Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2017 Nov 09 - Sign Off Transmittal, Plans - New 3 BR House
_1ST FLOOR a GARAGE FLOOR 30 YEAR (MIN.) ROOF SHINGLES OVER IS* FELT PAPER OVER 1/2" CDX PLYSCORE (4 PLY MIN.) 12 10 ALUMINUM GUTTERS AND DOWNSPOUTS (TYP.) ........... Ll =I= M m GARAGE DOOR DESIGN TO BE VERIFIED j. i� RETAINING WALL- LXACT SIZE, LOCATION AND MATERIAL TO BE VERIFIED. (DESIGN BY OTHERS) wooll FL AT I FIRONT ELEVATION — - - — ( i f f✓1�1\L.iL►tVV �VVI\ THERMATRU 8210 OR EQ. DATE 9/22/201-1 DRAWING NO. LEE—YARM SCALE 1/4" U)U W UJ cr m � u 'zt 0 w W z O x � oFA a z U � A O � a F� U AFAB ENTERPRISES PO BOX 916 BURLINGTON, MA 01803 OFFICE (781)272-2156 FAX (781)229-6394 WWW.AFABHOMES.COM t n 1 w�'�®)Gilrh➢ Hecht, Depa 'tme1811pp 2 xvv jue Zz" Wte LNOV017 {�T LEFT ELEVATION PAGE I 11 INSULATION INSULATION VALUES TO BE MET VIA COMPLIANCE WITH THE PRESCRIPTIVE IECC 2012, SLABS - R-10 MIN (24" PERIMETER) BASEMENT - R-15 MIN, CONT. R-113 MIN. CAVITY (INTERIOR) CRAWLSPACE - R-15 MIN. CONT. R-19 MIN. CAVITY (INTERIOR) FLOORS - R-30 MIN WALLS - R-20 MIN CEILINGS - R-4'3 MIN WALL FENESTRATIONS- .32 SKYLIGHTS - U.55 MAX DOORS/HATCHES TO UNCONDITIONED SPACE MUST BE GASKETED E INSULATED TO MATCH SURROUNDING R-VALUE AIR SEALS- ALL JOINTS, SEAMS AND PENETRATIONS BETWEEN CONDITIONED AND UNCONDITIONED SPACE TO CREATE CONTINUOUS BARRIER. H,E,R.S, RATER TO SUPERSEDE VALUES LISTED IN THIS TABLE, ELECTRICAL SYMBOL SMOKE DETECTOR CO DETECTOR <�> SMOKE / CO COMBINATION HEAT DETECTOR SMOKE DETECTOR REQUIRED LOCATIONS. R314,3 SMOKE DETECTORS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS. 1, IN ALL BEDROOMS: AND 2. IN THE IMMEDIATE VICINITY OF BEDROOMS 3. IN EACH STORY OF A DWELLING: UNIT, INCLUDING BASEMENTS AND CELLARS BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. 5. FIXED TEMPERATURE HEAT DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF R314.5 I CARBON MONOXIDE DETECTOR SPECIFIC INSTALLATION PROVISIONS R315.2 i EVERY RESIDENTIAL STRUCTURE THAT PRESENTLY OR IN THE FUTURE CONTAINS FOSSIL FUEL 'I BURNING EQUIPMENT OR HAS ENCLOSED PARKING SHALL BE EQUIPPED, BY THE OWNER, LANDLORD OR SUPERINTENDENT, WITH WORKING AND LISTED CARBON MONOXIDE ALARM PROTECTION. (A) CARBON MONOXIDE ALARM PROTECTION SHALL BE LOCATED IN EACH LEVEL OF EACH DWELLING UNIT INCLUDING HABITABLE PORTIONS OF BASEMENTS, CELLARS AND ATTICS, BUT NOT INCLUDING CRAWL SPACES. (B) WHEN MOUNTING CARBON MONOXIDE ALARM PROTECTION ON A LEVEL OF A DWELLING UNIT WITH A SLEEPING AREA, THE ALARM SHALL BE INSTALLED IN THE IMMEDIATE VICINITY OF THE SLEEPING AREA, NOT TO EXCEED 10 FEET AS MEASURED IN ANY DIRECTION FROM ANY BEDROOM DOOR, FIRST FLOOR FLAN 9/22/201-1 DRAWING NO. LEE-YARM SCALE 1/4" z c~n cf) � W W v cr 0 zfy nferprd ONI flow AFAB ENTERPRISES PO BOX 916 BURLINGTON, MA 01803 OFFICE (781)272-2156 FAX (781)229-6394 WWW.AFABHOMES.COM PAGE �P 0 I4 R311.1.4.1 RISER HEIGHT. THE MAXIMUM RISER HEIGHT SHALL BE 8 1/411 . THE RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. THE GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/611, R311.1.4,2 TREAD DEPTH. THE MINIMUM TREAD DEPTH SHALL BE NINE INCHES. THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREADS LEADING EDGE. THE GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/&" INCH, WINDER TREADS SHALL HAVE A MINIMUM TREAD DEPTH EQUAL TO THE TREAD DEPTH OF THE STRAIGHT RUN PORTION OF THE STAIRS MEASURED AS ABOVE AT A POINT 12 INCHES FROM THE SIDE WHERE THE TREADS ARE NARROWER. WINDER TREADS SHALL HAVE A MINIMUM TREAD DEPTH OF THREE INCHES AT ANY POINT, WITHIN ANY FLIGHT OF STAIRS, THE GREATEST WINDER TREAD DEPTH AT THE 12 INCH WALK LINE SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/0". DATE 13/22/2011 DRAWING NO, LEE-` ARM SCALE 1/4V-0�� z cf) Gq U) W W _ R312.1 GUARDS REQUIRED. • GUARDS SHALL BE LOCATEDALONG OPEN -SIDED WALKING SURFACES, INCLUDING STAIRS, RAMPS, AND LANDINGS, THAT ARE LOCATED MORE 4'-4" 5'-2" 10'-6" 1'-O" 12'-11" S'_g" 4'-4" THAN 30" TO THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 36" HORIZONTALLY TO THE EDGE OF THE OPEN SIDE. INSECT SCREENING SHALL NOT BE CONSIDERED A GUARD, O R311,1.1 HANDRAILS. U w O HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH 4 OR MORE RISERS. 2'-6 x 4'42'-10 x 4 -9 2 -10 x 4'-9 2'-10 x 4 -9 2'-10 x 4 -9 2'-6 x 4'4Q H R311.1.1.1 HEIGHT. a/ HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPE PLANE 5 TH a ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF RAMP SLOPE, SHALL NOT BE '6 , 19-3/4 6-6 LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES. � I AT cf 01 ►w..l O Zll \ry P F--1 � � �3EDROOM #3 o i � � ►'�"� u A a � ATTIC: N # �� POSTS FROM RIDGE ALK O 5EDROOM 2 m ® TO SOLID BEARING a/ } N BELOW DOWN To cmIN p� LALLY COLUMNS CTYP� G OSET Q ill * L POST 2XWALLrL U l 0 x Q ----- 2'-6° 6 cn it M 0 fQ WALK �+ POST POST IN �--a Lu © in i AFAB ENTERPRISES PO BOX 916 BURLINGTON, MA 01803 OFFICE (781)272-2156 FAX (781)229-6394 WWW.AFABHOMES.COM PAGE czo '1 3 c SECOND FLOOR IOL4N