Loading...
HomeMy WebLinkAboutEngineered Plans - 2018THIS PLAN IS INTENDED SOLELY FOR INSTALLATION OF THE SEPTIC SYSTEM DEPICTED ON IT. FOR ANY OTHER CHANGES TO THE PROPERTY INCLUDING PLACEMENT OF ADDITIONS, SHEDS, FENCES OR SWIMMING POOLS, OWNER SHOULD CONSULT WITH A MASSACHUSETTS REGISTERED LAND SURVEYOR. 3s DATUM ASc,�cG°ll/�` ELEVATION Q 411 57.24 SPOT ON BULKHEP2 SEPTIC COMPONENTS EXISTING 1000 GAL SEPTIC TANK a EXISTING LEACH PIT/ CESSPOOL DISTRIBUTION BOX E TEST PIT O Iwo EXISTING LEACH PIT TO BE PUMPED AND FILLED. EXISTING LEACH FIELD TO BE ABANDONED IN PLACE. IF OLD LEACH FIELD OVERLAPS NEW GALLERY, THAT PORTION SHALL BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND PER TITLE 5. CA p-rA D EDGE qDMMON O OF PAVEMENT ) OA D 100.00 ft =X/STING l 50 LOT 436 COTYPOjUR ' AREA = 12000 sf+— MINIMAL. GRADING PLAN BOOK 249 PAGE 113 PROPOSED IASSR MAP 67 PCL 81 51 1 I o� / EXISTING I 2 BEDROOM DWELL Wc; I 'rOPOF FNf\\§DnN � 9 1 c L e ��. 74 O 1 3 N \ CONCRETE PA T10 IB In 51 PINE 1 1 • I LNG LEACH FI EL D LOCATION OF LEACH FIELD IS APPROXIMATE 100.00 ft BED LIVING ROOM ROOM GARAGE BED = DINING KITCHEN ROOM Q ROOM m UNFINISHED B A SEMEN T PLAN SCALE: I in = 20 f t O 20 40 O 10 20 PRINT ON Il x 17 in PAPER FOR PROPER SCALE Yarmouth Health Department ! A, PP VED c) P ame Date OLD TOWN HOUSE ROAD n a N y CAPT SIMMONS y pOADLn v -1 j O CAPT SEARSE NOT TO y ROAD SCALE v WINS LOW GRAY ROAD YARMOUTH. MA THIS p IS A� COLOn PLAN USE COLOR PLAN ONLY FOR INSTALLATION FULL DETAIL IS BEST VIEWED IN FULL COLOR WATER LINE --a— WATER GATE 49 GAS LINE OVERHEAD WIRE B UTILITY_W POLE PROPOSED SOIL ABSORPTION SYSTEM -SEE DETAIL ON BACK TREE REMOVAL AT INSTALLERS DISCRETION. FOR SURVEYOR'S CERTIFICATION REFER TO 'CERTIFIED PLOT PLAN' DATED 12/5/1968 SIGNED AND STAMPED BY THOMAS KELLEY RLS ON FILE WITH THE YARMOUTH BUILDING DEPARTMENT. - TFcy IS SEWAGESYSTEM �Go LONAL TO SERVE EXISTING DWELLING RICHARD AND GAIL WIEBERS OWNER(S) OF RECORD 11 CAPT SIMMONS RD 155 Geo R der Rd s y YARMOUTH, MA Chathom. MA 02633 PROPERTY ADDRESS DovidcouOHotmoil.com DATE. -AUGUST 11. 2018 508 364-0894 PG. 1/2 : joa E T E — 4 3 0 5 °, SOIL EVALUATOR: DAVID D. COUGHANOWR. ASE *461 WITNESSED BY: AMY VON HONE. HEALTH DEPT. TEST PIT 1 NO GROUNDWATER ENCOUNTERED ELEVATION 47.45 - 38.95- DEPTH SOIL USDA SOIL SOIL COLOR SOIL OTHER TANK TO BE PUMPED DRY AT TIME OF INSTALLATION I AND EXAMINED FOR STRUCTURAL INTEGRITY. INSTALL NEW PVC OUTLET TEE EQUIPPED WITH A GAS BAFFLE. REPLACE WITH A NEW' I in 1500 GALLON TANK I TAPER � IF CRACKED. ROTTED OR