Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 2018LOCUS DATA CURRENT OWNER 182 FOREST LLC. PLAN REFERENCE 220-149 DEED REFERENCE 31434-35 ZONING DISTRICT 220-149 FLOOD ZONE "X" ASSESSORS MAP 86 PARCEL 15 OVERLAY DISTRICT ZONE II LOT AREA 71,706f S.F. SITE & SEWAGE REPAIR PLAN SYSTEM II #182 OLD TOWNHOUSE RD. IN YARM OU TH, MASS DATE: AUGUST 27, 2018 REV: OCTOBER 15, 2018 APPLICANT: MARDIN REALTY, INC. P.O. BOX 394 MALDEN, MA 02148 781- 484- 8413 SHEET 1 OF 3 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS. SU RVEY@YAH 00. COM N 84-4813511 E 99.56' m UPOLE PROPOSED S.A.S. (3)1 CHAMBERS WIT 4' OF STO AL6 AROUND LPOLE II 0 40 60 80 I x w GRAPHIC SCALE: 1 INCH = 40 FEET i i N 84'48'35� E SEPTIC'"------ ` TANK G GW� SYSTEM III \ EXISTING < FLOW \ \ 353 GPD <c \� s OFFICE 2425 S.F. o S SEE RETAIL SH. 2 STORE , 1,400 S.F. � ` \ o ROP. �L OFFICE \ 1400 S.F:` i RETAIL a \ STORE \ 1, 400 S. 1\ \ ` SYSTEM I EX. FLOW ` 1,920 GP 1 OTS 168�-171 ; ,l F 71,706t / ��SIGN� LPOLE J> — w w �—Te WAY w 0_ ��.J ' ' 37 r LEACHING PITS SEPTIC TANK GREASE TRAP E LOCUS LOCUS MAP NOT TO SCALE: 18-0115-01 EDWARD A STONE Pet'mit valid for REPA1R' 0*.. S1 ONLY, due to State and local Board of health review and ali}trov:v any future add itions/rewrvations I:— �• sewage facilities and/or structures/dw, "• p» LEACHIN Box iLr) EA�I�<L�IG3MCA 7n' IT e w—F—w w w w OLD TOWNHOUSE ROAD Yarmopth Health Dcty*ttp): )WPRO V EDP, :Date ^ 0 20 30 40 GRAPHIC SCALE: 1 INCH = 20 FEET 18-0115-01 SITE & SEWAGE REPAIR PLAN SYSTEM II #182 OLD TOWNHOUSE RD. IN YARM OU TH, MASS DATE: AUGUST 27, 2018 REV: OCTOBER 15, 2018 APPLICANT: MARDIN REALTY, INC. P.O. BOX 394 MALDEN, MA 02148 781- 484- 8413 SHEET 2 OF 3 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS. SU R VEY@YAH 00. COM W0 r/j LPOLE\ 4R BENCHMARK SYSTEM III CORNER OF EXISTING FLOW CONC. 37.6 353 GPD LPOLE EXISTING LEACHING PITS TO 2n BE PUMPED CRUSHED AND 21.9' REMOVED FROM SITE IN 33.4' ACCORDANCE WITH TITLE 5. 1,000 GALLON\ PROPOSED S.A.S. (3) SEPTIC TANK H-20 CHAMBERS ` 11 TOREMAINi m WITH 4' OF STONE Do S S ALL AROUND. M o BITUMINOUS m CONCRETE h H I 1 LPOLE / I � c/ PROPOSEDI VENT 9�c� I I I I I � NOTE: / MCONTRACTOR TO CLEA%OUT CATCH B ISIN I I I BITUMINOUS I I CONCRETE I 1 I � 20.5 �rZ 0 � oo- SYSTEM II o PROPOSED FLOW 427 GPD OFFICE 2425 S.F. 182 GPD 1 33.4' \ PROP 1,000 GALLON H-20 ` SEPTIC TANK RETAIL STORE ��11 1,400 S.F. PROP H-20 �, 70 GPD „DB-9,' F. 0 PROP. OFFICE 1400 S.F. 105 GPD BITUMINOUS CONCRETE RETAIL STORE 1,400 S.F. 70 GPD G o2 SYSTEM 1 EXISTING FLOW �' \ 1,920 GPD TOP OF FOUNDATION ELEV. 37.6 FINISH GRADE ELEV. 36.75 SCH 40 4" PVC INV.= I lU 10"TEE 14"TEE 30.60 INSTALL GAS BAFFLE INV.= TO REMAIN EXISTING 1,000 GALLON H-20 TANK TO REMAIN JOB # 18-0115-01 SITE & SEWAGE REPAIR PLAN SYSTEM II #182 OLD TOWNHOUSE- RD. IN YARMOUTH, MASS DATE: AUGUST 27, 2018 REV: OCTOBER 15, 2018 APPLICANT: MARDIN REALTY, INC. P.O. BOX 394 MALDEN, MA 02148 781- 484- 8413 SHEET 3 OF 3 ld Sk a'awol Mm EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS.SURVEY@YAHOO.COM FINISH GRADE ELEV. 36.6 3*GS= INV.