HomeMy WebLinkAboutEngineered Plan - 2018TOP OF FOUNDATION ELEV=102.86 .4 9" MIN. COVER 36" MAX. COVER 22' OF 4" SCH 40 PVC, S=0.02C MIN. PROPOSED 1,500 GALLON INV.=100.53 10" REINFORCED CONCRETE SEPTIC TANK (H10) -14 INV.=98.90 LOCUS SCALE 1 "=1000' 1 ti U 0 Zee )bN S TEE OG TEE WITH GAS BAFFLE (CENTERED IN TANK OPENING) PROPOSED SEPTIC TANK RISERS TO BE BROUGHT TO, WITHIN 6" OF GRADE 4' OF 4" SCH 40 PVC, S=0.010 -----_______ MIN INV.=98.65 INV.=98.61 / LEVEL STABLE BASE CONSISTING OF 6" CRUSHED STONE PROPOSED 3-OUTLET DISTRIBUTION BOX (H10) PROPOSED DISTRIBUTION BOX RISER ON D-BOX TO BE BROUGHT TO WITHIN 6" OF GRADE PROVIDE SPEED LEVELERS ON OUTLETS RISER ON CHAMBERS TO BE BROUGHT TO WITHIN 6" OF GRADE 9" MIN. COVER 36" MAX. COVER 14' OF 4" SCH 40 (LONGER RUN) A LEV.= PVC, S=0.010 MIN. --__-- ----- mmm0 m��I INV.=98.44 [::] 1:3 ED [f] I IM ED IQ 0 [=1 I INV.=98.30 F=I__ 4' 4.83' X 8.5' LEACHING CHAMBER 4' (SEE SITE PLAN FOR ORIENTATION) (2)-500 GALLON H-10 LEACHING CHAMBERS j PROPOSED SOIL ABSORPTION SYSTEM SYSTEM PROFILE NOT TO SCALE SCREENEDI DECK PORCH BATH BATH KITCHEN BDRM GARAGE LIVING DINING BDRM FLOOR PLAN NOT TO SCALE C8098.96 EF,� BENCHMARK \ EcT r0 PK NAIL SET IN PAVEMENT r6O9.32 N WAy ELEV.=91.08 _EDGE or �/ EN100.15100.270-`100.00 A,p3.S4. 5,0p, �X 100.85 jr- 3 LOT 4 1 100.�2 14,789 SQ. FT. f w ' 1 0.34 ACRES t / N 1' , _ d1.63 i---- 102 � 102.05 wNIF DANNY F HERNANDEZ j / / ///// // ~o MAP 90, LOT 36 j o ,l 15 REFLECTION WAY j / XISTz T p DTYL"LLIN z T.O.F._ OOM G rn / 102. � � / / / 86' � APPROXIMATE LOCATION / / 102.48 I OF EXISTING GAS SERVICE w .< 100.28 DECK in � X 102.36 2 CORNER OF o r00 �// m BULKHEAD _n \ ELEV.=102.85' 1 o >�99.15 ��\ 1C2.19. x o - N/F Z \ 101.42� o o ROBERT B& JOAN M KILROY j '6 N 0 PROPOSED �T 102.16 MAP 90, LOT 36 EDGE OF �` c� �'r o 0 t 2' 2 1,500 _GALI,A I 23 REFLECTION WAY LAWN �99.61J 2�� \ O \ PRECAST,-SEPTfC TANK ! 102.11 1 99.59 `� �3-OUTLET ( / \ a DISTRIBUTION :'; O ...:�'t� 102.16 BOX 1`:::.::. -,jm o tN EXISTING CESSPOOLS TO w =►"_' ;~.'t BE BACKFILLED WITH z_ LIMIT OF STONE t 25•0' ---� �102.21'x CLEAN SAND AND : 101.12 r RESEW X 101.0; x �6 ABANDONED OR REMOVED (2) PROPOSED �_ __ TP I t 151'# 102.04 FINAL GRA T0MATCH H a. 500-GALLON PRECAST CONCRETE TO CATCH 102.40 X -EXISTING GRADES a_ CHAMBERS BASIN IN TERN ROAD z 101.64X STOCKADE FENCE x 101.12 1 1.76 N/F S 89'54'57" E 106.87' CAROL A REED MAP 190, LOT 51 27 TERN ROAD IP(FND) TO I/ CORNER X 102.03 ,/ 2.10' 102.79 SITE INFORMATION ADDRESS: 19 REFLECTION WAY SOUTH YARMOUTH, MA 02664 AP 90/37 DEED REFERENCE: 10439/258 ELEV.=101.80 MAX DESIGN CALCULCATIONS 2" OF I" PEASTONE OR 8 OZ. NON WOVEN DESIGN FLOW GEOTEX11LE 110 GALLONS/DAY/BEDROOM X 3 BEDROOMS = 330 GALLONS/DAY 8.80 TANK CAPACITY 200%DAILY FLOW = 660 GALLONS; USE PROPOSED 1,500 GALLON TANK 2' DEPTH OF 11" DOUBLE REQUIRED LEACHING CAPACITY `WASHED STONE DESIGN PERC RATE = < 2 MIN/INCH -EV.