Loading...
HomeMy WebLinkAboutEngineered Plan - 2018SYSTEM PROFILE NOTES 12.2' PRECAST H-10 PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE FT-0-971 MINIMUM .75' OF COVER OVER PRECAST (NOT TO SCALE) R2'0 404' 10.1' 4' OSCH40PVC 6" MIN. SUMP PIPESLEVEL 1 ST 2' 12" MIN. INTDIM.*9.3 :10" 1500 GAL H-10 14TEE SEPTIC TANK TEEN8.79' 0000000, 000o WATERTEST D'BOX GAS BAFFLE :.: °Ooo,0o000,00 FOR LEVELNESS r: 4' LIQ. LEVEL (ACME OR EQUAL) '': 8.77' 8.60' JOO O O O O O O O O O O O O O O O O O O O O�"t • 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �0000000�000�0�0�00000000000�0�0�000�0�00000. 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) MARK CORNERS OF LEACHING FIELD W/ REBAR SET 4" BELOW GRADE FILTER FABRIC 10.0 TOP 8.94' PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE 2% SLOPE \ FINISHED GRADE- \4" LOAM & SEED OR PAVE AS REQ. ' CLEAN FILL 4" PERFORATED PVC 3' O.C. S=0.005 0 3/4"-1-1/2" DOUBLE;WASHED 0 8" STONE LEACHING FIELD'. 0 8.57' LEVEL BOTTOM 0 ( 2'0% SLOPE) ( 2 % SLOPE) (1 % SLOPE) FOUNDATION- 15' SEPTIC TANK 1' D' BOX 5' - *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEN D 99 - EXISTING CONTOUR X 99 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH 1 TEST HOLE 2� SLOPE OF GROUND UTILITY POLE . _ FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: AMY VON HONE, RS DATE: 7/11/2018 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 p°' 10.3' A /LS 1OYR 3/2 18" / / / / / /S 1OYR 6/8 36" / / / / / PERC C FS 1OYR 7/4 7.3' UNSUITABLE SOIL G-W ADJ. DATA: WELL: M I W 29 ZONE: B ADJ: 0.6' MAY 2018 3.9' LEACHING FACILITY 5' REMOVAL OF UN A OUND PERIMETER D,WN TO SUITABLE WITH CLEAN MED. � SPECIFICATIONS OF 30.0' F •• 4.0' ADJUSTED GROUNDWATER 3.9' ABLE SOIL REQUIRED LEACHING FACILITY, L LAYER. REPLACE I, TO MEET CMR 15.255(3) 6"DEPTH 8.40' 1, DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST " UNITS TO BE AASHO H-10 Locus ° a 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE 90. WITH N 310 CMR 15.000 (TITLE 5.) MIN BELOW INV. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. o h 8. PIPE FOR SEPTIC SYSTEM TO; SCH. 40-4" PVC. Lewis 9. COMPONENTS NOT TO BE BACKFILLED OR Pond CONCEALED WITHOUT INSPECTION BY BOARD OF `� Nantucket HEALTH AND PERMISSION OBTAINED FROM BOARD Sound OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCUS MAP CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1 "=2000'f WORK. ASSESSORS MAP 32 PARCEL 182 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE LOCUS IS WITHIN FEMA FLOOD ZONE AE (EL. PROPOSED LEACHING FACILITY. 11) AS SHOWN ON COMMUNITY PANEL 12. EXISTING LEACHING FACILITY SHALL BE PUMPED #25001 CO588J DATED 7/16/2014 AND REMOVED OR PUMPED AND; FILLED WITH CLEAN SAND. i i KITCHEN DINING BED ROOM �Q BATH ROOM ROOM VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 16.9') REDUCTION IN SEPARATION TO GROUNDWATER FROM 5' TO 4' i LIVING BED BED SYSTEM DESIGN: ROOM ROOM ROOM GARBAGE DISPOSER IS NOT ALLOWED FLOOR PLAN DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD NOT TO SCALE USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 i USE A 1500 GAL. SEPTIC TANK i LEACHING: 330 GPD / (.74) = 446 SF REQUIRED 15'X30'=450SFOK 450 SF X .74 = 333 GPD OK USE A 15' X 30' PIPE AND STONE LEACHING FIELD FPeemit valid for REPAIR OF SrI19,1C SY5T14"m ,V,_d0e to -State and Local septic variances. rd:of flealth review and approval is required foe y .,future addiiin.ns/reno%Ations/aIterations to sewage facilities and/or structrsr es/il++e!ling: Yarmouth 1leafiil I)epartment APPROVED/ �� 1 iName Date 108" 1.3' GROUNDWATER ENCOUNTERED 84 EL. 3.3 Scale:1 "= 20' D CE' ®_ �y16 0 10 20 30 40 50 FEET DATE DANIEL A. OJALA No. 40980 0 Y ". q; ? F1 OF r?q 1` %G �' � DANIEL A��,� <; 0J^I o. U LIVIL N No. 4650 �) STE 'AL E sKi�` DANIEL A. OJALA, P.E., P.L.S. , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 35 ELTON ROAD WEST YARMOUTH, MA PREPARED FOR MADELYN BROWN DATE: JULY 12, 2018 off 508-362-4541 I fax 508-362-9880 downcope.com 00WO cO4r,6e e#7 lfteeriO , inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 18-216 CC SEPTIC-BROWN.DWG