HomeMy WebLinkAboutAir Leakage Report 09-04-2018 (A
R?r+
HOME ENERGY RATERS LLC
/skie ) in
it BUILDING PERFORMANCE TESTING
RECEIVED
Air Leakage Report I SEP 13 2018 j
BUILDING DEPARTMENT
40 Crosby st. Exit Test Mode By
Yarmouth Depressurization
09/04/2018 Test Pressure
50.0 Pascals
Test Equipment
2015 IECC Energy Code Minneapolis
Total Air Leakage Or Air Changes Per Hour Gauge
2214 2.28 _ •
Conditioned Volume1#1=---" -x
`
58150
This project meets the criteria for the following:
2009 International Energy Conservation Code
2012 International Energy Conservation Code
2015 International Energy Conservation Code
180 STATE ROAD SUITE 2U SAGAMORE BEACH,MA 02562-(508)833-3100-ENERGYCODEHELP.COM-INFO@ENERGYCODEHELP.COM
powered bygoconvos www qocanvas corn 3A058CB8-A7FB-4564-A6C3-6E93592CODA2
1p
;cc-7Ft , %NI HOME ENERGY RATERS LLC
pi z ,9 P BUILDING PERFORMANCE TESTING
Ventilation Report
Ventilation Tests
Fan Location ; ` • , Fan CFM Fan Timer Run,Time-
lstfloor 77 24 hrs. �+
c z_v
:a _3
;gymfle
. aas
aoii ,
1st floor 53 24 hrs. "'F=
igga
aas
rt"--
own
180 STATE ROAD SUITE 2U SAGAMORE BEACH,MA 02562-(508)833-3100-ENERGYCODEHELP.COM-INFO@ENERGYCODEHELP.COM
powered bygcorwas www oocanvas corn 3A058CB8-A7FB-4564-A6C3-6E93592C0DA2
•
jSq(f yr „[ HO E E lERGY RATERS LLC
N er t. BUILDING PERFORMANCE TESTING
Compliance Option it:
Follow these steps to determine compliance for the tan Airflow.
1) Determine the floor area of the conditioned space of the home.(Ase)
2) Determine number of Bedrooms.(So)
3) insert these number in the formula Below:
Fen airflow(CFM).OAMAllow+7.5(Ner+t)
Fan Airflow for Homes with Average Air Leakage
Floor Area(ft2) No.Of Bedrooms
0-1 2-3 4-5 6-7 >7
<1500 30 45 60 75 90
1501-3000 45 60 75 90 105
3001-4500 60 75 90 105 120
4501-6000 75 90 105 120 135
6001-7500 90 105 120 135 150
>7500 105 120 135 150 165
Fan airflow Is CFM.