Loading...
HomeMy WebLinkAboutEngineered Plan - 2018LOCUS UTE 28 N � P, 4 KEY: EXISTING CONTOUR: - - - - PROPOSED CONTOUR: ----•-•-----• EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: * UTILITY POLE: -O- FENCE LINE: HYDRANT:.-6- RETAINING WALL: o PARCEL 193-ClATION (5 789 SF) ASSESSORS MAP: 31 PARCEL: 193-Cl PLAN BOOK: 287, PAGE: 2 M8-49 MMMMMM IMMMMMMI IMMMMMMI SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 1 BEDROOMS AT 110 GAL / DAY = 110 GAL / DAY SEPTIC TANK: 110 GAL / DAY x 2 DAYS = 220 GAL USE 1000 GALLON SEPTIC TANK (EXISTING) LEACHING AREA: (3 BEDROOM DESIGN, MINIMUM) USE 24 INFILTRATOR QUICK 4 PLUS STANDARD CHAMBER AS SHOWN (26' x 12' x 8" EFFECTIVE DEPTH) SIDE AREA: NA (0.74) = NA GAUDAY BOTTOM AREA: 4' x 24 UNITS x 4.7 = 451 SF (0.74) = 334 GAUDAY CAPACITY = 334 GAUDAY SEPTIC SYSTEM SECTION 99.97 COVE 11 OF Fit TOP OF -,K FOUNDATION v a 97(EXISTING) .55 ELEV. 1000 GAL SEPTIC TANK TEE SIZES: (TO BE CONFIRMED) INLET: 6" UP 13" DOWN OUTLET: 6" OP, 14" DOWN REQUIRED VARIANCES FROM TITLE FIVE: 1. SECTION 15.212: LEACH AREA TO BE LESS THAN V ABOVE GROUND WATER (VARIANCE OF 0.84'). porch 2. SECTION 15.211 (1): LEACH AREA TO BE LESS THAN 10' FROM LOT LINE (VARIANCE OF 4'). KITCHEN LIVING ROOM BENCHMARK AT MAG NAIL ELEVATION = 99.43 open to below BED ROOM 2nd FLOOR EXISTING FLOOR PLAN Permit � _`i-0 for RIF- A Ild -ojf St 1' l IC_ Sl C I n_M ONQ Y; & C tO.State and I tea) septic %ariamces. Board of 1'ealth review and alll�ru�:al is leyuire. Iur any fut, c additions/rent v-ationst'Ilterations to sewage fit( lilies -and/or structuveshl-111119. pritiouth I1eall1t Pep" �tnrcnt 1/8" per ft 1/8" per ft 3 .EV. 97.0 3 ELEV. ELEV. D-BOX (6" OF STONE UNDER) -GAS BAFFLE AT OUTLET TEE NOTE: 8" INLET IS NOT THE CENTER INLET OF THE ENDCAP INSPECTION PORT i-- ELEV.= 97.06 T MAX. COVER (1' MIN) 96.73 / II I I°I I°I I°I I°I N I°I 1°I I°I I°I I°I I°I M I°I I°I 1°I 1 II 96.06 ELEV. ELEV. e 26' x 12' - - USE 24 INFILTRATOR QUICK 4 PLUS 4.16' STANDARD CAPACITY CHAMBERS AS SHOWN (26' x 12' x 8" EFFECTIVE DEPTH) ADJUSTED GROUND WATER ELEVATION = 91.9� TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 8-23-18 PERCOLATION RATE: < 2 MIN/IN USGS GROUND WATER ADJUSTMENT: WELL: MIW-29, ZONE: B, ADJ. (JULY): 2.1' 11 ADJUSTED GROUND WATER ELEV.= 91.9 1; NOTES: TH-1 O/A HORIZON LOAMY SAND 10YR 5/2 B HORIZON LOAMY SAND 10YR 618 C HORIZON MEDIUM SAND 2.5Y 7/4 GROUND WATER 99.0 ELEV, PERC AT 36" 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TOBE.USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/8" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D-BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3' WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING LEACH AREA (4 INFILTRATORS WITH 2' STONE) IS TO BE PUMPED AND REMOVED WITHIN 5' OF PROPOSED LEACH AREA. 14, D-BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. SITE PLAN LOCATION: 52 SOUTH SEA AVE., UNIT 1, S. YARMOUTH, MA PREPARED FOR: DAVID & EVE RULE DATE: 8-28-18 SCALE: 1" = 20' BASS RIVER ENGINEERING TH6MAS J. McLEiLyAN, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048