Loading...
HomeMy WebLinkAboutEngineered Plans - 20187 SOUTH YARMOUTH RO PD Cg PS �ESSE p PAN -- --_ \ G� N-7-7,25,50"E w v LOT419 w-� AREA=11,500 S.F. W — i l OV _ _ _ BED N - LIV. _ - �1 _ ; v LOT 186 \ N o = BED #61 N W - _ _ KIT. - -1 PUMP, CRUSH, SANDFILL p N� = BATH _ RUCE AND/OR REMOVE AND - B_ED___= _ - PECK \ ABANDON 1000GAL TANK 23.0' 1 PER TITLE 5 ELH23.0 `3 W ' LOT 421 1 \ MAPLE* \ J,��N'DON TM 24 PINE — NCE� LOT 418 LOT 417 SPRUCE 100 •oo GRAPHIC SC LOT 207 Yarmouth Health Department PP VED ame Date LOCUS MAP LOCUS INFORMATION r LF�IV fCG� EF: LY7� 1 IJ TITLE R: 6657/281 PARCEL ID: MAP 77 PAR. 159 ZONING: R-40 IN STATE ZONE II FLOOD ZONE: "X" COMMUNITY PANEL: 25001CO587J DATED:07/16/14 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 61 CAPTAIN BESSE ROAD SOUTH YARMOUTH, MA. PREPARED FOR ANTHONY & SHARON SPIGNESE AUGUST 16, 2018 OF M OF M P��N ASs9c �P�SN A EDWARD y� 02� DB.V1D E. A. S. SURVEY, INC. 141 ROUTE 6A SALT POND BUILDING P.O. BOX 1729 SANDWICH, MA. 02563 ( IN FEET ) I inch = 20 ft. BUS: (508)888-3619 SHEET 1 OF 7 CELL: (508)527-3600 031 r TOP OF EXIST. FOUNDATION EL=24.7 (21.3') (10') MIN. EL=23.0 SWEEP CLEAN U• W/SCREWCAP TO GRADE 21.2' S=.026 20.90 EL=20.32 EXIST. INVERT 4" SCHEDULE 40 P.V.C. -MIN. PITCH 1/4" PER FOOT EL=22.7 RISER 9" MIN. RISER AS COVER AS NEEDED I NEEDED - EL= 21.32 - LI 10 I „) 1MIN. I 14 1 4' GAS !r I BAFFLE COMPACTED SAND PROPOSED H-10 1,500 GALLON TANK GENERAL NOTES 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. ALL ACCESS PORTS OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 3" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 3" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10' OF DRIVES OR PARKING AREAS THEN THEY MUST WITHSTAND H-20 LOADING. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 2% GRADE OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEES SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEANOUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES. 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONTRUCTED OF 4" PVC. 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND FIRST TWO FEET OUT OF THE DISTRIBUTION BOX SHALL BE LEVEL. 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY, INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. 13. LOT IS WITHIN STATE ZONE II CONSTRUCTION NOTES: 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNE11C MARKING TAPE OR A COMPARABLE MEANS. i 4" SCHEDULE 40 P.V.C. MIN. PITCH 1/8" PER FOOT EL= 22.3 6„ MAX.........,,. RISER AS NEEDED LEVEL FOR 2' 5.0' S= .02 --i►1 EL=19.97 I6" SUMP EL= INVERT IN' 6" BASE OF MECHANICALLY COMPACTED SAND PROP. DB3 DISTRIBUTION BOX (H-20) (TYP.) No 34" -so"- TEST PIT RESULTS: PROFILE OF SEWAGE DISPOSAL SYSTEM (NOT TO SCALE) EL= 22.1 EL= 21.1 2 OBSERVATION PORTS W/SCREWCAP TO GRADE p CLEAN SAND FILL hQppQ 24' INVERT PER 310 CMR 15.255 OVER 12» h oJ� EL= 19.72 BETWEEN A O UNITS MIN. OF 6" �p �p EL= 20.11 �p 3. 7vv 8 EL= 19.45 24.0' 24-QUIK 4 (LOW PROFILE) INFILTRATORS (34"W X 48"L X 8"H) EACH SOIL ABSORBTION SYSTEM (S.A.S.) > ci BED FORMATION (11.3' X 24') (21.3X 34' W/STRIPOUT) W 0 CLEAN SAND FILL I I ..J END VIEW SOIL TEST DATE: AUGUST 1, 2018 B.O.H. AGENT: AMY VON HONE SOIL EVALUATOR: EDWARD A. STONE BACKHOE: ELLIS BROS. KEVIN) TH#1 EL.= 21.1 @3611(<3 MR) ELEV. DEPTH (IN.) HORIZON TEXTURE COLOR MOTTLING OTHER 20.4 0"-8" OAE LOAMY SAND 10YR5/1 N/A 17.8 8"-40" B LOAMY SAND 7.5YR6/6 N/A 12.1 1 40"-108" C MEDIUM SAND 2.5Y7/4 N/A GROUNDWATER ® 84" EL=14.1 CD EL= 19.45 JULY MIW29 2018 ZONE B = 2.1 JULY AIW 230/231 2018 ZONE B = 0.4 AVERAGED ADJ.=1.25 15.35 GROUNDWATER @ ELEV.= 14.1 DESIGN DATA: NUMBER OF BEDROOMS ......... GARBAGE DISPOSAL ................. TOTAL ESTIMATED FLOW: (110 GAL./BR./DAY X 3 BR.) 330 330GPD X 200% = 660 GAL NEWLY PROPOSED 1500 GAL. SEPTIC TANK INSTALL: 24 QUIK 4 (LOW PROFILE) INFILTRATORS (34"W X 48"L X 8"H) AND BACKFILL WITH CLEAN SAND FILL PER 310 CMR 15.255 (11.3' X 24') (21.3' X 34' W/STRIPOUT) SOIL CLASSIFICATION ................ DESIGN PERCOLATION RATE.....5� MININ. EFFLUENT LOADING RATE ......... REQUIRED LEACHING CAPACITY.....3_3_0 GA�DAY LEACHING CAPACITY PROVIDED ..... 336_ GA -DAY (4) ROWS OF (6)INFILTRATORS X 4.73 S.F./L.F. 96 L.F. X 4.73 S.F./L.F.= 454 S.F. 454 S.F. X .74 GPD./S.F.= 336 GPD 336 GPD PROVIDED - 330 GPD REQUIRED = 6 GPD RESERVE °F M4 Ss9c9 IF MASsgcti SEPTIC SYSTEM DETAIL PAGE o� EDWARD �s a2 DAVID s #61 CAPTAIN BESSE ROAD A. D. STONE y F AHE T J. N SOUTH YARMOUTH, MA. 0'2 � �o ► NO.AUGUST 16, 2018 SHEET 2 OF 2 J# 2031