= 2 MIN-3--MAX 30.40 10"TEE 14"TEE INV.= INSTALL 30.34 GAS BAFFLE 4'-0". LIQUID LEVEL PROP 1,000 GALLON H-20 TANK SET ON LEVEL STABLE BASE. RAISE BOTH END RISERS FINISH GRADE TO FINISH GR DE WITH H-20 ELEV. 36.5 ELEV. 36.4 COMPONENTS 7,*S= TOP ELEV 30.82 _ 0.01 10'OS=0.005 00000 0 0 INV.= O O o 0 30.14 °00^Oo o 0 9 OUTLET H-20 DB INV.= 30.07 NEW DB-9 INV.= 29.87 BOT.= 25.69 INV.= 29.82 CONSTRUCTION NOTES: 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. ENGINEER TO VERIFY REMOVAL OF UNSUITABLE SOILS PRIOR TO INSTALLATION OF NEW SEPTIC SYSTEM. 4. NO PARKING OVER SEPTIC TANK IS ALLOWED. GENERAL NOTES: 1, ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 3 OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS OTHERWISE SPECIFIED. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 12, CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. 13. MAGNETIC TAPE ON ALL COMPONENTS. SAVE EXISTING H-20 LEACHING PIT COVERS AND REUSE PROP 'ION 36.2 VENT 00000 0 00000 00000 (3) 5'-0"x8'-6"x3'-0" H-20 CHAMBERS S.A.S. (13.0' x 33.5') 0 c� w a ELEV. 27.82 O O �ui ELEV. 26.8 BOT_ OF HOLE A1W-230/231 JULY 2018, ADJUSTED ELEV. 22.7f * ADDITION DEEP HOLE REQUIRED 0 TIME OF INSTALLATION WITHIN S.A.S. LOCATION 400000 a o 00000 0 0 0 0 O o 0 0 0 0 0 o°00°00 0 oo°oo°°o �-- 4.0'-*-1------ 5.0' I-= - 13.0' I SIDE VIEW DATUM: VERTICAL DATUM: YARMOUTH GIS± BENCH MARK USED: CON. SLAB ELEVATION 37.6 DTH #1 i' INDICATES DEEP TEST HOLE GROUNDWATER ADJUSTMENT DEPTH TO BOTTOM OF HOLE 13.0' VARIANCES REQUESTED TO ALLOW THE PROPOSED SEPTIC TO BE 5.6' BELOW GRADE IN LIEU OF 3'. A 2.6' VARIANCE IS REQUESTED. SYSTEM DESIGN DESIGN FLOW 3825 S.F. OF OFFICE 0 75G/1000 S.F=287GPD 2,800 S.F. OF RETAIL 0 50G/1000 S.F=140GPD 447 GPD REQUIRED SEPTIC TANK (2) TANKS 427x200% +_427x100% ___ 1L281 __ GAL. 1st EXIST. SEPTIC TANK __ 1. (0 GAL. 2nd PROP. SEPTIC TANK-_1,944-_GAL. SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC RATE M <2 ____MIN./INCH LONG TERM APPL. RATE_0.74-GPD/S.F. SIZE OF LEACHING SYSTEM PROVIDED: 427 _ 0.74 SF/GPD = 577 S.F. MIN. REQ. USING H-20 CONCRETE LEACHING CHAMBERS WITH 4' OF STONE ALL AROUND BOTTOM (13.0' x 33.5') = 435.5 S.F. SIDE WALL (13.0' + 33.5') 2x2 = 186 S.F 621.5 S.F. 621.5 S.F.x 0.74 G/SF = 460 GPD 460 GPD PROV > 427 GPD REQ. = 33 GPD RES. NO (GARBAGE DISPOSAL / GRINDER ALLOWED) 144 INDICATES ADJ. G.WATER _ NO OBSERVED G.WATER INDICATES PERC TEST 42" PREVIOUS FLOW SYSTEM 1 1,920 GPD SYSTEM II 822 GPD SYSTEM III 353 GPD TOTAL 3,095 GPD D.T.H. #1 0 DATE: 7/26/18 GROUND ELEV. 38.8 ADJ G.WATER N/A B.O.H. AMY VON HONE, BOH SOIL EVALUATOR ED. STONE, EAS SURVEY BACKHOE OPERATOR. LARRY - ELLIS BROS. SOIL TYPE: PERC RATE: <2 MIN. PER INCH LOADING RATE: 0_74 GAL/SF/MIN 0/A/E LOAMY SAND 10YR 5/1 81 B SANDY LOAM 7.5YR 5 6 22„ ELEV = 36.9 C-1 MED. SAND 10YR 7/6 42" 48" ELEV = 34.8 C-2 COARSE SAND 2.5Y 7/4 NO G.WATER 144" ELEV = 26.8