HomeMy WebLinkAboutEngineered Plan - Rev. 2018KEY: - LOCUS EXISTING CONTOUR: - - - - PROPOSED CONTOUR: ----- -------- EXISTING SPOT ELEVATION: 25.5 Gv CIF N��' PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: UTILITY POLE: -0- FENCE LINE: HYDRANT: -b- a6'G. RETAINING WALL: LOO2TI(1657 S T03,4F) ASSESSORS MAP: 91 PARCEL: 51 LAND COURT CASE 28477G rye PoS�&�a\�Fe Shed 94.5 33.5' co N LEACH AREA DETAIL SEPTIC SYSTEM DESIGN CFLOW ESTIMATE: (3 EXISTING BEDROOMS, 1 PROPOSED) 4 BEDROOMS AT 110 GAL / DAY = 440 GAL / DAY SEPTIC TANK: 440 GAL / DAY x 2 DAYS = 880 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 3 - 500 GALLON CHAMBERS (8.5' x 4.8' x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (33.5' x 12.8' x 2' DEEP) SIDE AREA: (33.5' + 12.8') x 2 x 2 = 185 SF (0.74) = 137 GAUDAY BOTTOM AREA: 33.5' x 12.8' = 429 SF (0.74) = 317 GAUDAY CAPACITY = 454 GAL/DAY SEPTIC SYSTEM SECTION COVERS WITHIN 6" D2.77 OF FINISHED GRADE 3P OF 3UNDATION 1/4"per ft (under slab) ELEV. �1, ^ 1500 GAL SEPTIC TANK (6" OF STONE UNDER OR MECHANICALLY COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN DECK y15p' N6310 98 SUN � BED ROOM \ ROOM DINING , ROOM 96 12" treeBED \ \� �) ROOM BATH KITCHEN LIVING ROOM PPNO BATH Porch 1st FLOOR BED I ROOM CLOS s, BASEMENT FLOOR PLAN TO BE cA 0 walk -out MODIFIED TO SHOW A 4th BEDROOM z f .-.....1._ ..._ -= BENCHMARK AT CORNER OF 96 CONCRETE PATIO ELEVATION = 95.12 24" oak 0 �'?O� O OHO OGO �Om 94.5 95.'r •+Yd o� - \ ... ' 95.0 �5000 Oa �rd cP RAISED 1` \ GARDEN i i LP) g0 " 56 N 0 ROOM GARAGE LIVING BATH UTILITES (no full window) BASEMENT EXISTING FLOOR PLAN Yarmouth Health Dep2rrtinent eP? VED Name Date T MAX. COVER (1' MIN) ELEV. D-BOX ELEV, 6" OF STONE UNDER OR MECHANICALLY COMPACTED) ELEV. -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 8-2-18 PERCOLATION RATE: < 2 MIN/IN 2" PEASTONE OR FILTER FABRIC - 3/4" - 1 1/2" DOUBLE ­ WASHED STONE INSPECTION PORT ELEV.= 91.93 89.1 4 4 ELEV. 33.5' x 12.8' 3 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (33.5' x 12.8' x 2' DEEP) TH-1 95.0 O/A HORIZON ELEV. LOAMY SAND 10YR 3/1 94.1 B HORIZON LOAMY SAND 10YR 5/6 93.0 C HORIZON MEDIUM SAND 2.5Y 7/4 FERC AT 48" 132" 1 1 84.0 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 _4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D-BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING CESS POOLS AND LEACH PIT ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D-BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. J SITE PLAN LOCATION: 85 CURVE HILL RD., S. YARMOUTH, MA PREPARED FOR: THOMAS MAFFEI DATE: 8-2-18 ,REVISED: 8-6-18 (4 BEDROOM DESIGN) SCALE: 1" = 20'J BASS RIVER ENGINEERING i P E P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048 M 18-42