BLD-19-2154
1? F VECTOR F -+ 7 EnO1nEER3 10/8� Der evc6 J Project Number: U2041-1881-182 \�\kT\J December 6,2018 Trinity Solar 20 Patterson Brook Road,Unit ill W.Wareham,MA 02576 ATTENTION: Ashley Grey REFERENCE: Robert Rynning Residence: 10 Bradford Road,Yarmouth,MA 02673 Solar Panel Post Installation Letter Dear Ms.Grey: Per your request,we have reviewed photographs and a post-installation checklist for the above-referenced site. Based upon our review, it is our conclusion that the installation of solar panels on this existing roof occurred in accordance with the building code and our original requirements as stated in a letter dated October 10,2018. Rafter size and spacing has been verified to match the original design. Water damage was not encountered during work on and under the existing roof. No pre-installation splits,cuts,breaks,or visible sagging was encountered in the existing roof framing. After installation was complete, it was verified that all roof-penetrating fasteners actually penetrated into the roof framing and did not visibly split the framing members. No existing damage to any existing structure was discovered and no damage was caused to any existing structure during installation, according to the installer. All roof penetrations were sealed and flashed as a means of waterproofing. Our conclusions are based upon our review of the photos and a checklist prepared by the installer. This letter does not waive the installer of any responsibility for improper installation. As stated in a previous letter, our conclusion regarding the adequacy of the existing roof is based on the assumption that all structural roof components and other supporting elements are in good condition. We hope this meets your needs. If you have any further questions regarding this matter, please call this office at your convenience. Very truly yours, VECTOR STRUCTURAL ENGINEERING,LLC E*OF., M�,ELLS L 4.0Digitally signed 1 STRUCTURAL L 'A., Wells by Date: Holmes Holm,es2A t x r 15:2U1815912 -07600' slow, ° Wells Holmes,S.E. MA License:54240—Expires:06/30/2020 Project Engineer WLH/ash 651 W. Galena Park Blvd., Ste. 101 /Draper, UT 84020/T (801)990-1775/F (801) 990-1776/ www.vectorse.com i. 01eY TOWN OF YARMOUTH Building Department V�� BUILDING Q��° _ 4i• (508)398-2231 ext.1261 _A(1,t \1 ttG:i .. . _C Q \D! PERMIT PERMIT NO ;BLD-19-002154 ?�:;� ;s' y ISSUE DATE :10/29/2018 JOB WEATHER CARD APPLICANT Trinity Heating and Air DBA Trin PERMIT TO : Repair AT(LOCATION) 110 BRADFORD RD,WEST YARMOUTH,MA 02673 I ZONING DISTRICT I I Bldg.Type: !Residential SUBDIVISION MAP BLOCK LOT 029.205 BUILDING IS TO BE: CONST TYPE USE GROUP REMARKS Install 3.54kw solar panels on roof.Will not exceed roof panel,but will add 6" CONTRACTOR to roof height.12 total panels. LICENSE IMA !Construction Supervisor Trinity Heating and Air DBA Trinity Solar AREA(SQ FT) 1227,688,1261 EST COST($) 15000.00 PERMIT FEE($) 150.00 Tristan Souza M� 20 Patterson Brook Rd Unit 1 OWNER !PATCH RONALD D BUILDING D BY W Wareham,MA 02576 ADDRESS PATCH CORNELIA M,2 RODNEY TER [NORTHBOROUGH IMA 01532.1931 ✓�/.r PHONE THIS PERMIT CONVEYS NO RIGHT TO OCCUPY ANY STREET, ALLEY OR SIDEWALK OR ANY PART THEREOF, EITHER TEMPORARILY OR PERMANENTLY. ENCROACHMENTS ON PUBLIC PROPERTY, NOT SPECIFICALLY PERMITTED UNDER THE BUILDING CODE, MUST BE APPROVED BY THE JURISDICTION. STREET OR ALLEY GRADES AS WELL AS DEPTH AND LOCATION OF PUBLIC SEWERS MAY BE OBTAINED FROM THE DEPARTMENT OF PUBLIC WORKS.THE ISSUANCE OF THIS PERMIT DOES NOT RELEASE THE APPLICANT FROM MINIMUM INSPECTIONS REQUIRED FOR ALL APPROVED PLANS MUST BE RETAINED ON WHERE APPLICABLE SEPARATE CONSTRUCTION WORK: 1)FOUNDATIONS OR JOB AND THIS CARD KEPT POSTED UNTIL PERMITS ARE REQUIRED FOR FOOTINGS.2)PRIOR TO COVERING STRUCTURAL FINAL INSPECTION HAS BEEN MADE.WHERE ELECTRICAL PLUMBING/GAS MEMBERS(READY FOR LATH OR FINISH COVERING) A CERTIFICATE OF OCCUPANCY IS AND MECHANICAL 3)FINAL INSPECTION BEFORE OCCUPANCY 4) REQUIRED,SUCH BUILDING SHALL NOT BE INSTALLATIONS. REFER TO DETAILED INSPECTION SCHEDULE OCCUPIED UNTIL FINAL INSPECTION HAS BEEN MADE. POST THIS CARD SO IT IS VISIBLE FROM STREET BUILDING INSPECTIONS APPROVALS OTHER: I WORK SHALL NOT PROCEED PERMIT WILL BECOME NULL AND VOID IF INPSECTIONS INDICATED ON THIS CARD UNTIL THE INSPECTOR HAS CONSTRUCTION WORK IS NOT STARTED WITHIN SIX CAN BE ARRANGED FOR BY TELEPHONE APPROVED THE VARIOUS MONTHS OF DATE THE PERMIT IS ISSUED AS NOTED OR WRITTEN