unforeseeable calamity. - Except when caused by the negligence of NuWatt,its agents,servants,or employees,Client shall indemnify and hold harmless NuWatt from all liability,loss or other damage claims for obligations resulting from any injuries or losses,including reasonable attorneys'fees and court costs incurred by NuWatt in defending any such claims. Client shall further indemnify NuWatt for any damage to the property,premises,person,personal property or fixtures of the property by owner or property owner's employees,agents,invitees or guests. - This Agreement shall be binding upon and inure to the benefit of the parties and respective legal representatives,successors,and assigns. DocuSIgn Envelope ID:C0041 C62-06AB-41 DA-B0F0-023542AC6E58 - Should tariffs be imposed on imported solar panels between the time that this contract is signed and the ordering of the equipment,NuWatt Energy reserves the right to pass along these additional costs to the client. Signature Page Follows DoeuSIgn envelope ID:C0041 C62-06AB-41 DA-B0F0-023542AC6E58 • CLIENT ACCEPTANCE Docuslpn.A by: Customer Acceptance Signature:ctiduta N " Date:12/14/2017 C019/81257ED03.. Michael Bauer � . Do.usIgn.d by: NuWatt Acceptance Signature:) ,'t144t 6.4f., Date:12/14/2017 sE0B898Fe81Dl6A. NuWatt Energy M. Javid Malek, P.E. Consulting Engineer 5 Strawberry Lane,Woburn,MA 01801 Phone:1781)608-1780 Email:m.Javidmalek@comcast.net 2/5/2018 To: Code Enforcement Division Re:Engineer Statement for Solar Roof Mount Installation at: 3 Ocean Avenue Yarmouth,MA 02664 I have verified the adequacy and structural integrity of the existing roofs on which solar power system% will he deployed(one layer shingles): 1.)2"x 8" Cm 16"c-c rafters,having approx.horizontal span 11',pitch 18 degrees 2.)2"x 8" @ 16"c-c rafters,having approx.horizontal span 6',pitch 12 degrees For mounting of solar panels and their installation will satisfy the structural roof framing design-loading requirements Massachusetts building code 780 CMR Residential Code 9th Ed with MA(local) Amendments. For the installation of the solar mounting.the Unirac Solarmount rails will be anchored to the rafters with I.-foot supports with Eco-Fasten Green-Fasten flashing located at 48" sp.max,on the center of the rafters and will be securely fastened to the rafters at with 5/16"x 3"SS lag bolts.The mounting system has been designed for wind speed criteria of 110 mph Exp. B &ground snow criteria 45 psi All attachments an: staggered amongst framing members. The Photovoltaic system and the mounting assemblies will comply with the applicable sections of the Residential Code and loading requirements of roof-mounted collectors. Thereby,I endorse the solar panel installation and certify this design to be structurally adequate. 3A +te S %CF Sincerely, oP!A'AE �MOHDA 4r;-C4 - , �` (�� . DAVID 0 et M.David Malek, G Professional Engineer /5/ l Commonwealth of Massachusetts CC: NuWatt Energy