Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2018LEGEND - 99 - - EXISTING CONTOUR X 99. 1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR [98.41 PROPOSED SPOT EL. TH1 TEST HOLE 27. SLOPE OF GROUND COL) UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING I LICE # 17-272 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED PROPOSED 12 BEDROOM DWELLING DESIGN FLOW: 12 BEDROOMS @ 110 GPD = 1320 GPD USE A 1320 GPD DESIGN FLOW SEPTIC TANK: 1320 GPD (2) = 2640 USE A 3000 GAL. SEPTIC TANK LEACHING: i 1320 GPD / (.74) = 1784 SF REQUIRED 50' X 36' = 1800 SF OK 1800 SF X .74 = 1332 GPD OK USE A 50' X 36' PIPE AND STONE LEACHING FIELD APPROVED NOTES SYSTEM M PROFILE 1. DATUM IS NAVD 88 PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) I MARK CORNERS OF LEACHING FIELD W PROVIDE INSPECTION PORTS TO 2. MUNICIPAL WATER IS EXISTING ACCESS COVERS TO WITHIN 6" OF FIN. GRADE REBAR SET 4" BELOW WITHIN 3" OF FINISH GRADE TOP FOUND. EL. 79't I' GRADE 3. MINIMUM PIPE PITCH TO BE 1/ ' 8' PER FOOT. 2% SLOPE -' \ 75.0' MINIMUM .75' OF COVER OVER PRECAST FILTER FABRIC \ 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS 73.5 TOP 70.5FINISHED GRADE- 4" LOAM & SEED OR PAVE AS REQ. TO BE AASHO H-2 PRECAST H-10 RISERS (TYP.) i 5. PIPE JOINTS TO BE MADE WATERTIGHT. 2'0 4" OS H40 PVC CLEAN FILL 6" MIN. SUMP PIPE LEVEL 1ST 2' '' •' `^•" '' 12" MIN. INT. DIM. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 4' PERFORATED PVC 6' O.C. S=0.005 -� 0 310 CMR 15.000 (TITLE 5.) *73.0' 10" 3000 GAL H-20 14" , 71.20' TEE SEPTIC TANK TEE 3/4"--1/2" DOUBLE WASHED 07. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO :N70.95 p o o °'o' ° WATERTEST D BOX s" STONE LEACHING FIELD MIN BELOW INV. BE USED FOR LOT LINE STAKING OR ANY OTHER GAS BAFFLE::; o°o°o°000000 , '°O°n9°°°°° FORILEVELNESS 70.15 o 90' PURPOSE. LEVEL BOTTOM 0T6"DEPTH 4' LIQ. LEVEL (ACME OR EQUAL) .': 70.47' 70 '30' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. . °o°°°°puOp°p°p°o°p°p°ppp°pppppppppp°pppppOp00000O°opo°°°p0°°p0°p°pppo� p°pp 50.0' V69° 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED .�4O' WITHOUT. INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 6" CRUSHED STONE OR MECHANICAL ' 7'9 -' COMPACTION. (15.221 [2]) 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING Locu / O 0 0 Dennis i Pond C / 0 LL)'i DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCUS MAP 61.5' BOTTOM TH-1 LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES g (2.5 % SLOPE) ( 2 % SLOPE) I (1 % SLOPE) NO GROUNDWATER FOUND PRIOR TO COMMENCEMENT OF WORK. I SCALE 1 =2000 t MA FOUNDATION- 75' SEPTIC TANK 24' LEACHING 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE DATE BOARD OF HEALTH ¢ BOX 17 FACILITY REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. ASSESSORS MAP 113 PARCEL 12.1.4 Q 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 0 *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES ANID ALL BUILDING SEWER OUTLETS AND ELEVATIONS ZONING SUMMARY PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM ZONING DISTRICT: R-40 DISTRICT 1 MIN. LOT SIZE 40,000 S.F. 5.4 SACG 5.4 0AC PROPOSED: 1 v \ U MIN. LOT FRONTAGE 150' 80.15' 80.15' ' MIN. FRONT SETBACK 30, 200.5' 190.8' _ MIN. SIDE SETBACK 20' 34.8' 34.8' \ MIN. REAR SETBACK 20' 605.2' 605.2' MAX. BUILDING COVERAGE 25% 2.0% 2.8% / MAX. BUILDING HEIGHT 35' 37.4' 48.2' AVERAGE NATURAL GRADE EXISTING STRUCTURE = 77.8' / - - V AVERAGE NATURAL GRADE PROPOSED STRUCTURE = 76.6' l E6GE 6_F- w_ TEST HOLE LOGS 6k N - - - - SITE IS LOCATED WITHIN OLD KING'S HIGHWAY HISTORIC / - - - - . CRAIG J. FERRARI, SE 13871 DISTRICT ENGINEER. � - - - - - - WITNESS: _AMY VON HONE, RS / DATE: 6-13-2018 63\ / PERC. RATE _ < 2 MIN/INCH CLASS I SOILS OWNER OF RE CORD / 65 SANDY SIDE CORP CA V---_ GA __` CATV � P 0 BOX 525 / nl a CATV ELEV. ELEV. CATV- CATV CATV CAT CATV 1 2 YARMOUTHPORT, MA 02675 5' REMOVAL OF L�NSUIT E SOIL REQUIR D I Q" 72.5 0" 73 At�OLIND PERIMVER OF1LEACHING FACILI �� A A 56 �LdO / _j WN TO SUITABLE S�IL LAYEk ,�EPLACE \ / WITH CLEAN/MED. S D, TO MEET \ I LS - LS. I I SPECIFICATIONS 0 310 CMR 15.255(3) / \ \ �( 74 10YR 3/2 10YR 3/2 / REFERENCES B B LS LS DEED BOOK 2942 PAGE 183 PLAN BOOK 588 PAGE 91 / / / T / 42 Y� 36" 10YR 5/6 69.5' 48" 10YR 5/6 69, BENCHMARK: \ 69 MAG NAIL = \ // `/0zo _J L O t-2_93 B 71.2' NAVD88 / \° / / � \` / �SF,AL / / � 1 / C C \ / /� PERC 5.4 AC_ ��RF / �P >3, 74 \ \ \ // J� / MS MS �o N 0 1 � \ \ / / TH 1 �P� '� 10YR 7 4 10YR 7 4 Yarmouth Health Ike artme v ED V I 132" 61.5' 132" 62' N me NO GROUNDWATER ENCOUNTERED Date _ PRO OSED �751 PAVER DRIVE 176] /s / S TITLE' 5 &TE PLAN [77] s I / OF �G 77 G G G '77, A #5 C GE L/ \N G / G PF�OPOSE _ 101.3' -G / G- G G G \(ARM.0'Lj'THPu"mT, MA �DITIOk j R I / PREPARED FOR `-,RE-ROUTE ,J EXISTING -� PLUMBING TO \ FRONT EXISTING I I p,RAG DWELLING W W � -- --- � I \W .I W W W r- - �� I CARRIAGE �8 &E T T I-- ----- / I 4 T E T&_ -I 78-� PORCH �8 I� DECK I I i T&E -�- T&E -- E OF ESN v��ZH OF ASg9 DANIEL cyG� o� DANIEL A. OJAIA� =` CIVIL J q Na. 40980 No. 46502 o � °�r;ss�°� oF� FC I S T--I?- U R� E'k° g 3 SS10NA, = 2� DATE DANIEL A. OJALA, P.E., P.L.S. l • 14 DATE: JUNE 19, 2018 REV.: JULY 2, 2018 (MOVE SAS) REV.: JULY 25, 2018 (ZONING TABLE) Scale: 1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 fax 508-362-9880 downcope.com do n cane M ineefin f, inc. civil engineers Ion d surveyors 939 Main Street ( R to 6A) YARMOUTHPORT MA 02675 17-272 EB NORRIS.dwg