HomeMy WebLinkAboutEngineered Plan - Rev. 2017*9.5' SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE EL. 13.1' 10.9' MINIMUM 75' OF COVER OVER PRECAST 2'0 PRECAST H-10 NOTE: 2" MIN. WALL RISERS (TYP.) THICKNESS REQUIRED (NOT TO SCALE) 4 0SCHI PVC , 6" MIN. SUMP PIPES LEVEL 1ST 2' 12" MIN. INT. DIM. 10" 1500 GAL H-10 14" 8.9 6' TEE SEPTIC TANK TEE $ 71'jl' ; OOOO0000000 WATERTEST D'BOX GAS BAFFLE.., ?900o0? FOR LEVELNESS 4' LIQ. LEVEL (ACME OR EQUAL) 8.44' J000000�OV0 0�000 O O O O O`O 000 O O O 0008L • 000000000000000000000000000000000000000000000 „000000002*0 00,0700000000000 POnOn0O,0„0000000. 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. /PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE 2% SLOPE REQUIRED OVER SYSTEM Z 10.01 ( 2.5 % SLOPE MIN.) (1 % SLOPE) (1 % SLOPE) FOUNDATION 17' SEPTIC TANK 7' D' BOX 6' - *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND as - EXISTING CONTOUR X 99 1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 2Y� SLOPE OF GROUND CQ) UTILITY POLE r FIRE HYDRANT If NOTE: NOT ALL SYMBOLS MAY APPEAR 1N DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: PHIL RENAUD DATE: 9/22/2016 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS Q ELEV. Olt8.5' A LS 1OYR 4/2 20" B LS 39" 1OYR 5/8 5.2' PERC _ MS G-W ADJ. DATA: - WELL: MIW 29 1OYR 7/6 ZONE: A ADJ: 2.6' AUGUST 2016 120" I I -1.5' GROUNDWATER ENCOUNTERED AT 96" = EL. 0.5' DCE # 1 6-303 ZONING SUMMARY ZONING DISTRICT: R-25 DISTRICT QUICK4 PLUS STANDARD LOW PROFILE UNITS OVERALL DIMENSIONS TO OUTSIDE OF UNITS: 33' X 8.5' (NO STONE PROPOSED) LEACHING FACILITY REQ. EXIST. PROP. MIN. LOT SIZE 25,000 6072 6072 MIN. LOT FRONTAGE 150' 80/78 80/78 MIN. FRONT SETBACK 30 23.6' 23.9' (or 30% depth of lot) MIN. SIDE SETBACK 15' 13.1' 15.1' MIN. REAR SETBACK 20' N/A N/A MAX. BUILDING COVERAGE 25% 16.8% 18.6% BUILDING HEIGHT 35' 14.55' 34.9' (ABOVE AVG. OF NAT. GRADES 9.9) 1� BENCHMARK: CEMENT BOUND = 12.5' NAVD88 LOT 7A 6,072 SF 7 i �'// D E S I I' ,. 0�~ DI��'I _IFL 5' 1 GROUNDWATER ADJUSTED EL. 3.10' S NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING (1-888-344-7233) AND VERIFYING IGSAFE THE LOCATION OF ALL UNDERGROUND & LOCUS . MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF , WORK. SCALE 1 =2000 t 11. ANY UNSUITABLE MATERIAL ENCOUNTERED ASSESSORS MAP 22 PARCEL 17 SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X (0.2 12. EXISTING LEACHING FACILITY SHALL BE PUMPED PCT ANNUAL CHANCE FLOOD HAZARD) AS AND REMOVED OR PUMPED AND FILLED WITH CLEAN SHOWN ON COMMUNITY PANEL #25001CO569J SAND. DATED 7/16/2014 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED 2% MIN. SLOPE OVER SYSTEM 4" LOAM & SEED 0.0 PROPOSED 3 BEDROOM DWELLING -\ I / 21 „t ' CAP ON CAP STONE UNITS =111 x 5 1/4" DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD iLlir_ _ _Ij1-III Fiberglass Fiberglass USE A 330 GPD DESIGN FLOW 9" COVER 1=11IIjl_11 __ =11llil_il-- Pins AS 5'MIN. MAX SEPTIC TANK: 330 GPD (2) = 660 6" vARIEs \� J J USE A 1500 GAL. SEPTIC TANK PEASTONE COARSE SAND BACKFILL. AGAINSTT _\NALI_ LEACHING: 40 MIL LINER FROM TOP PEASTONE/WALL 4 73 SF A F x 4' LEN18 92 SF PER GTH = TO 12" BELOW GRADE KEYSTONE OR EQUAL RETAINING WALL UNITS \ QUICK4 PLUS STANDARD LP UNIT 18"X8" SET WITH 1" BATTER PER ROW FIBERGLASS PINS REQ. 6"X30" Crushed Rock or 330 GPD/0.74 GPD/SF = 446 SF LEACHING Unreinforced Concrete REQ'D Leveling Pad req.. �^ 446 SF/18.92 SF/UNIT = 23.6 UNITS RETAINING WALL CROSS SECTION NOT TO SCALE THEREFORE, USE GRAVELLESS SYSTEM OF (24) QUICK4 PLUS STANDARD LP UNITS IN FIELD CONFIGURATION OF 3 ROWS OF 8 UNITS 24 UNITS x 18.92 SF/UNIT = 454 SF> 446 SF 454 SF (0.74) = 336 GPD (OK) 7 SH L / D VE E-LOCATE WATERLINE AS SHOWN MIN. 10' FROM SEPTIC COMPONENTS _ p PROVIDE 115' OF 40`MIL LINER AT 5' i OFF SAS IN AREA SHOWN. TOP AT ELEV. 8.8 BOTTOM AT EL. 4.8'f (Z). 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, j DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF A10 AMR 15 255(3) Scale: 1 "= 20' 0 10 20 30 40 50 FEET Yr-ri-moeth Health Departr unt A TITR 1, � y i acne Date APPROVED DATE BOARD OF HEALTH ' MA SITE PLAN OF #3 BAY ROAD WEST YARMOUTH, MA PREPARED FOR DATE PAUL THOMPSON DATE: 7-26-2017 REV.: 8-28-2017 off 508-362-4541 I fax 508-362-9880 downcope.com down c41p4 en 1869LO inb', iac. civil engineers Ion d surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 16-303 j . . s