Loading...
HomeMy WebLinkAboutEngineered Plan - 2018NOTES I SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 1I11.111/1 ILI 7r AC' /'MIM MK70 PAF(`ACT ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 2% SLOPE REQUIRED OVER SYSTEM NOTE: 2' MIN. WALL PRECAST H-10 THICKNESS REQUIRED PROVIDE INSPECTION PORT TO WITHIN 3" OF FINAL GRADE RISERS CTYP.) 4'DSCH40 PVC 2'0 6' MIN. SUMP PIPES LEVEL 1ST 2' 12' MIN. INT. DIM. 2" DOUB�>T WASHED PEASTONE 10" "EXISTING 14" OR GEOTIf ILE FABRIC 34.42' TEE SEPTIC TANK TEE ;00000000000a� WATERTEST D'BOX �o GAS BAFFLE �9a�°o,°q°o$o°' FOR LEVELNESS o o *33.92 go 2' c oa HIGH CAPACITY INFILTRA I UNS liI_7 3/4" TO 1 1/2 " DOUBLE` WASHED STONE ' OVERALL DIMENSIONS TO ❑UTSIDE OF STONE, 39.5' X 6.83' FOUNDATION— EXIST. SEPTIC TANK EXIST. D' BOX EXIST. LEACHING FACILITY ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC 31.92' 5.22' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF BOTTOM TH-I UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY NO GROUNDWATER FOUND 26.7' PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM FOR RE -USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE 99 — EXISTING CONTOUR X 99-1 EXIST. SPOT ELEV. —[991— PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 21., SLOPE OF GROUND C-0b UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: RICK JUDD, R.S. WITNESS: C. STIEFEL DATE: 11 /20/01 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 41 ELEV. 0 36' 0 6" s 1OYR 3/2 11" Bw LMS 42„ 1OYR 4/6 32.5' PERC C M/CS 2.5Y 6/4 112" 126.7' NO GROUNDWATER ENCOUNTERED LICE # 18-251 5' REMOVAL OF UNSUITABLE SOIL REQUIRED' \ AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE PROVIDE 25' OF 40 MIL LINER AT 5' WITH CLEAN MED. SAND, TO MEET -OFF SAS IN AREA SHOWN. TOP AT /-____�SPECIFICAMONS OF 310 CMR 15.255(3) ELEV. 34.5', BOTTOM AT EL. 30.5't 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. tocus � o 1 � a b t� hom Lin �e o O e King's of Way oJaj �oG tPond �a Setucket ,p 0 P / / �cc n Follins Pond CALLINGTDIGSAFE (1-888B 344E 720 3)BAND OR LOCUS M' `p VERIFYING THE LOCATION OF ALL UNDERGROUND & SCALE 1 "=2000't f OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. ASSESSORS MAP 151 PARCEL 49 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE SITE IS NOT WITHIN A ZONE II PROPOSED LEACHING FACILITY. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD .USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 ROq **RE -USE EXISTING 1000 GAL. SEPTIC TANK NOR 48 LEACHING: �\ Ty SIDES: 2 (39.5 + 6.83) 2 (.74) = 137 GPD . _ -._336 - GPD 5_--x- 6.83_ _ (74) - BOTT OM 39_-- — - -- t TOTAL: 455 S.F. 336 GPD USE EXISTING (4) HIGH CAPACITY INFILTRATORS WITH 2' STONE AT SIDES ADD (2) ADDITIONAL HIGH CAPACITY INFILTRATORS WITH 2' STONE AT SIDES AND 2' STONE AT THE END d�v - , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 9 #9 BRAY FARM ROAD NORTH YARMOUTH PORT, MA PREPARED FOR THERESE GORETTI BENCHMARK: BASEMENT SILL DATE: AUGUST 2, 2018 --40.65' NAVD88 1 Scale: 1 "= 20' OF �,� ZN OF MASS gC,sl���N pssgcy� 0 10 20 30 40 50 FEE] DANIEL s 250- BEDROOM` LIVING �o DANIELA. s� off 508 362-4541 OJALA fax 508-362-9880 O � , ROOM BEDROOM i8 CIVIL ' OJi;tJ! �� N downcape.com A No, 40r�80 No.46502 A KITCHEN �.� 1F�.� q R oc,��c q�Fm " �'��Q down c41pe engineering, Inc. N BEDROOM Varmouth lle-0th D. 1", r eat �Q su BATH DINING 6 „SOON E • civil engineers �. land surveyors LEACHING DETAIL ''� ®-i FLOOR PLAN ��� �a;�� ���e 939 Main street � Rte 6A> DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 SCALE 1" = 20' nlnT Tr) grAI1= 18-251