NOTIFICATION. STAGES OF CONSTRUCTION ARM/F • SOLAR HOMEOWNERS AUTHORIZATION FORM 1, Robert Rynning (print name) am the owner of the property located at address: 10 Bradford Rd (print address) I hereby authorize Trinity Solar, and their subcontracting company , to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System located on my Property. This authorization includes the transfer/re-administering, and/or cancellation of any existing permits on file for the purpose of updating/applying with an alternate subcontractor. Customer Signature.. Date: 9/30/1 8 Print Name: Robert Rynning Commonwealth of Massachusetts IkeDivision of Professional Licensure Board of Building Regulations and Standards Constr rtddpgrvisor CS-088720 >q ' „ Wires 04/10/2020 �4 ,0, �, • S m�{. riftt PAUL A EATON ' , 'gip 7 MARBLE Sc APT.310E k `%' �' r _ Ir 1/4 '" WHITMAN MA 023 n,nt,,sl'„ S ` #'. _ 10.00- Commissioner re to possess a current edition of the Massae Building Code is cause,for revocation of this Call(617)727-3200 inlorti o ab ut this license` it www.mass.gov/d lb e''ad&d Rd Office of Consumer Affairs and Business Regulation • • One Ashburton Place- Suite 1301 Boston, Massachusetts 02108 Home Improvement.Cbptractor Registration I- Type: Supplement Card TRINITYHEATINO&AIR,INC. V ,i 2-( Registration: 170358 D/B/A TRINITY SOLAR " ' ' ! Piration: tOJ11p10t9 20 PATTERSON BROOK ROAD UNIT 10 t 'r o} WEST WAREHAM,MA 02576 `A t tiiiii I ! Sckon ""11 t It-µ Y �ti i uplift Sates and Return Card. SCA 1 0 20M-own op cz) Office of Consumer,lube a Business Regulation HOME IMPROyEMENT CONTRACTOR Reglatration valid for Individual use only TYPE;Suoolement Card before the expiration date. H found return to: 8001strattonExuiratlon Office of Consumer Affairs and Business Regulation .- €179151 I..,� 10/112019 10 Park Plaza•Suite 5170 TRINITY HEATING if.AI 1NC.-° Boston,MA 02116 D/B/A TRINITK,SO J t' PAUL EATON Y t'"-*-I 11' ,C{Cue--• j/////� ��A WA SON ,MA,BROOK UNIT 10 •- `Not valid without signature WEST WAREHAM AM 02576 Undersecretary • The Commonwealth of Massachusetts _ =�l Department oflndustrialAccidents =111.del; 1Congress Street,Suite 100 %Wig e Boston,MA 02114-2017 www mass.gov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name(Business/Organization/Individual): Trinity Heating&Air DBA Trinity Solar Address: 2211 Allenwood Rd. City/State/Zip: Wall,NJ o7719 Phone#: (732)7804779 Are you an employer?Check the appropriate box: Type of project(required): i.1211 am a employer with 300 employees(MI and/or part-time).* 7. 0 New construction 2.0 I am a sole proprietor or partnership and have no employees working for me in 8. ❑Remodeling any capacity.[No workers'comp.insurance required.] 3.0 I am a homeowner doing all work myself.[No workers'comp.insurance required.]t 9. ❑Demolition 4.0 I am a homeowner and will be hiring contractors to conduct all work on my property. I will 10 El Building addition ensure that all contractors either have workers'compensation insurance or am sole 11.[ 'Electrical repairs or additions proprietors with no employees, 12.0 Plumbing repairs or additions 5171 1 am a general contractor and I have hired the sub-contractors listed on the attached sheet. ]3.❑ROOF repairs These sub-contractors have employees and have workers'comp.insurance? 6.0 We are a corporation and its officers have exercised their right of exemption per MGL c. 14.0 Other 152,§1(4),and we have no employees.[No workers'comp.insurance required.] 'Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. 1 am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: HDI-Global Insurance Company Policy#or Self-ins.Lic.#: EWGCR000065617 Expiration Date: 11/1/2018 Job Site Address: City/State/Zip: Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. do hereby certify under the pains and penalties of perjury that the information provided above is true and correct - Signature: Date: Phone#: (508)291-0007 Official use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: S ACROCERTIFICATE OF LIABILITY INSURANCE 1��� 1DNyYY) 1207 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER CONTACT Arthur J.Gallagher Risk Management Services, Inc. v ONE FAX 4000 Midlantic Drive Suite 200 _(AIC No Fr) 856 482-9900 IA/c Npl:856482-1888 Mount Laurel NJ 08054 no RIES. INSURER(S)AFFORDING COVERAGE NAIC 0 INSURER A:HDI-Global Insurance Company 41343 INSURED TRINHEA-03 INSURER B:Liberty Insurance Underwriters Inc 19917 Trinity Heating&Air, Inc. INSURER