HomeMy WebLinkAboutEngineered Plans - 2010f 4 Route 28 LOCUS °i Sil verleaf Lane Locus Map N. T.S. First Floor N. T.S. EXCAVATION NOTES 1) EXCAVATE ALL MATERIAL ABOVE SOIL HORIZON C (SEE DEEP OBSERVATION HOLE LOG) AT APPROXIMATE ELEVATION 6.9 , FOR A LATERAL DISTANCE OF 5' ()YHERE POSSIBLE) IN ALL DIRECTIONS BEYOND THE OUTER PERIMETER OF THE LEACHING AREA. 2) FILL MATERIAL SHALL CONSIST OF CLEAN GRANULAR SAND, FREE FROM ORGANIC MATTER AND OTHER DELETERIOUS SUBSTANCES, WHICH MEETS THE TEXTURAL CRITERIA PUT FORTH IN SECTION 15.255(3) OF TITLE .5. 3) SCARIFY THE BOTTOM SURFACE OF THE EXCAVATION PRIOR TO PLACEMENT OF FILL INTO THE RETAINING STRUCTURE. 4) PLACE FILL ONLY WHEN BOTTOM SURFACE IS DRY. Map 23 Parcel 324 Proposed SAS 9 C-4 Panels No Foundation within 20' of SAS See Excavation Notes — Map 23 Parcel 323 p 0 S 6°19'58" W 36.13' Map 23 Parcel 322 No Foundation / within 20' of SAS TBM 10 hh (9 CB/D 10.4 X .E = Second Floor N. T.S. Floor Plans Note: Property lines and wall to be staked in the field prior to construction of proposed wall by a R.PDS. No Founda lion within 20' of SAS Proposed DE-5 --- Prop Wa11 Permit valid for REPAIR OF SEPTIC SYSTEM ONLY, due to State and Local septic variances. Board of Ilealth review and approval is required for any future additions/renovations/alterations to sewage facilities and/or structures/dwelling. Yarmouth Health Department APPROVED Date Map 23 Parcel 321 Prop 1,000 P—Chamber Exist 1, 000 Gal S—Tank (To remain) STANDARD NOTES 1) THIS PLAN IS FOR THE REPAIR OF A SEPTIC SYSTEM. 2) ALL INSTALLATION PROCEDURES AND MATERIALS SHALL CONFORM TO 310 CAR 15.000, THE STATE ENVIRONMENTAL CODE, TITLE 5, AND THE TOWN OF _Yc31"I220ZItI2 SUBSURFACE DISPOSAL REGULATIONS. 3) NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE OF AVAILABLE PROPERTY INFORMATION WITH RECORDED DEEDS OR ZONING REGULATIONS. 4) THIS PROPERTY IS SERVICED BY TOWN WATER 5) THERE ARE NO KNOWN WELLS WITHIN 100' OF THE PROPOSED SOIL ABSORPTION SYSTEM 6) ALL COVERS OF SYSTEM COMPONENTS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE 7) ALL SYSTEM COMPONENTS SHALL REMAIN ACCESSIBLE FOR INSPECTION. NO STRUCTURES SHALL BE LOCATED DIRECTLY UPON OR ABOVE THE COMPONENT ACCESS LOCATIONS, WHICH WOULD INTERFERE WITH THE PERFORMANCE, ACCESS, INSPECTION PUMPING OR REPAIR 8) NO DRIVEWAY, PARKING OR TURNING AREA, OR OTHER IMPERVIOUS AREA SHALL BE LOCATED ABOVE A SOIL ABSORPTION SYSTEM, EXCEPT WHEN VENTING HAS BEEN PROVIDED. 9) SEPTIC TANAS, GREASE TRAPS DOSING CHAMBERS AND DISTRIBUTION BOXES SHALL BE PLACED ON A 6" STONE BASE TO ENSURE STABILITY AND PREVENT SETTLING. 10) OUTLET DISTRIBUTION LINES SHALL REMAIN LEVEL FOR A MINIMUM OF THE FIRST TWO FEET OF THEIR LENGTH. 11) ALL SYSTEM COMPONENTS SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10' OF DRIVEWAYS OR PARKING OR TURNING AREAS, IN WHICH CASE H-20 COMPONENTS SHALL BE USED. 12) ALL BUILDING SEWER LINES SHALL HAVE AN INNER DIAMETER OF 4" AND SHALL BE CAST-IRON OR SCHEDULE 40 PVC. 13) THE DEPTH OF THE TOP OF ALL SYSTEM COMPONENTS SHALL NOT EXCEED 36" UNLESS VENTING HAS BEEN PROVIDED. 14) IN THE AREAS OF EXCAVATION, EXISTING GRADES SHALL BE REESTABLISHED UNLESS NOTED AS PROPOSED CONTOURS. 