Loading...
HomeMy WebLinkAboutEngineered Plans - 2018r f eemit valid for REPklt or 5vri'tt' SYSTEM NLY due to State and i ocat, septo- variances. ard.of Ne9tth review And apprUYal a n•yuired for n futpre add tionVrenr+xntionsratr+•w al ins to �/ ewsge t rci► 46e andlor stt ucturesl¢�+elhn�.,�0 Pond Y;airmo t H�afth Departnw*TER SURFACE EL.=B3.Of 0' 82.93 83,01 _ ame -DODA.--"- -----___ ------ ------ ----- N 0.— — _.--. —�— ter--"'—'� CL ,T - — — — — — — + 86.96 -----------------' beach - 7.20 a 88,95 + 89,43 f' Long Pond P N LOCUS )� Pie oke�o�d L Great Pond Dr M od Rd o > 6Lakewo 3 N Y O Q p = N = C O V �a 3 O ,2 - a �°o Town RpOiE 628 Off/C65 LOCUS MAP NOT TO SCALE ��i+•90r43• 92.56 + 1 - - - - - ~ � STONE RET _-96:89 —/ WALL --_ x 92.96 O�J `s, ____ EXISTING SEPTIC TANK LOT A7 - _� TOP OF TANK, EL.=94.9 � 97,06 INV. (OUT)=93.55± 8�920f S.F. ' PK SET 95.62 "I' 94.16 EXISTING LEACH PITS TO BE PUMPED, FILLED W/ 94'7 SAND &ABANDONED. DECK �� x 95.59 x 96.60 �t _ EC'fSVC-96 -- -95.� 96 95.81 L EXISTING 96.44 0 HOUSE(#31) FF=97.81- 96.40_- - 96.40• 'J o 97,09 OPSLEFi.� age of Mgss9�yG o PETER T. McENTEE CIVIL No. 35109 ' VC. � 7. W �--i i + W 9 FL ®POLE 9 97 x 98.67 p( �8722 1 + 8.30 �`� GS / ...' :.N' :..:: N �( BRz. a WAY 9870 + PLAN REVISION 9,(5/18 1) ADD SLEEVED WATER SVC. 2) SPECIFY H-20 CHAMBERS 3) ADD MAP ID 4) SHOW SEWER HOUSE TO TANK 5) CALL OUT BENCHMARK OWNER OF RECORD MARKLE, HARRY MARKLE, HARRY TRS 31 LAKELAND AVE. SOUTH YARMOUTH, AM 02664 MAP ID: 59--48 LEGEND — — 98 — — EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE —dGW-- UNDERGROUND WIRES W EXISTING WATER SERVICE W PROPOSED WATER SVC. (SLEEVED) G EXISTING GAS SERVICE TEST PIT i .9. 3D� V. .` p 98.48 m .". AVE .,• - V SAW CUT ANO PAT PAVED DRIVEWAY GARAGE 0 2 x 1 0.00 �99,46 to x 99.66 98.78 l 99.05 ` . TP 0 >: i99.64 99,98 5•P': BDH LOTS A7 • & A8*•'. QRop 100.50 COMBINED. •AT�EA=20,040t SF. 25 99.54 6' BENCHMARK + GARDEN TOP OF CONC. BOUND 98.27 + QC22� EL.=100.52 '. .•'99.23 10 PROPOSED VENT ce Q5 CONSULT WITH OWNER REGARDING PLACEMENT 9812 NOTE: HOUSE LOCATION TAKEN FROM "PLOT PLAN OF LAND, LOCATED AT 31 LAKELAND AVE., SO. YARMOUTH, MA" BY YANKEE LAND SURVEY CO. INC., DATED APRIL 19, 2013 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 31 LAKELAND AVE., SOUTH YARMOUTH, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. 1''=20' P.T.M. 199-18 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO, (508) 477-5313 8/7/18 P.T.M. 1 Of 2 SEPTIC TANK INSTALL RISERS & COVERS OVER INLET & PROPOSED D-BOX OUTLET AND SET TO 6" OF FINISH GRADE FIRST FLOOR=97.8t INSTALL RISER & WATERTIGHT COVER SET TO 6" OF GRADE F.G. EL.=97.3f EXISTING F.G. EL.=97.0t 1 14" 48' LIQUID - LEVEL ADD I GAS BAFFLE L=52' ® S=1% (MIN.) 4'SCH40 PVC NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES & INVERTS EXITING HOUSE, PRIOR TO INSTALLATION. 