C: 28 Patterson Rd INSURER D Wareham,MA 02571 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: 1553770879 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. . INSR TYPE OF INSURANCE ADDL:SUHR1 POLICY EFF POLICY EXP INSD'WND' POLICY NUMBER (MMIDDIYYYY) IMMIDDNYYY ' LIMITS A X COMMERCIAL GENERAL LIABIUTY EGGCR000065617 11/1/2017 11/1/2018 EACH OCCURRENCE $2,000,000 _ CLAIMS-MADE n OCCUR DAMAGE TORENTED PREMISES occurrence) 5500,000 MED EXP(Any one person) $0 PERSONAL&ADV INJURY _ $2,000,000 GENL AGGREGATE LIMIT APPLIES PER: - GENERAL AGGREGATE _ $2,000,000 POLICY X )ECT 1 LOC PRODUCTS-COMP/OP AGO $2,000,000 OTHER: $ A AUTOMOBILELIABILITYCOM&NEDSINGLE UNIT EAGCR000065617 11/1/2017 11/1/2018 (Ea acddem) $2,000,000 X ANY AUTO BODILY INJURY(Per person) $ OWNED AUTOS ONLY AUTOSULED BODILY INJURY(Per accident) $ HIRED — NON-OWNED PROPERTY DAMAGE AUTOS ONLY _ AUTOS ONLY (Per accident) $ —$ B UMBRELLALIAB X OCCUR 11000231834-02 11/1/2017 11/1/2018 EACH OCCURRENCE $3,000,000 A X EXCESS LIAR EXAGR000065617 11/1/2017 11/1/2018 - CLAIMS-MADE AGGREGATE $3,000,000 _ DED RETENTIONS - Limit Of$3,000,000 s2l,000,000 A WORKERS COMPENSATION EWGCR000065617 11/12017 11/1/2018PER 0TH- AND EMPLOYERS LIABILITY YINRIX STATUTE ER ANY PROPRIETOPARTNEWEXECUTIVE ❑ N/A E.L.EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE•EA EMPLOYEE $1.000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 A Automobile EAGCR000065717 11/1/2017 11/12018 All Other Units $1,000/$1,000 Comp/Collusion Ded. Truck-Tractors and Semi-Trailers $5,000/$5,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Named Insured includes Trinity Heating&Air, Inc and BPTP Future Holdings LLC Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Trinity Heating&Air,Inc THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 20 Patterson Brook Road ACCORDANCE WITH THE POLICY PROVISIONS. Wareham MA 02571 • AUTHORIZED REPRESENTATIVE 1 I . ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD VECTCR E n s l n E E R s VSE Project Number:U2041-1881-181 October 10,2018 Trinity Solar ATTENTION:Ashley Grey 20 Patterson Brook Road,Unit#1 W.Wareham,MA 02576 REFERENCE: Robert Rynning Residence: 10 Bradford Road,Yarmouth,MA 02673 Solar Array Installation To Whom It May Concern: Per your request, we have reviewed the existing structure at the above referenced site. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on the panel layout plan. Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. Design Parameters Code:Massachusetts State Building Code(780 CMR Chapter 16,9th Edition(2015 IBC)) Risk Category:II Design wind speed: 140 mph (3-sec gust)per ASCE 7-10 Wind exposure category:C Ground snow load: 30 psf Existing Roof Structure Roof structure:2x6 rafters @ 21"O.C. Roofing material:asphalt shingles Connection to Roof Mounting connection:(1)5/16"lag screw w/min.2.5"embedment into framing at max.63"O.C.along rails Conclusions Based upon our review,we conclude that the existing structure is adequate to support the proposed solar panel installation. The glass surface of the solar panels allows for a lower slope factor per ASCE 7,resulting in reduced design snow load on the panels. The member forces in the area of the solar panels are not increased by more than 5%;thus, the stresses of the structural elements are not increased by more than 5%.Therefore,the requirements of Section 807.4 of the 2015 IEBC as referenced in 780 CMR Chapter 34,9th Edition are met and the structure is permitted to remain unaltered. The solar array will be flush-mounted (no more than 6" above the roof surface) and parallel to the roof surface. Thus, we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind (uplift), the governing load case. 651 W.Galena Park Blvd.,Ste.101/Draper,UT 84020/T(801)990-1775/F(801)990-1776/www.vectorse.com VSE Project Number: U2041-1881-181 • VECTOR Robert Rynning Residence 10/10/2018 E n G I n E E R S Limitations Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. The contractor shall notify Vector Structural Engineering,LLC should any damage,deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found. Connections to existing roof framing must be staggered, except at array ends, so as not to overload any existing structural member. The use of solar panel support span tables provided by • others is allowed only where the building type,site conditions, site-specific design parameters, and solar panel configuration match the