HomeMy WebLinkAboutEngineers Report 03-16-2015 MICHELE CUDILO, P.E. Consulting Structural Engineer Centerville,Massachusetts 02632-1979•(508)771-7601 •Fax(508)771-7163 mcudilo@comcast.net March 16,2015 Town of Yarmouth Building Dept. 1146 Route 28 So.Yarmouth,MA 02664 Attention: Mr.Andrew Arnault • Building Inspector RE: 780 CMR 1001.3.2 Testing and Certification,Mass.Bldg.Code Red Jacket Resorts Red Jacket,So.Yarmouth,MA Dear Mr.Arnault, Please be advised that the above captioned project has been inspected on November 4,2014 and again on this date to view the work completed. This office has inspected all exterior bridges,steel or wooden stairways,fire escapes and egress balconies for structural integrity and safety,and finds them adequate,as amended. I trust that the above addresses your needs at the present time. Should you have any question on any of the above,please do not hesitate to call. /ter y, attaichele Cudilo,P.E. /2013-116 . cc: K.Smith V)., orM4�GY c`5 ist1T4 S4L .N � C� MICHELE CUDILO, P.E. Consulting Structural Engineer 123 Cottonwood Lane,Centerville, Massachusetts 02632-1979•(508)771-7601 • Fax(508)771-7163 mcudilo@comcast.net October 21,2014 Mr. Kenneth Smith Red Jacket Resorts 291 South Shore Dr. So.Yarmouth, MA 02664 RE: Egress Inspections Dear Ken, The following items were observed during Site Observation 01 on October 14,2014,and require follow-up construction,as discussed with Robert Delaney,Assistant General Manager. Note that exterior stairs and balconies that are more than 5 years old do not have to comply with latest requirements(listed below),but be in repair for safety. This inspection was partial and will be resumed on November 4,2014 RED JACKET Exterior Pool Area 1. Exterior Handicap ramp into RHS building from POOL AREA:,bottom decking loose;refasten. 2. LHS electric enclosure rail top loose;refasten. Rooms 222,224: 1. Bottom Baluster Rail connection to posts: reinforce w/L-clip brackets or screws to tighten connection Rooms 245,143 1. Top Rail connection splintered;sand smooth or paint 2. Decking at waterfront split: remove and replace. RHS Waterfront Stair to Beach 1. (3)cupped treads: remove and replace 2. Upper stringer: patch with screws 3. 2 stair up from patio: reset level LHS Waterfront Stair to Beach 1. Split tread: remove and replace Residence#2 1. Left side bottom tread: reinforce or replace 2. Top rail: sand smooth or paint Residence#9,10 1. Top rail 2x6: sand smooth or paint Continued Egress Inspections Red Jacket Resorts,South Yarmouth,MA October 21,2014 Page 2 Front Entrance 1. Wheelhouse 1 deck at 2"d floor: mahogany decking: remove and replace where indicated RIVIERA LHS Building Entrance 1. Handicap ramp: 18"height handicap rail on LHS disconnected at baluster: refasten Upper Waterfront Inaccessible: provide keys for entrance from rooms. Loose Ballusters 1. Reattach (4)loose ballusters with screws at Rooms 238,233, 226, 225,224. The following criteria are required in your future maintenance. Any newly constructed rails shall meet the current criteria: 1. Height of Rail at upper floors: 42" above decking; 2. Spacing between balusters: 4" clear max.; not ladder-type; 3. Max.triangular space between stair parts: 6" sphere. 4. All components shall be capable of withstanding a 200 lb.load in any direction. 5. Height of rail above the leading edge of stair tread: 42" Should you have any questions on any of the above,please do not hesitate to call. Please call for final review of the above corrected conditions in the field for final observation. Sincerely, \ZµoFMgssgc MICHELE CUDILO a / Michele Ctudilo, P.E. o STRUCTURAL y /2013-116 No 34774 O Q 9FQISTEP�nth.' vSS►ONAL ECG