HomeMy WebLinkAboutEngineered Plan - 2003�rr�ar�rr�r� �.r�+rr•wwir�r��,�rir�rr���ua ., - _ SYSTEM PROFTLE T TOP FNDN. AT EL. 24.27 EST HOLE LOGS (NOT TO SCALE) PROVIDE INSPECTION PORT WITHIN ACCESS COVER AT FIN. GRADE ACCESS COVER. (WATERTIGHT) TO 6" of FINISH GRADE ENGINEER: AH OJALA PE EL.2S.4' 1 WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM , MINIMUM 1' OF COVER 23.3 WITNESS: __ AtAy 1/o►.1 F-+-o►.le )? OVER POLY TANK MINIMUM .75 OF COVER - E •? 21.7'f * * EL. 2 .4 .. OVER PRECAST 2" DOBLE WASHED PEASTONE _ 11 /12/03 RUN PIPE LEVEL DATE: (EXIST) 16.1"(1.34') -FOR -FIRST 2' 3' MAX. PERC: RATE _ < 2 MIN/INCH EL 21.31' PROPOSED 1,500 EL 21,06' rr- GALLON POLYETHYLENE , 20.83 CLASS I SOILS P# SEPTIC TANK GAS (H-10) BAFFLE �c�oc� 20. 25' El 0 C7 CO 0 0 Cl EJ 20.42 0 20.0' CI C7 Cl I� C� C7 Cl El CI MIN (_Z-% SLOPE 6" CRUSHED STONE .OR MECHANICAL gam, 0 0 � 0 0 � C �+ 0. "" ELEV. COMPACTION. (15.221 [2]) ftS 2 0 0 171171 0 0 0 C'..] 0 oa 18.0' 0" 23.2' DEPTH OF FLOW = i A 4 (4 q SLOPE) MIN % SLOPE) 3/4" TO 1 1 /2,, DOUBLE WASHED STONE TEE SIZES: INLET DEPTH = 10„ SL OUTLET DEPTH = 14" „ 1OYR 4/1 i LEACHING B FOUNDATION- 16' SEPTIC TANK 16D' ` BOX 10' FACiLIIY ASSESSORS MAP 58 PARCEL 10$ 6.8' "THE INSTALLER SHALL VERIFY THE LS LOCATIONS OF. ALL UTILITIES AND ALL 10YR 5/6 BUILDING SEWER OUTLETS AND ELEVATIONS VARIANCE REQUESTED UNDER MAX. FEASIBLE COMPLIANCE PRIOR TO INSTALLING ANY PORTION OF 32" 20.5' 15.405: SEPTIC SYSTEM 1a: REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 5) & SEPTIC TANK TO LOT LINE (10' TO 7') i lb: REDUCTION IN SETBACK, SAS TO FULL FOUNDATION (20' C TO 15') 11.2' PERC LOT 4 FS 2.5Y 7/4 23.43 TEL RISER +19.67 � '..�" 2,95 c� 144" 1 11.2' '1 i 22 23 m NO WATER ENCOUNTERED - NOTES: m 3,50 i LOT 2173 +23,s3 1. DATUM IS ASSUMED 9,371 SFf 2352 SEPTIC DESIGN: (GARBAGE DISPOSER Is NOT ALLOWED ) SHED _ 220 2. MUNICIPAL WATER IS EXISTING DESIGN FLOW: 2_ BEDROOMS ( 110 GPD) GPD TWIN 12" OAKS USE A 220 GPD DESIGN FLOW * 3. MINIMUM PIPE PITCH TO BE 1/8 PER FOOT. ' 23,61 + r 4. DESIGN LOADING FOR ALL PRECAST, UNITS TO BE AASHO H- 10 -- ,„ PTI� IHivn: cw hrU �) = 440 _ _ 5. PIPE JOINTS TO BE MADE WATERTIGHT. - ------ - I O -4-20.1$ �.95 O o i ! EXISTING cP USE A 1500 GALLON SEPTIC TANK 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. 00 0m.� o DWELLING 11' PROP. 1500 GAL. , LEACHING: ENVIRONMENTAL CODE TITLE V. Z o , TF = 24.2V POLYETHYLENE SEPTIC TANK 2(22 -I- 8.83) 2 (.74) 91 7.' THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT W ,G l SIDES: TO BE USED FOR ANY OTHER PURPOSE: REMOVE ANY CONTAMINATED 22 x 8:$3 BOTTOM: (.74) = 143 8. PIPE FOR SEPTIC SYSTEM TO SCH, 40-4" PVC. 1 ' 1 CP SOILS WITHIN 5' OF NEW 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT t SLAB BRirr 23.52 FACILITY AND REPLACE WITH 317 234 a �-2 39 � -- - 23,54GARAOE TOTAL: S.F. GPD �,� PAro INSPECTION- BY BOARD OF HEALTH AND PERMISSION OBTAINED CLEAN MED. SAND. O FROM BOARD OF HEALTH. PAVED � t USE 2 500 GAL.' LEACHING CHAMBERS WITH 2' STONE G DRIVEwA _ I`4 5' 10 AT SIDES AND 2.5': AT ENDS 10. PUMP & REMOVE (OR FILL W/CLEAN SAND) EXISTING CESSPOOLS -(� .56 G $2 BEDRM. DEED RESTRICTION REQUIRED - t �1� 5 CONCRETE BOUND ELEV = 23.56 N �jF,P� Row OE BUSHES 23.20 23,09 BENCHMARK LEGEND p +23.39 TITLE 5 SI TE PL AN 1 2 100.0 PROPOSED SPOT ELEVATION OF � 90.35 +23A8 .. 12 JOH N SON LANE \ M 100xO EXISTING SPOT ELEVATION IN THE TOWN OF: -4 �20.70 USE CAUTION IN AREA 100 PROPOSED CONTOUR (WEST) YARMOUTH 23,22 OF GASLINE Eye 100 EXISTING CONTOUR HEAL?"H �Fp1', PREPARED FOR: ELINOf M. DEAN EXISTING DWELLING LOT 6 20 0 20 40 60 BOARD OF HEALTH MA SCALE: _ APPROVED DATE 1 20 DATE: NOVEMBER 15, 2003 off 508-362-041 - ,` - f fax 508 362-98$0 OF Mq ��lH Of Mqs� w down cape engineering, inc. o ARNE H.��CyG�� ARNE OJALA o H. �. LA CIVIL ENGINEERS CIVIL y of 63 y No.3 2 r, No.2634Q c LAND ; SURVEYORS u lA 03--336 939 main st. Yarmouth, ma 02675 A OJALA, P. e, P.L.S. DA E