description of the span tables.The design of the solar panel racking(mounts,rails,etc.),and electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Vector Structural Engineering assumes no responsibility for improper installation of the solar array. VECTOR STRUCTURAL ENGINEERING,LLC 1 "- 'ROGER T. %,, ALWORTN 1' ...3i CIVIL i t No.47740 y ' q is '�,i 'SIGNAL 6 Roger Alworth,P.E. MA License:47740-Expires:06/30/2020 • Principal Enclosures RTA/egg 651 W.Galena Park Blvd.,Ste. 101/Draper,UT 84020/T(801)990-1775/F(801)990-1776/www.vectorse.com DocuSign Envelope ID:9821A4FE-55868-48C5-9B41-8830B35A940A • S U n n nG • Sunnova Easy Save Approximate Start Date.The installation work to be possible, but in no event more than twelve(12) performed by Contractor pursuant to this Lease shall months from the Commencement Date,subject to commence within three(3)days from the date that is any applicable amendments. The time between the later of the date in which(a)all permits have been Commencement Date and Interconnection Date will issued; (b)any homeowner's association approval vary depending on a number of factors,some outside letter has been received; and(c)all materials have the control of Contractor.These factors include the been delivered to the site(the"Commencement process for obtaining utility approval for net metering Date"). and interconnection of your System.The project shall Approximate Interconnection Date.All work to be deemed completed upon the date the System is install the System shall be completed as soon as connected to the electrical grid, and begins generating power(the"Interconnection Date"). 3. SYSTEM DESCRIPTION Solar System (DC) 3.540 kW Modules Q-Cells Inverter SolarEdge `u Monitor SolarEdge 1 Year Production(Estimated) 5,087.86 kWh Usage Offset Percentage , 113.28% Your panels may be from any Sunnova-approved manufacturer(including, but not limited to, Boviet,Canadian Solar,Q- Cell(Hanwha),Trina,Telesun, Boviet, Seraphim, LG Electronics, SolarWorld,Centro, Eco, Silfab and RECOM). Sunnova may need to substitute equipment depending upon availability and may need to change its list of approved manufacturers from time to time. Should the substitution of manufacturer materially change the production or cost of the System,either party may exercise the options available in Section 6(b)below.Absent such material change, your Installer will inform you through the online portal MySunnova or in writing of your panel manufacturer. YOU AGREE THAT YOU+FAW3IaEEVIEW ED THE ABOVE DESCRIPTION OF THE SYSTEM AND EQUIPMENT. Vort .Homeowner's Signature: 1� ' 1 a -211BDDO7D2FE488.. Co-Homeowner's Signature: 20 East Greenway Plaza Ste 475,Houston,TX 77046 Date:9/29/2018 281.985.9900 wwwsunnova.com ®2018 Sunnova Energy Corporation.All Rights Reserved. 2 Contract ID:HA002022956 DocuSign Envelope ID:9821A4FE-5868-48C5-9641-8830B35A940A • Su n nnVa� Sunnova Easy Save rzzi 4. LEASE PAYMENTS; AMOUNTS A. Amounts Due at Lease B. Monthly Payments: C. Other Charges(not D. Total of Payments(the Signing or Delivery: Your first Monthly part of your monthly amount you will have $0.00 Payment(which includes payment): paid at the end of the estimated sales tax, if Estimated taxes other Lease): applicable)of$65.88 is than sales taxes $26,469.96 due on the first Payment collected monthly(if Date. During contract applicable)$0.00 validation, you will choose one of the available payment date options for your Payment Date.After your first Monthly Payment, 299 additional Monthly Payments will be due on the same day of each following month. Please refer to Schedule A for the amounts of these payments. The total of your monthly payments (including estimated sales tax, if applicable)is $26,469.96. E. Purchase Option at End of Lease Term: F. Other Important Terms: You do not have an option to purchase the System at See below for additional information on early maintenance the end of the Lease Term. responsibilities,warranties, late and default charges, insurance,and any security interests, if applicable. NOTE: Monthly payment amounts above do not reflect discount for making automatic ACH payments. See Section 5(e)and Schedule A for additional information. Payments due upon installation are due immediately prior to commencement of installation. Monthly payment amounts include estimated taxes based upon current available tax rates as provided by a third-party service and are subject to change based upon local and state taxing rate changes. YOU AGREE THAT YOU HAVE REVIEWED THE ABOVE TERMS INCLUDING THE PURCHASE PRICE AND MONTHLY PAYMENTC D JL °Y` ant Homeowner's Signature: `` l 211BDDOID2FE468..: Co-Homeowners Signature: 20 East Greenway Plaza Ste 475,Houston,TX 77046 Date:9/29/2018 281.985.9900 ww.v.sunnova.com C 2018 Sunnova Energy Corporation.All Rights Reserved. 