Loading...
HomeMy WebLinkAboutEngineered Plan - 2008ACCESS COVERS MUST BE WITHIN 9- MINIMUM. MIN 2' OF PEASTONE 6 ' OF FINISH GRADE 3' MAXIMUM COVER OR FILTER FABRIC FIRST 2' TO BE LEVEL 3/4' - 1 1/2' D/A. DOUBLE WASHED STONE 4NOMAY PIfE 95.5 ° 40 MILL POLY GAS BAFFLE-1 95 75 $� 2 95.52 �° 5 93.0 VAPOR BARRIER 3 OUTLET 2-500 GAL LEACHING CHAMBERS 9a.s D-BOX W/4' STONE AROUND. 12.8'w x 25' 1 x 2'd 1500 GAL SEPTIC TANK 5" CRUSHED STONE OR COMPACTED BASE PROF I LE : NOT TO SCALE i"WEER T ELEVATIONS.: INVERT IN SEPTIC TANK: 96.0 INVERT OUT SEPTIC TANK: 95.75 INVERT IN DIST. BOX: 95.52 INVERT OUT DIST• BOX: 95.35 INVERT IN LEACH CHAMBER: 95.0 BOTTOM OF LEACH CHAMBER: 93.0 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE *l: 85.1 v` BLUESTN A ` ° \4j GP � Rri _ LOT 48 15. 047+ S.F. o� ono i TP•l - CESSPOOL �D BOX / P! FND f' 40 MILL POL 2-500 GALLON BM -TOP BASEMENT 7500 GALLON '~-; VAPOR BARRIER LEACHING CHAMBERS P FLOOR, EL-98.03 ' ' SEPTIC TANKSOIL REMOVAL 0 M/4STONE AROUND G�wP Z SEE NOTE P. �A 6, 01 0 �/P NO B4 5EMENT FLOOR PLAN \ m L L'�CU T 1 LONF c 6 ELLOlI R , c /s 'I '� SEtJCKFT RD _- ~ L OCUS MAP I FND 0 0 IO 20� ry}- 40 LEGEND \b . h 5 HEALTH dEPr. ® CB CONCRETE BOUND -W WATER L 1 NE O HYDRANT -G GAS L / NE OHW- OVER HEAD WIRES LIGHT POST -E- UNDERGROUND ELECTRIC LINE -T- UNDERGROUND TELEPHONE LINE - CTV- UNDERGROUND CABLEV/S/ON LINE +40.4 SPOT ELEVATION -40-- EXISTING CONTOUR 40I PROPOSED -CONTOUR DES / GN CR / TER / A : GENERAL NO TES DES I GN FLOW: 3 BEDROOMS AT 1/0 G.P.D. PER 1. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION BEDROOM EOUAL S 330 G.P.D. OF THE SEWAGE DISPOSAL SYSTEM ONLY. NO GARBAGE GRINDER. 2. VERTICAL DATUM IS ASSUMED. FOR BENCHMARKS SET. SEE SITE PLAN. SEPTIC TANK REOU/RED: 330 G.P.D. X 200x - 660 GAL. 3. ALL CONSTRUCTION METHODS AND MATERIALS AND SEPTIC TANK PROVIDED: 1500 GAL. MIN. MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS.. D.E.P. TITLE 5 AND LOCAL SOIL ABSORPTION SYSTEM REOUIRED: BOARD OF HEALTH REGULATIONS. DES / GN PERC RATE l 5 M/ N/ I NCH SOIL TEXTURAL CLASS - 1 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER EFFLUENT LOADING RATE - 0.74 GPD/SF AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER 330 GPD / 0.74 GPD/SF - 446 S.F. REOUIRED THAN 4' IN DEPTH SHALL ,BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. PROVIDED: 2-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-471 S.F. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR 471 S.F. x 0.74 - 348 G. P. D. APPROVED EQUAL. SO l L TEST P l T DA TA ® 6. SEPTIC TANK AND D-BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. bm INDICATES v INDICATES BOTH SHALL BE WATERTIGHT. D-BOX SHALL BE WATER PERCOLATION = OBSERVED TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE TES T GROUNDWATER OUTLET. TPI 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. HORIZON TEXTURE COLOR 1-888-DIG-SAFE AND THE LOCAL WATER DEPT. 0 95•8 FOR LOCATION OF UNDERGROUND UTILITIES. Q LOAMY IOYR SAND 2/2 8, EXISTING CESSPOOL TO BE PUMPED DRY. REMOVED 95.1 LOAMY lOYR B AND BACKFILLED WITH CLEAN SAND. � SAND 4/6 9. ALL UNSUITABLE MATERIAL IA A B HORIZONS, Cl C / MEDIUM IOYR C2 LAYERS) ENCOUNTERED BELOW THE INVERT OF THE SAND 5/6 LEACHING FACILITY TO BE REMOVED FOR A DISTANCE 52. .............................. ;........ 91.5 OF 5' AROUND AND REPLACED WITH SAND 1N C2 SANDY IOYR ACCORDANCE WITH TITLE 5. LOAM 5/6 80'.......................................... 89. 1 C,§ COARSE IOYR SA ND _ 7/4 NO WATER I28 ' 85.1 DATE: DECEMBER 1/. 2008 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE ' i 1�;1 0� PERC RA TE: C 2 M / N/ I NCH ASSUMED IN C3 LAYERf QVIL No. 354 , 9V4 =Otttll ffcm?Tlth� ID�e p -a K ' L, f� Ida, Liate 1�l1 S E P 7- A/ 2 5 E-M B ,A S S Y L ,A /V E. M,A P / 5C E L 4 4 PREP,ARE_ DFOR 7-/-/0",45 2 / V / /VY-ARO ROAD. BURL / /VOTO/V . CT 000 / 3 SC,AL E : / - 20 BECEMBER 23 . 2008 EAGLE SUFRVEY I NG I NC 923 Route 6A Ya rmou t hypo r t MA. 02675 (506) 362-8 1 32 (508) 4-32-5333 -tl