Loading...
HomeMy WebLinkAboutEngineered Plans - 2018N87'21'30"E 146.05 LOT 12 AREA = 17,352 S.F. in' 00 to N P3 BED BATH I KIT RM BATH DIN 0 rn N - � O °T LD i_Iv PIrznn FLOOR PLAN N87'21'30"E 97 95 98 96 99 I I I I I DRIV�WAY I 0 O z I 0 C� �o LLJ z � o 000 o � � EXISTI G 1'000G / I / SEP jj�1C TANK I L6 N r- r�w J oII � to 6e reused I � C� ~ `' / z m G CL j X -- LLJ �t4 20' W _ 93u\ 94, \ VEI 131.58 i -1 NEW tM bo N 0 to N oafd LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE 19 TEST PIT SCALE: 1 "=20' t valid for REPAIR OF SEPTIC SVS"1'F.M dire to State and Local septic variances. of Ileatth review and ap1moval is required for future additions/rent)%atioiisialterations to e facilities and/or structures/ilsselling, Yarmouth -:Health I)epartment APPROVED i me Date SURVEY REFERENCE: CERTIFIED PLOT PLAN BY: ED KELLEY, PLS DATED 3-20-80 WEST YARMOUTH co WHITTLER PL. � a 0 L BUCK ISLAND ROAD LOCUS MAP LOCUS INFORMATION PLAN REF: 34728D TITLE REF: D1093661 PARCEL ID: MAP 066 PAR. 076 FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 39 FROST AVENUE WEST YARMOUTH, MA PREPARED FOR ALLEN TOSCH ES AUGUST 27, 2018 MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5®gmail.com SHEET 1 OF 2 894 y, ELEV. TOP FOUNDATION NOTE: PLACE MAGNETIC MARKING TAPE OVER ALL COVERS (Existing) BRING ALL COVERS TO WITHIN 3" OF FINISH GRADE FINISHED GRADE (93.0-94.0) = 100.0 --F.G.EL- 98.2 c n r, . n� a r n r, . na cn I NOTES: EXISTSING 1,000 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL, OR EQUAL 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK WITH 1500 GALLON SEPTIC TANK IF FAILED, DAMAGED OR UNDERSIZED. 4) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: - 310 CMR 15.405 (1) (B): 1) A 1.60 FT. VARIANCE FROM 310CMR15.221(7) TO ALLOW LEACHING TO BE 4.60 Fr (MAX) BELOW GRADE VS REWD 3 FT. (H2O/VENT PROVIDED) 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND FILLED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING. 15. ALL PIPING TO BE 4" SCH 40 O 1/8"/FT (UNLESS SPECIFIED) SEPTIC SYSTEM PROFIL� SEPARATION BOTTOM OF TESTHOLE EL: 81.40 SOIL LOGS DATE: JULY 26,. 2018 SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614 WITNESS: AMY VONHONE, YARMOUTH HEALTH DEPT. Elev. TP-1 Depth 93.40 0" FILL 91.07 28" A LOAMY SAND 90.07 1OYR 4/1 40" B L 10�SISAND 88.40 60" PERC TEST C IM MSID O EL. 86.72 2.5Y 6/4 82.90 126" C2 MEDIUM SAND 2.5Y 6/6 81.40 144" PERC RATE <2 MIN/IN. ("C1" HORIZON) NO GROUNDWATER OBSERVED • 1, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Eval. Exam in October, 1999. 3/4" - 1-1/2" DOUBLE WASHED BREAKOUT ELEV.= 89.40 SOIL ABSORPTION SYSTEM (SECTION) (500 GALLON H2O LEACH CHAMBER) DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 3 BR = DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 550 gpd x 2009 = 1,100 gpd USE EXIST. 1,000G SEPTIC TANK LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F. USE TWO (2) 500 GALLON H2O PRECAST LEACH CHAMBERS W/ 4' STONE ON ENDS & 3.75' STONE ON SIDES: 25' L x 12.5' W x 2'D BOTTOM AREA: 25 x 12.5 = 312.5 SF SIDE AREA: (25 + 12.5) X 2 X 2 = 150 SF TOTAL SQUARE FEET PROVIDED = 462 vs. 445.94 REQ'D DESIGN FLOW PROVIDED: 0.74(462 S.F.) = 342.25 G.P.D. vs. 330 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 39 FROST AVENUE, WEST YARMOUTH, MA Prepared for: Tosches R ady Rooter Exc. Design and Site Plan by: SCALE DRAWN DATE MEYER & SONS, INC. N.T.S. DMM 08/27/18 PO BOX 981 EASTSANDIMCH,MA02537 REV DATE CHECKED SHEET NO. 508-3d2-29M DMM 2 of 2