15) IF SOILS ARE ENCOUNTERED DURING THE EXCAVATION OF THE SOIL ABSORPTION SYSTEM, THAT DIFFER NOTABLY FROM THE DEEP OBSERVAMOM HOLE LOG, CONTACT A & M LAND SERVICES AND TOWN BOH BEFORE PROCEEDING. 16) CONTRACTOR TO VERIFY LOCATION OF ALL UNDERGROUND UTILITIES: PRIOR TO CONSTRUCTION 17) CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO A & M LAND SERVICES AND TOWN BOH FOR REVIEW AND APPROVAL 18) CONTRACTOR SHALL NOTIFY TOWN AND DESIGN ENGINEER AT LEAST 24. - 46 HOURS PRIOR TO INSPECTION(S). 19) MAGNETIC TAPE TO BE PLACED OVER ALL COMPONENTS ACCESS POINTS. 4'° Cap . � I i 10.5 N.G. 7.2 Base Block 8" Peastone Base Aap 23 Parcel 320 N Parcel not within Zone 11 Contribution Owner of Record Michael B and Anne E Rocco Deed Reference Bk. 24145 Pg.65 rzstall Min 40 Mil Dolt'_ liner 6" off Wall �1p1an—Reference -.— _. _ P1Ek317Pg81 Lot 3 7.2 Ferna Map Ref. 5 8 250015 0004 C Zone C June 17, 1986 Interlocking Bloch Wall (N. T. S. ) ASSESSORS MAP 23 LOT 325 Septic VARIANCE REQUEST FROM 3.10 CAR 15.000 AND TOWN OF YARMOUTH SEWAGE DISPOSAL REGULATIONS 310 CMR 15.211: Minimum Setback Distances 1.) Soil Absorption System not 10' from Property Line" 5.5' Feet Held 4.5' Variance Requested 110, r,9gs-. nor LI1N DA J. cti� o PINTO CIVIL No.46504 ' O� FG t S T So AL 1, V" 30 Three Bedroom Upgrade Repair Plan in West Yarmouth, MA Located At 166 Szlverleaf Lane West Yarmouth, MA Applican t Susan Carleton 166 ,Sll verleaf Lane West Yarmouth, MA SCALE:- 1". = 30' DATE.- January 11, 2010 PREPARED BY.• D A & M Land Services JAN 1 a�i0 618 Main Street Unit 3 West Yarmouth, MA 02673 HEAL I'm L1 Ph. (508) 737-1777 or anmlandOcomcast. GRAPHIC SCALE 15 30 60 150 ( IN FEET ) 1 inch = 30 ft. Dwg. # 6064. dwg TOP. OF FOUNDATION EL = 11. 5 rl INVERT EL Existing To Remain EXISTING GROUND SURFACE EL _ 10._7 9.3 INVERT EL Bot 6' Crushed Stone 25' S = 0.04 Install alarm & control box inside of bldg. Quick D-Box Riser Extension to within 6" of grade propoosed 2"FM D-Box - Expander (DB 5) (2x4) (See Detail) LIQUID LEVEL r SecCa'-e Chain to wall a 21 PVC Discharge �10' + 9.1 INVERT EL 8.75 Fa PIPE INV 8.55 14' INVERT EL 'BOOT' 6.I EMERG w o� STOR WEEP HOLE 1/4' GAS BAFFLE AT OUTLET ALARM ON LEVEL ml-� CHECK VALVE PUMP ON LEVEL 5.83 2 3/4" of w13 H-10 5.37 5 1 . Li c�,�w 2 MERCURY FLOAT LEVEL CONTROLS PUMP OFF LEVEI BOT INS 44 � EDT EL !o• SunP a- 0� SEWAGE PUMP GOULDS Existing 1,000 Gal Septic Tank (To Remain) 17' S = 0.04 Storage Calc 2.7 x 250 gal/ft = 675g > 440g O. K. Pump Calc 0 50 rpm 7 53' f 3. 68' = 11. 21 < 13. 0 Total Hd 44014 Cycle = 110 < 115g cycle provide 0.46 x 250g/ft = 115g/cycle > 1101cyele DEEP OBSERVATION HOLE LOG Test Hole #1 (EL = 9.6 f ) D�in ph lev Soil Soil Soil ft) Horizon Texture Color (USDA) (Munsell) 0 - 30" 7.1 Fill 30" - 32" 6.9 A MEDIUM LOAMY 10YR3/2 SAND 32" - 84" 2.6 C1 MEDIUM 10YR5�4 SAND 84" - 92" 1.9 C2 MEDIUM 10YR612 SAND Deep Obs Hole Date: 10127109 Soil Evaluator: Linda Pinto Witnessed By: P. Renauld Perc Rate: 2 Min/Inch Soil Survey Description: CARVER Geologic Material: GLACIAL OUTWASH MORRAINE Depth to Standing Water: 64" EL = 4.3 Depth to Weeping Water: NA Depth to Mottling(Color): NA Est Seasonal High GW: Adj Up 1.8 El = 6.1 USGS Observation Well: Mil 29 Date of Last Measurement: Oct 2009 Index 8.6 Comments: Zone Adrust Up Nodel 2 WD '1/3 HP 6' STONE BASE OR CPACTED BASE 4'X8'X16' SOLID OR EQUIVALENT) OM CONCRETE BLOCK 2 REQ. Proposed 1, 000 Gal Pump Chamber Shorey Precast Wa terproofed PUMP AND ALARM NOTES 1) PUMP MUST BE INSTALLED ACCORDING TO MANUFACTUER:S. SPECIFICATIONS. 