3 Contract ID:HA002022956 DocuSign Envelope ID:9821A4FE-5868.48C5-9B41.8830B35A940A un n nva w Sunnova Easy Save ,., HOMEOWNER Daryl Rynning DATE ISSUED 9/17/2018 11:30 AM ADDRESS 10 Bradford Road INSTALLATION 10 Bradford Road West Yarmouth, MA 02673-4606 LOCATION West Yarmouth, MA 02673-4606 $0.00 $50.8825 Years Upfront costs Monthly payment-Year One Agreement term (Includes ACH discount -_ and estimated taxes) 'It 4 ► ;tom ► { • Trinity Solar and Sunnova will install a 3.540-kWh solar • You may renew this agreement for up to two successive five- system on your home.(Sec.3) year terms at the end of the original 25-year term.(Sec. 11) • Your system is estimated to produce 5,088 kilowatt • If you sell your house,you may transfer the agreement and hours in the first year of service.(Sec.3) warranties to the new homeowner, provided that the new • Your agreement includes your down payment of$0.00. homeowner meets Sunnova's credit requirements.(Sec.12) (Sec.4) • If you choose not to renew the agreement at the end of your • Your monthly payment will never increase by more than 25-year term, Sunnova will remove the system at no cost to approximately 2.9%per year.(Schedule A) you.Conditions apply. (Sec.17) • Trinity Solar will complete the design and engineering - This agreement requires the parties to resolve their disputes drawings for your system,and Sunnova will review the by arbitration rather than by lawsuits in court;jury trials and final design to ensure it meets our high quality _ class actions are not permitted(Sec.19) standards.(Sec 6(b)) • Your agreement gives you a 7-day cancellation period • Your system activation may experience delays as a result without incurring any fees.of the process for obtaining the necessary building permits • Any savings estimate is dependent on the energy usage and utility approval for net metering and interconnection of information you provided us,and may change as your usage your system.Once your system is installed,it must still and utility rates change over time. pass utility inspection before you can turn it on. • Your solar system is covered by the Limited Warranty for • You will receive a$15.00 discount each month when you the term of the agreement.(Exhibit 2) set up automatic payments from your checking or savings account(pricing above already reflects discount).(Sec. • Once you receive your first Sunnova bill,you will be receiving 5(e)) two monthly electricity bills:one from Cambridge Electric Light-NSTAR Electric and one from Sunnova. • Your estimated monthly taxes are$0.00 in the first year of • When the electric grid goes down,your solar power system service,in addition to your Sunnova monthly payment (pricing above already reflects discount).Estimated taxes will not work. (Exhibit 2) may vary. I have reviewed, understand and agree with the above agreement terms and process. The pricing provided in this Easy Save Agreement is valid until October 16,2018 Ho nnNiers Initials Homeowner's initials 11tl 0 2018 Sunnova Energy Corporation.All Rights Reserved. Agreement ID: HA0D2022956 DocuSign Envelope ID:9821A4FE-5868-48C5-9841-8830B35A940A • , SU n n nvaM Sunnova Easy Save Homeowner Name and Co-Homeowner Installation Location Installer/Contractor IAddress Name (If Any) 10 Bradford Road West Trinity Solar Daryl Rynning I Yarmouth, MA 02673-4606 2211 Allenwood Rd 10 Bradford Road Wall, New Jersey 07719 ! West Yarmouth,MA 02673 License Contract ID CT:0635520; ELC.0124054-E1 ( HA002022956 DE:2066600876; T1-0005929 MA 170355;21233A I MD: 109285; 11834 I NJ: 13VH01244300; Electrical I Business Permit# 34E601547400 I NY: 52821-H; 11.2409780100; L004203IPA: PA128551 ( RI:39372 � I David Dillon Sunnova License ISunnova MA 184093 1. INTRODUCTION This Lease is a legally binding agreement,so This solar lease (this"Lease') is the agreement please read everything carefully including all of between you and Sunnova Energy Corporation the exhibits. (together with its successors and assigns, "Sunnova" This Lease requires the parties to resolve their or"we"), covering the lease to you of the solar panel