Loading...
HomeMy WebLinkAbout45 CONGRESSIONAL POOLFENCE REQUIRED WHERE WALL >30" REVEAL z co CAP STONE UNITS W 11111-, 1 /2„ x 5 1 /4" I-= = _111-II � Fiberglass Pins 8" LOW PERMIABILITY SOIL COVER D X COARSE SAND BACKFILL AGAINST WALL FOR DRAINAGE ; 1 7C/) KEYSTONE OR EQUAL RETAINING WALL UNITS 18"X8" SET WITH 1 BATTER PE ROW FIBERGLASS PINS REQ. 6"X30" Crushed Rock or Unreinforced Concrete Leveling Pad req. RETAINING WALL CROSS SECTION NOT TO SCALE NOTES MITIGATION CALCULATIONS. 1. DATUM IS NAVD 88 PROPOSED HARDSCAPE 0-35' 35-50' TOTAL 2. MUNICIPAL WATER IS EXISTING 3. THIS PLAN IS FOR PROPOSED WORK ONLY AND 220 SF 775 SF 995 SF NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 2740 SF OF MITIGATION PROPOSED BETWEEN THE 0-50' OFFSET 4. CONTRACTOR SHALL BE RESPONSIBLE FOR FROM THE BWV. NATIVE SPECIES PLANTINGS PROPOSED IN CALLING DIGSAFE (1-888-344-7233) AND EXISTING LAWN, MULCH, AND GARDEN AREAS. VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 5. EXISTING SEPTIC LOCATION PER TIE —CARD ON FILE WITH THE TOWN. 6. WETLAND FLAGGED BY BRAD HALL OF BLH ENVIRONMENTAL CONSULTING. 7. AUTOMATIC POOL COVER PROPOSED. ZONE X (AREA OF MINIMAL , FLOOD HAZARD) 25� 26 ZONE X (0.2 PCT ANNUAL CHANCE S FLOOD HAZARD) 27 EXISTING RAILROAD TIE WALL TO BE I REMOVED EXISTING RETAINING WALL TO BE 70 RE —BUILT WITH CONCRETE BLOCK / EXISTING LAWN & . GARDEN AREAS -TO BE REPLANTED WITH NATIVE SPECIES 700, 9 (2740 SF TOTAL) STAKED SILT FENCE WORK LIMIT LINE SOME MITIGATION PLANTINGS TO TAKE G ° PLACE BEHIND WORK LIMIT LINE EXISTING BRICK PATIO TO BE REPLACED GE WITH BLUESTONE AC EXISTING LANDSCAPE TIES TO BE Q REMOVED —PROPOSED RETAINING WALL TO BE CONSTRUCTED ��Wr• � .] DCE ## 18-217 PATIO TOF=26.7 '�> EL. 25.6 AT WALKOUT WINDOW EXISTING DWELLING TO BE REMOVED FFLR=32.5t -[32.0] oF� X 2 P T qr<cy J L C AN UR235� 30 HA ARD PROPOSEiP00L CB FND Z E X (AREA 3,E�MENT AREA 0 M IFL D HAZARD) zo Scale:1 "= 20' I 0 10 20 30 40 50 FEET PATIO .q O O LOT AREA 27,400f S.F. GARAGE SLAB EL. 31.0 y`1 N 39 ,a, o Roa o Cb ik �10 Rfe 6A a fe 6A Sand I � roc « Locus o� Dennis Pond c X o m 0 LOCUS MAP SCALE 1 "=2000'f ASSESSORS MAP 103 PARCEL 12 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AND (0.2 PCT ANNUAL CHANCE FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001 CO559J DATED 7/16/2014 SITE IS WITHIN ZONE 11 ZONING SUMMARY ZONING DISTRICT: RS-40 RESIDENTIAL DISTRICT C MIN. LOT SIZE 40,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 20' _REAK -SE c, —_ _ 20' ' MAX. BUILDING COVERAGE 25% OWNER OF RECORD MICHAEL S. AND MARY-ALYCE BERNSTEIN 53 CONGRESSIONAL DRIVE YARMOUTH PORT, MA 02675 ® REFERENCES DEED BOOK 30519 PAGE 296 PLAN BOOK 234 PAGE 53 yam SITE PLAN CB FND RECEIVED OF OCT 0 1 12018 45 CONGRESSIONAL DRIVE �EA TH DEPT YARMOUTH PORT, MA PREPARED FOR MICHAEL BERNSTEIN t y 'w t DATE DANIEL A. OJALA, P.E., P.L.S. DATE: AUGUST 16, 2018 off 508-362-4541 I fax 508-362-9880 downcope.com 470WO cape efvineeliflf, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 18-217 BERNSTEIN.DWG