2) D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. F.G. EL.=99.5t L = 13' ® S=1% (MIN.) 4'SCH40 PVC INV.=92.80' PROPOSED \-INV.=92.63 4=93.50 D-BOX INV.=92.50 TOP CONC. ELEV.= 93.6f BREAKOUT ELEV.= 93.00 INV. ELEV.= 92.50 NOTE: TO PREVENT BREAKOUT, FINAL GRADE SHALL NOT BE AT, OR BELOW, EL.=93.0 FOR A DISTANCE OF 15' FROM THE EDGE OF THE PROPOSED S.A.S. PROPOSED S.A.S. INSTALL RISER & COVER OVER ONE CHAMBER AND SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT r F.G. EL.=99.5t MAINTAIN 2% SLOPE 4' 4.8' 1 4' EFFECTIVE WIDTH = 12.8' BOTTOM ELEV.= 90.50 4' OF NATURALLY OCCURRING PERVIOUS MATERIAL 5' (MIN.) ABOVE G.W. BOTTOM OF TEST HOLE, EL.=87.6 z ESTIMATED HIGH G.W., EL.=83.7 VERIFY SOILS TO EL.= 86.5 DURING INSTALLATION SEPTIC SYSTEM PROFILE GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: -310 CMR 15.405(1)(b): 1) A 3' variance to the 3' maximum cover requirement, for up to 6' of max. cover. S.A.S. shall be H-20 and vented. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE_BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON AN ASSIGNED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WITHIN 150' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOMS SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 G.P.D. DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO -not allowed with design LEACHING AREA REQUIRED: (330) = 445.9 S.F. .74 EXISTING SEPTIC TANK: 1000 GALLON CAPACITY PROPOSED D-BOX: 1 INLET, 3 OUTLETS, H-20 RATED USE 2-500 GALLON LEACHING CHAMBERS IN SERIES SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F. BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F. TOTALAREA: .............................................................. 471.2 S.F. DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD 2x8.5'=17.0' _1_ 11VE LENGTH = 25.0' LEACHING SYSTEM SECTION S.A.S. - 2" LAYER OF 1 /8• TO 1/2- DOUBLE WASHED STONE (OR APPROVED FILTER FABRIC) " TO 1-1/2" DOUBLE WASHED STONE if Y WAY DR�WP P ABED i 71 ? 52'9 i 29.3' 5 3g ), 7.4' S 25 SEPTIC LAYOUT SOIL LOG DATE: JULY 11, 2018 SOIL EVALUATOR: PETER McENTEE PE WITNESS: AMY VON HONE R.S. HEALTH AGENT ELEv. TP-1 DEPTH 99.6 0" A LOAMY SAND l0YR 4/2 98.9 B g" LOAMY SAND 10YR 5/8 96.4 38" C PERC 42"/60" MED. SAND 2.5Y 6/4 87.6 1 144" NO GROUNDWATER ENCOUNTERED, PERC RATE <2 MIN/IN. LONG POND WATER SURFACE EL.=83.0 USE INDEX WELL MIW-29, ZONE A WATER LEVEL=6.8 (JUNE 2018), ADJUSTMENT=0.7', ESTIMATED HIGH G.W., EL.=83.7 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 31 LAKELAND AVE., SOUTH YARMOUTH, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 Engineering by: SCALE DRAWN JOB. NO - Engineering Works, Inc. N.T.S. P.T.M. 199-18 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 8/7/18 P.T.M. 2 Of 2