disputes by arbitration rather than by lawsuits in court; system (the"System")described below. The System jury trials and class actions are not permitted. will be installed by the Installer listed above at the If you do not meet your contract obligations under this address you listed above.This Lease will refer to Lease,you may lose your rights to the System. this address as the"Property"or your"Home."This Lease is up to eleven (11) pages long and has up to If you have any questions regarding this Lease, three(3) Exhibits depending on the state where you please ask your sales consultant. live. This Lease has disclosures required by the 2. LEASE TERM Federal Consumer Leasing Act and,where applicable, state law. Sunnova provides you with a Sunnova agrees to lease you the System for 25 years Performance Guaranty and Limited Warranty(the (300-full calendar months),plus, if the "Limited Warranty").The Limited Warranty is Interconnection Date is not on the first day of a attached as EXHIBIT 2. Sunnova will also provide calendar month,the number of days left in that partial you with a System user manual entitled"Solar calendar month, including the Interconnection Date, Service Guide" (the"Guide")that contains important as defined below.We refer to this period of time as operation, maintenance and service information. the"Lease Term."The Lease Term begins on the Following the execution of this Lease,a Interconnection Date. Sunnova will notify you by representative of Sunnova will contact you to verify email when your System is ready to be tumed on. your information(the"Validation Call"). 20 East Greenway Plaza Ste 475,Houston,TX 77046 Date:9/29/2018 281.985.9900 www.sunnova.com 1102018 Sunnova Energy Corporation.All Rights Reserved. 1 Contract ID:HA002022956 U2041 81-181 JOB NO.: SOLA 18 SUBJECT: SOLAR LAYOUT E fl 0 1 F1 E E R S PROJECT: Robert Rynning Residence BACK m AC ■DC ® rr Ct '� C C r � e 5E UD e-C I C,f p = t E''RFEEEEP ,� — ` EE E e er t _ r f r C M EP r,--t rl L E ,r 4,..' t I-r t :i µ ) fr` "LEE,: r ` rtzEi LEI E C E t r rte�C t` Cts [.-i tre 6 rL r F .f r rcj �W t .M.. . . 7.717-;7E4- ErE .;a FRONT 7 ERNEEI LAWS/MoR. N ARRAY exwr WARM NOTE LI MIMEO NRRNLN ASSUMES ALL NFYEOMMY FOR DETERMINING MITE 0aTY6 APED E RVIIK RUNLATIEE MMmIpN01ME ]EMYARMYMMCEIIE]MOI [DTO111OW5 M1 OK SW 12.295W MODULES a/ITEM EDGE MORE MEIN" E.IEOWFR MICRO AMBIENT TEMPERATURE R.1WWI . / ....... '1•\ AWN MINIMUM MEAN 12R1ME MY 0E6 ISEMDEVRImEF1x YEIF1.lMWp •ti• HEEMTIIRF NR AWE LOCATION MOST SOMA,TO _.__. O. ............. ..__. BINUIION LOCATION.LOWEST EMECRDMMENT - NNM15 -- - _ ---...3---=4.33-43.3-3..p. y~ ]EY •TRYIMRD INTOE MINTER I DEM OIC RI 4RATIOAEM•HEST MONTH %DDAYF MOST MlIE YED - 4 RATURE FOR ASHRAE LOCATION SWIM TO INIYBAITNLIXATIIM.MOTES!CONTINUOUS TEMP• I! (. . ITSNYMN41 DOAl MOS 44 EXCEED OTC x TEUNITED I: `\ / SEATO MVxra4 N ,CA 5 .I2R w FOC TESSTNI - -- cxE.CTIvsISACM opwpulD • Ir Issued/RM4® MOW EV MOUSING Mt OUTDOOR LDSMM IESI W F E ATC OR LESS PUDEUNITED STATES, - s.l Ft STSIFM CEMNS INSTALLED ON OR N MoNG1 51•1101•0171•RNID LNIDOWIF REACTION THAT Cox Molt PECAN CONOKIESIN NCOMNx1 Mm Ir . ................... mkt 4D1.20.1 DRAY.W1 . I:: IMO_ OESEIMMN DATE t)MLOTWE4C UM WASTEMS LMLL DECIMATEDTO OPERATE VAIN _ !CARR MO GHRH CRAW ASBEREC SIDED 191010VOL SAL LAN4 NC i', Nord TNe:_ RYNNING,ROBERT- IMODMINmEIICCDIXIXUICOMTIESLWIE TINir AaTB'.gUAND]A IDENTIFIED WITH TH1 FOLLOWING OUTER Ii EGAlRTIT COTHOu?IXS•NBKy Lg NN1RN1 i1I Pm4R:I MJm_R:_ WIAWAY NN 1u NPAI CE OMMI6 91.641 E EAR EXITING [mFExW ICI[EUIRwrt ANT sxNlE U]lMW SO INSI GRADEBDE ITLWSS �I 10 BRADFORD RD IROTECIED T CONDUIT VMM EXPOSED TO DOW,' MYIn ALDER �VIDAMNNMEANE suxmmit MN ARRAY°WOWl LONGERTWMN N'UWE 1'PNMrsME wl NVrt TEN WEST YARMOUTH,MA 02673 NOM EDGE RE RWNOIDIODMO N SIM SAC0Y1RM CARYNICNL SMALL NC •O A166333&-70.353115 MFFODSFOA DIRECT SUNTIOIH SNNI CONIDIAL �- 14CURRENT4NM1WGCECUCIpIi r '� DSNAIIy TINS: RI4L WMEISx4U15NWlEU4T1YMLV MUM 11 ' II - OHERWNFNOIED rl —I NiOI- -1 WI n[NN oEEENISMuwOlETtLACE .y^ M D PROPOSED PV SOLAR SYSTEM ROCATOP SMALL E WROTO IY E USED -^ f 0 CONNECTED LCTFUDIT80�FYURAY 11W ORAYNCE 9U4CE ' r"" I'D O/0—2.0OUTDOORS wvERTER II Drawing OOWxR.I I, I IE E IE POINT E COINECTTON NEC I GGII�� 70531 UJ WIPE TWO MIKES RNA MRSOM ONE A U ,NI-J ming, AA y(j- y, ulunAYMmERANINVERTER...DNIUHO r___ IJ -I ___ _ _ B tl •1� I,C TI 0 0 �„�2 ; SnEm MI=maim MEMENSILWI M LDCATN EBovIE ECO.Ulan iNN -- // 54333 ! W NDTwMDNE1D] - . ]].IYl1OMRA[MIdORI{UFMIONMNNED, E MANE ED L--SQUARED J , mY GAON EEMTION CIRCUITS-MID NO UNUSED POSITION OR 3pE Ma{FEDTEMFE M3IR0 �, ____Jr0"4•00011 QOM: 17 LOWS NEC 7•3.1.2111) 14.IALL EQUIPMENT NMMUD MONM3WLMSf MmRCfRI• DIFA[6R4.TnF A NOMMMUNG warn commiry meow:, EKmACT W GUOIIITECSFOR OMENE EE NNE CONDIXT010 UNTM:RE a 27•0111 RONALD CONDUCTOR WOODY RA STRODE DEAL SUANOVA 1014•030011/1:11300113511.111.7M M MOQUE SPECIFICATIONS • RIO,T :10 MWADry H5IDRMM A GL.I2951 YANKRACEWAIXMTTNG•TEMC DM HUM SE DAR ISM AT, W aLCIO-SMS u.Mn u win. {IilTl 1351:".13 xti.xlU�N.lal+rlDA R No. Sheet wwLn NAM!1Eh4 HEEEgE ONE 105 VMD x - A 4 Hw1CCC Tenn.