2) USE MEYER OR GOULD 113 HP PUMP, OR EQUIVALENT 3) PUMP MUST BE CAPABLE OF PASSING 2" SOLIDS 4) ALARM MUST BE WIRED ON SEPARATE CURCUIT FROM PUMP. 5) ELECTRICAL WORK TO BE INSPECTED BY WIRING INSPECTOR. 6) ALARM MUST BE LOCATED IN THE HOUSE. X 11.8 Cultec #410 Filter Cover 8-112" 1 3 4" Obs Port w/Screw Can EL It.2 i i Le vet w. s5 Level Zab INVERT EL OOO�O 24" %fin b b overlap 8Oc Overlap 6' STONE BASE � '.mob 10.35 OR COMPACTED BASE INVERT EL PROPOSED LEACHING FACILITY 4 BOTTOM EL 10.65 Nine 4,-0" x 8 -0" x 8-1/2" INVERT EL 72' effective Length �) o EL 7•2 Cultec "C4" Panels lci i 5 3 2' - 3' i ESTIMATED HIGH GROUND WATER EL (Adj Up 1.0) GROUNDWATER EL`� 3 Per Y.B.H. BOTTOM TEST HOLE EL 1.6 TH ft ,rj Plan Thew Q) N. T.S. 4" Obs Port HOrz I 48' w/screw cap to grade Tee 2" ME 5) Plugged F.M. .4 Ex ander I (2 ' 4') Mtn 24" Overlap at end Min 24" Overlap at end of panels prior to backfill of panels prior to backfill f� for Splash Guard Cross Sec Lion N. T.S. 48" Cultec 410 Filterroloth - 3" Eff. -� Cultec C= 4 Notes 1.) CULTEC #410 FILTER CLOTH MUST BE UTILIZED TO MAINTAIN CULTEC PERFORMANCE STANDARDS 2.) MINIMUM OF 24- OVERLAP BENEATH BEGINNING CULTEC C4 PANELS TO HOLD #410 FILTER CLOTH TO ACT AS SPLASH GUARD AT ENTRY INVERTS 3.) FILTER CLOTH TO BE INSTALLED SMOOTH TO RIBBED SURFACES OVER CULTEC C4 PANELS, CONSULT MANUFACTURORS REP/DEALER FOR PROPER WIDTH AND LENGTH SIZING AND OVERLAP. ONE 4 " DIA PORT TO BE UTLILIZED WITH 4: DIA PVC PIPE INSTALLED FROM BOTTOM OF SAS (FIRST 10" PERF) TO COUPLE AT TOP OF PANEL AND EXTENDED WITH SOLID PIPE TO GROUND SURFACE CAPPED WITH COUPLE AND SCREW TOP LOCATED AT CENTER OF LAST PANEL Number of Bedrooms: 3 Garbage Grinder: NO Design Flow: � j� j0 (110 Gal/BR/Day x Number of BR) Septic Tank: (Existing) 1s 000 (Minimum = Design Flow x 200%) Gal Per DEP Title 5 310 CMR15.0 Mod. Cert. for Gen Use of Cultec "C4" Panels Leaching Area: 6.7 SF/LF x 72' IF = 482.4 SF Long Term Acceptance Rate (LTAR): X 0. 74 Leaching Area Design Capacity: 357 GPD (Sidewall Area + Bottom Area) x LTAR 357 GPD Provided - 330 GPD Required = 27 GPD Reserve SAS Plan View N. T.S. 5' 12" Thick Wall M Wall Plan View N.TS. ASSESSORS MAP 23 LOT 325 Three .Bedroom Sep tic Upgrade Repair Pla n _. in y �(HliHss;:. Parcel not within Zone II Contrib.= OF West Yarmouth > MA WARD A. Loca ted At Owner of Record 166 Sil verleaf Lane Michael B and Anne E. Rocco TE �J� West Yarmouth, MA Deed Referenced L LA " Bk 24145 Pg. 65 , A n �:� Applicant Susan Carleton Plan Reference •�\V g� +�'t PI Bk 317 Pg 81 '' T,. ` ''4 166 Sil verlea f Lane Lot 3 , scl�';� West Yarmouth, MA Fema Map Ref.' �° » �c� SCALE. 1 = 30 DATE.• January 11, 2010 250015 0004 CN:L�'� Zone C . June 17, 1986 cn PREPARED BY A & M Lard Serrrices 618 Main Street Unit 3 West Yarmouth, MA 02673 Ph. (508) 737-1777 or anmland®comcast.net Dwg. # 6064. dwg