OTHERWISE I COMPROMISED. I I NOT �T. TO 1 SCALE 10 8 ft-6 INLET INSTALL EFFLUENT FILTER OUTLET COVER (ZABEL OR EQUIVALENT) COVER IN OUTLET TEE. IN DROP A( LINE FROM t BUILDINGS'^ ri in TO i �s D—BOX 4 b M STONE B In gpp� 3 4 1 s 4 ASE IF NEW E SEPARATION BETWEEN INLET & OUTLET TEES NO LESS THAN LIQUID DEPTH CRDSS SECTIDN VIEN' s 12 in C MIN T Lo FROM = S N TANK � �TST Op ^AS 6 in STONE BASE CROSS SECTION VIEW i 7EXISTING NCUNS: 2 BEDROOMS X 110 GOD = 220 GPD220 GPD X 2 DAYS = 440 GALLONS 1000 GALLON SEPTIC T{I NK IF IN SOUND STRUCTURAL CONDITION. IF NOT, INSTALL NEW 1500 GALLON SEPTIC TANK. DISTRIBUTION BOX: INSTALL UNIT DEPICTED BELOW. SOIL ABSORBTION SYSTEM: THE LONG TERM ACCEPTANCE RATE FOR'A CLASS ONE SOIL WITH A PERCOLATION RATE BELOW 5 MINUTES PER INCH = 0.74 GALLONS PER DAY PERT'I SQUARE FOOT. THE 24 ft x 12.5 ft x 2 ft LEACHING GALLERY DEPICTED BELOW CAN LEACH: BOTTOM AREA = (24 x 12.5) = 300 sq. ft. SIDEWALL AREA = (24+24+12.5+12.5)x2 = 146 so. ft. TOTAL AREA = 446 sq. ft. FLOW CAPACITY = 0.74 x 446 = 330.04 gal/day INSTALL A 24 ft x 12.5 ft x 2 ft GALLERY] AS CONFIGURED BELOW. FLOW CAPACITY = 330.04 gal/day WHICH EXCEEDS THE 220 Sol/day REQUIRED FOR A TWO BEDROOM DESIGN. v DRYWELL 24.0 ft i UNIT co u to v " N N co co STONE 3.5 ft 8.5 ft 8.5 ft 3.5 ft 500 GALLON DRYWELL DIMENSIONS & DETAIL INSTALL ONE INSPECTION RISER TO WITHIN THREE USE INCHES IOF FINAL GRADE & INDICATE OASTBON H-10 T UNIT 33 in 102 !n CROSS SECTION VIEW INSTALL AN APPROVED GEOTEXTILE FABRIC OVER STONE i 28 3%4 in TO LEPTH- 3/4 in TO s�IVE/ ] ►/2 m GRAVEL:in T . 46 in 58 in 46 in 150 in —INSTALLER TO OBTAIN DISPOSAL WORKS PERMIT BEFORE STARTING WORK. —ALL COMPONENTS INSTALLED SHALL MEET THE MINIMUM REQUIREMENTS OF MASSACHUSETTS TITLE 5 SEPTIC CODE (310 CMR 15). —INSTALLER TO VERIFY LOCATIONS OF ALL UNDERGROUND UTILITIES BEFORE EXCAVATING FOR SYSTEM. —ECO—TECH ENVIRONMENTAL RECOMMENDS THE INSTALLATION OF LOW FLOW FIXTURES & APPLIANCES. AND PERIODIC PUMPING OF THE SEPTIC TANK. —SYSTEM IS NOT DESIGNED TO WITHSTAND VEHICULAR LOADING. DO NOT PARK OR DRIVE VEHICLES OVER SEPTIC SYSTEM. I TOP OF FOUNDATION EL = 52.74 +— EXISTING EXISTING EXISTING RAISE COVERS TO WITHIN ALL PIPE TO BE 4 in SC—H. 40 PVC 6 in OF FINAL GRADES AND TO PITCH AT 1/8 in/ft MIN' \ \I/ �1 I \I/ 50.00 1000 Oo GALLON L SEPTOC TANK REFER TO DETAIL BOX D-BOAC USE H-20 47.75 48.19 6 in 47.27 STONE BASE 32 ft 3' MAX PRECAST p-,a DRYWELL vim« 47.10 SOo L ABSDR TT ON 47.00 SYSTEM —REFER TO 5-12 ft DETAIL BOX q 45.00 NO GROUNDWATER BELOW MOTTLING OBSERVED — 38.95