%Mine M P1 PV - 3 ACTOW REIMNCEgNTEI MIADN R T/ WE WW/I%EIINW3 DEWHWWLIlDNIIMWI moue 1250.031.IS.BM O W NYAT E]+R l xxx L 1 Bu HRAaI NR4 W 0 Al!MEG TEMP: DCO 0 W NYE WI]O0 HRa31M TMNWI NOMA. W MID Aa HMPD'CRACTTY IA i SEs{ •• MtW.YEMINI4•,CCGNAVCCmn R/]EMTLM-LIEnOw4EOEINTxxa3EHL.J.0 n I ty D,•ID BOA ID IM N^• 1 ODSBMM/STHEREFORE M WE MIS VALID ¢ I N4Nwin NB AEW/n MOL CWRRTeY TS inn 40 OCPOrnin 15 625 SOLAR CALCULAITON T OVEM,NRM EDRUTE.' _ 1014 IMSRI ER CURRENT:1350A M IS nom lD aA1• •I.IS4 15 AM ERYNMM PROTECTION VAD un MNNNEMr DTA 7•41. 4NWWnnomN ....I,SE.m-,. • I, INSTALLATION OF NEW BRApFOftpRp• ROOF MOUNTED PV SOLAR SYSTEM t--5-.0-,-,7-4, w � � i I ; `�, � ;nY N �`•+; 10 BRADFORD RD "� `tt� �5 '' n WEST YARMOUTH MA 02673 /. Se ,` �°I,.,`T s icli 11 E rr*E"!C[ T �^ "• Issued/RIIYoas "y[i VICINITYMAP SITE NO �GE:aE.N. Mn SCALE:NTS ROSS Tey. RYNNING,ROBERT- MOM nmcnMa.EwsE0 Protect Address: 10 BRADFORO RO WEST YARMOUTH,MA 02673 41.652235.-10.253145 GENERAL MOTES GENERAL MOTES canna GE4554.NOTES opN„Mm SHEET INDEX T.TIENAYIAIOMCdTP.RORm e. TME mYatweEMM .MEue 1a "CononIPMW PREVAIL". A eCOA[UARINa PV-1 COVER SHEET WI SITE INFO&NOTES Drawing Tey _ Raman.1.3corn.RT FImo STANDAR..^roEENSOSETS WA �.YOLTAI. m PV-2 ROOF PLAN W/MODULE LOCATIONS PROPOSED Pe SOAR SYSTEM FECOPORDED RE THE MA Mie RAO n e M INVERTER glad. 1 Tu�EEev err. ocean row „OM. VADMORG E yE1OPALAteA AGENCY .Me Lam PV-3 ELECTRICAL 3 LINE DIAGRAM S TE ERT rSCE corm CCTOi PHOTOVOLTAIC SYSTEM WARNED AE.Rwr.THIS AEI re REMIT "® WAMMao emmN°aal AP APPENDIX Drawing RnoTrENERI EOOw°0N5ENrMEwow:oN4ALL NJ. ESERENEED*TERNEYYOEAEA TEYAGE saCIE lmi,Mann Ain Re w RNCROfre. n •a0 MMELmaaY roil DIRFcnormamatEC. aurum A.PNn es or av2oALLµ m.soA.LAS MTS wnTEo vR NE TWM. 1. coma • E an.[LMcan s CCEETN .wonmuawL •C aYeEen PORI caxerNlnlal EcrMTea NEC onnordAL aecrmrraCOLE 1,4oTMNEM!NEWERMM THE w.Tn A7i..ELECTRICAL COOS TS NOT IN WAWA 1RCt COMPONENT noeuATTEmr15*maraca PACt1 ens,m. SYSmm Informatory14.• S sent canm.Twrd,I®rwuam®m wax PMTOvCrT NYSTEMTIL11 HE AW AMPERE MRE ov nrMroamMENT tmnCTICM .0 woo.T WMtOES N TIE n INSTALLATIONaSYSTEM toLL 'antiµR RIGEMTMi am6ln P. w Rona_ ma Hatt ran 12 rm.m® AnBAAPGEEBTMm9MEETNOAi. 0 PHARE THE SYSTEM�WW�B.GETy RdE PROCEDURES.wE RENEW(a.EEEne.v 4517 MO ne.o�� RT•YNncraomEmar a�aLL�a POWER aM ITEO TTIEE nle IMTM� Ee AM coosawnon T PWA TO TIE SYSTEM M S,r UP T1! AEG ABOW O ME at MGM OAL MET'EOM. EUNONR T MC AMERICAN NAE SAUCE RC SOC DALY.rmnena roan ACV Ao IEmn [CMCcormaronMN mato ATE.OEA O« ASEETrylEwouLru rl�iMw c carulr lcEoaenwaE Eau NE umv atm-MOOR m.o nausea m Name R1C[w.T,PAC5 AL Ram EWToaXlm EMTRe R11ALN CO fl SEwur.Hc w oaks moan E FOR Y.ET..R m nWaEIE_®THAT TL EOL TTI PROERW.Nnww.E MO 0 a1MaMe0 RR 5119!OTI EB ATT0 NWrSTALn1ON CREOMNAYSINT/A FOArox OF HO*Nana SWEAR TO a TMESI'A WOWING THE CATMT LIION MNAU*L pNEE MITRE Cum OCHER iEaIMMER NET EANIITOE�AER REM.NO. Sheet T�OGE�EEMOTMLGEWscApi a BETHE WANED 1 TIE LOCATENO PROPOSED B C DIRECT CURRENT IT2 war a pce �� MM . am P1 PV -J E SOLAR n ougwa TE91NLO1O TO BCi.A1E ITIV Y THE _ PASTACIER COMPANIES MA LECRE IEHAMOTMO CLE IMCM.EARED COX Y .PLL MATERIALS.NOMN'BIi MO w IUEE ceE0 WHICH MAT IEC NWA OSMS FOR ETIE WN OT GROUP° ._ _ SHALL CAaYOE�Mal INTERRUPTER T 4T0EDMI TEM ME TO ME EE RE �MMPARENT OORmWRV LPOIRPCAL RE ECCM9 (cam E . R T�M M.