=96.30 330 GPD / 0.74 GALLONS PER DAY PER SO. FT. = 445.94 SQ. FT. PROVIDED LEACHING CAPACITY 5' MINIMUM SEPARATION TO BOTTOM .AREA = 12.83'. X. 25.00: = 320.75 SQ.- FT_ - SEASONAL HIGH GROUNDWATER SIDE AREA = 75.66' X 2.00' = 151.32 SO. FT. 472.02 SO, FT. NO WATER WAS OBSERVED DURING THE TEST HOLE EXCAVATIONS. GPD PROVIDED = 349.33 GPD BOTTOM OF DEEPEST HOLE ELEV=91.30 GENER A L NOTES TP- 1 0" 101.30 A LOAMY SAND 1OYR 3/1 9" B 100.55 LOAMY SAND 10YR 5/6 35" C 98.38 MED SAND 10YR 6/4 PERC 0 64" 120" ` , 91.30 PERC RATE: < 2 MIN/IN. DATE: AUGUST 23, 2018 PERFORMED BY: ASA MINTZ, PE WITNESSED BY: AMY VON HONE, R.S. SOIL PROFILE NOT TO SCALE LEGEND 1. NONE OF THE SUBJECT PROPERTY IS WITHIN THE LIMITS OF A FEMA FLOOD HAZARD ZONE AS SHOWN ON PANEL NO. 25001 CO591 J, EFFECTIVE DATE JULY 16, 2014. 2. THE SITE IS NOT LOCATED WITHIN A ZONE 11 AREA. 3. THERE ARE NO STREAMS OR WETLANDS WITHIN 100-FEET OF THE PROPOSED -SUBSURFACE SEWAGE DISPOSAL SYSTEM. 4. VERTICAL DATUM IS ASSUMED 5. ALL CONSTRUCTION MEANS AND METHODS SHALL CONFORM TO 310 CMR 15.00 STATE REGULATIONS AND LOCAL BOARD OF HEALTH AND BUILDING DEPARTMENT REGULATIONS. 6.. ALL JOINTS IN THE. TANK AND .DISTRIBUTION -BOX .SHALL. BE _MADE WATERTIGHT THROUGH THE USE OF ASPHALT OR SYNTHETIC POLYMER SEALERS OR HYDRAULIC CEMENT. 7. SYSTEM COMPONENTS SHALL BE H-10 LOADING 8. DIGSAFE AND LOCAL UTILITY COMPANIES SHALL BE CONTACTED PRIOR TO ANY EXCAVATION OCCURRING. 9. LOCATION OF 'UTILIT(ES ON THIS PLAN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD. THE ELEVATION OF THE BUILDING SEWER SHALL BE ---- - --_ --- --- - VERIFIED-PRIOR--TO--THE- INSTALL -OF ANY-SYSTE-M =COMPONENTS -. 10. THE SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE DESIGN ENGINEER 2 DAYS PRIOR TO BEGINNING INSTALLATION OF THE SYSTEM TO ALLOW FOR SCHEDULING OF INSPECTIONS 11. WHERE ..APPLICABLE,..UNSUITABLE .MATERIAL .(A..& .B HORIZONS) _ENCOUNTERED / BELOW THE INVERT OF THE INLET TO THE SOIL ABSORPTION SYSTEM, SHALLMr BE REMOVED TO A DISTANCE 5' AROUND THE SYSTEM AND BROUGHT BACK TO THE APPROPRIATE ELEVATION WITH CLEAN SAND PER MASSACHUSETTS 310 _ yGN CMR 15.00 REGULATIONS. 12. EXISTING CONDITIONS GROUND SURVEY PERFORMED BY DEMAREST LAND NOJ 5165E SURVEYING, AUGUST 23, 2018. SURVEY CALCULATIONS PERFORMED BY PAUL o E. SWEETSER, PLS. RFGtsTE�O G�� S.StO1,lAL� 13. THIS DESIGN DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER PROPERTY LINE (; 35 ---------------104--------------- EXISTING CONTOUR q N� SUR - - -104 - - - PROPOSED CONTOUR EXISTING FENCE -X--X X -OHP EXISTING OVERHEAD UTILITIES W EXISTING WATER LINE CBL EXISTING CABLE LINE G EXISTING GAS LINE E PROPOSED UNDERGROUND ELECTRIC TP-1 LOCATION OF TEST PIT/PERC TEST 99.76 X EXISTING SPOT ELEVATION _QFH EXISTING FIRE HYDRANT UP-0- EXISTING UTILITY POLE BH BULKHEAD 101.50 PROPSED SPOT GRADE IVA 4 CRESTVIEW DRIVE EAST SANDWICH, MA 02537 PHONE: -(508) 400-2365 SITE ]DESIGN, LL�Cn rc T Residential Site Design and PerFmitting