�dR.TO SE ..MMMM.MAGEamm 4 laccomeme art : l`I F n �ty GENERAL NOTES • SOLAR 41) IF BASS aoIEO IS MARKED OM.MINOR CHARACTER OTHER TIAN W.SLEADE NE ADVISED THAT FINAL WU/MAURNW SYSTEM OWMCnBSIR2 ME NAECT TO CHANGE DUE TO AY.E.WTY Cr FOUR/EMT _ nn Na Ns MOrin R.R,TYRfOa • • Nona:"ammo saw ssecsron soma olatmeas lams moons ao au Rooms.DotAtocan umoo-amt wore mounocus inc. moo Anton a 7 he (REM.Kiri iro-nrers rowooLorpoRoommoomm i .R. SOLAR MODALS =VILE { •111 41114 sows room(REFER To NoornooLITIER MR SPASM No REDA, ECOFASTEN l'FOOT IRAC FOIL I.i Ono Roc onnena• Ronne sot Rem ono • 11111111 wows.masons... in m wouolorosoccusAm. migucnos•le To use suancarioNnIATA oar fc4i too/Le I mw mo car.inn . ECOM.sluiRAMING—. j_consTo tocnompl an No.. Assooll SMNOLL23 roenamoDoomm•tonna)Root two sa,... ARCO SEALANT I ki I., la PAM DICES FOR Cel'Amen lomat.spLootaTion m.S1 .0) EXISTIMI RAMER oeonn000nosio„ot000teni A. GAMER REAVOiDart. :es/71 I?di ao•oonoRomm,A) rIATIACHMENT&CLIP OFTAIL riPV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF r-IHEIWIT FROM GROUND LEVEL TO PEM OF ROOF 1...brattooT To Duos I.JSGML PA r0 TOME Li sexy KA 70 sup! ARRAY SCHEDULE 1--------- (PROPERTY LINE ) -------- - Issued/Revisions I NO-" m000moom AA. A.m. DESCOPTION DAM II • Prayed Title: PENNING.ROBERT- . I TONT AULT it 201409-MAINI I Projed Address: • I SACS I I 10 BRADFORD RD WEST YARMOUTH,MA 02613 41.652238,-10.253145 I Drawing 196.:I OD Draw . . . I 1 I PROPOSED PVSOIAR SYSTEPA I F°X. I,Lk',11,1,.,...g,,t..., IN EI Drowns Inkarolion ' mmu I"' ono me I an) I owner: n 4.1 AO L„1.1 AIN : I I npvrAcHE I System Intonation: )II) 'CPS"Ute m mom sa a I Ii.eg gt A . Imo hicouu mum: F* 234 I . "MOM. moms ns 55 107 FROST I omicron A ariatolcom as son,Imo om Almon n mem ti L"‘"Y".""' onscos) lama Li TAM Nit wows Au.EOUIRUENT SHALL Se N•Toire Si Recoomlos VAIN THE MOUCActuRers ilisioaknopi learnucTiopit I s)APAInc•ass To coins woo mumsAciusER Room-kook I • AI Al LOCATON•RAE ApimosmAlt AND wows MELD outirscADas _ 4.1 mi VC ascoonrci SHALL RE GROHPEO Him mvERTER IS)WP .IS(E). 1 I F(v.No. Sheol s)auctunxneounon eovatawaincust witummaumintoRfinao --.—————————————————— 82 Rooney sotARRAHLLAnopiaLEIMPREAY POLL NA En:PO INECHRIHE EXISTING ROOF ECHE SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE P 1 PV - .2.) WV SPE" wan HEW MOOED IN CISCONNECT TON il WAITS in Ai ORYIsinsa _ _ OEII=nu°e.trAoc=17•4 1:3 me mu so ammo lull ITT Iccu ssniA I TOWE mouse 52 ~mos as 10AFAX-suc co.i295) Tr: > ,,., mot 1 mootruso I 100:01-1/5030NPICI ''' un i ty® non se 0 rcAltrISZas"nunturiAolo•dvErinDti.ESSA woromioet Sr n ........ REFER To EsoPmERT ScsesuLE Fon saws. loot z OTHER OBSTRUCTIONS mow) li Mor.AIESPEw IomxIlormAETER To RE DuENTARot Mr in Borns song ammo.RAHa. LOCATION Slim roman mosso SOLAR sown Inners OISCamiECT TOSEEA ROCKIES PEW WAITER TORE 7251 ni•oos Nod an-MS OREN-moot lir LQI moons mot somuro mom. WA.Notkom ono ••••••Nokus000m REFER To fouPRENI SCHEMA Fat*501. , • • . • . . E n o I n E E R s JOB NO.: 02041-1881-181 SUBJECT: CONNECTION PROJECT: Robert Rynning Residence Lag Screw Connection Capacity: Demand: Lag Screw Size[in]: -5/16 Max. Trib. Cd: 1.6 NDS Table 2.3.2 Pressure Max a (0.6 sfTributary (ft)2 Max. Uplift Embedment [in]: 2.5 s ) Width (ft) Force (lbs) Grade: SPF(G =0.42) iI • Zone Capacity [lbs/in]: 205 NDS Table 12.2A 1 21.7 J 5.3 :` 14.4 314 Number of Screws: 1 <! 2 26.1 ,0 5.3r 14.4 376 Prying Coefficient: 1.4 3 26.1 •=:;5.3,,, 14.4 376 Total Capacity [lbs]: 586 Demand< Capacity: CONNECTION OKAY 1. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag screw. Embedment in sheathing or other material is not effective.The length of the tapered tip is not part of the embedment length. 2.'Max.Trib Area'is the product of the'Max.Tributary Width'(along the rails)and 1/2 the panel width/height (perpendicular to the rails). JOB NO.: U2041-1881-181 VECTOR SUBJECT: WIND PRESSURE E rl O i f1 E ERS PROJECT: Robert Rynning Residence / Components and Cladding Wind Calculations Label: Solar Panel Array Note: Calculations per ASCE 7-10 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]: 140 Notes: Exposure Category: C Risk Category: II 9 ry� .,, w . + . .. ADDITIONAL INPUT&CALCULATIONS: Height of Roof, h [ft] 5 (Approximate) Comp/Cladding Location Gable Roofs` T< 58` 45° Enclosure Classification Enclosed Buildings Zone 1 GCP `'`1.0 Figure 30.4-2C (enter largest abs. value) Zone 2 GCP /,'„:' 1.2-- (enter largest abs. value) Zone 3 GCP: 1:2- (enter largest abs. value) a: 9.5 Table 26.9-1 z9 [ft]: 900 Table 26.9-1 Kh: 0.85 Table 30.3-1 Kn: 1 Equation 26.8-1 Ki: 0.85 Table 26.6-1 Velocity Pressure, qh [psf]: 36.2 Equation 30.3-1 GCP;: 0 Table 26.11-1 (largest abs. value) OUTPUT: p=q,,KGCP)—(GCpii Equation 30.9-1 Zone 1 Pressure, p [psf]: 36.2 psf(1.0 W, Interior Zones*) Zone 2 Pressure, p [psf]: 43.4 psf(1.0 W, End Zones') Zone 3 Pressure, p [psf]: 43.4 psf(1.0 W, Corner Zones*within a) (a= 3 ft)