Loading...
HomeMy WebLinkAboutEngineered Plans - 2018Permit valid for REPAIR OF SEPTIC SYSTFM Board of lica.ith review and approval is required lor, any future addi,tions/rew)%ations/aIterations to LEGEND sewage facilities and/or structures/dwelling. Z f<<�s • gtic�� A CR vaim66 h Health i)eparttnent -- 100-- EXISTING CONTOUR PROV_D:�� x 100.98 EXISTING SPOT GRADE 729 \ W EXISTING WATER SERVICE WINTER ST lQ�9rrf� O� G EXISTING GAS SERVICE o (,l ADD VEN . & INSPECTION PORT EX/STING LEACH PITS H. W —OVERHEAD WIRES `ooti� pie Hate TO BE PUMPED, FILLED W/ ao SAND & ABANDONED. TEST PIT ti LOCUS N 28*46'10" W _ 100 BENCHMARK �UTE sn 98:E1­ TP79. Z O 10 71007 100,42 9 r- ; Po G 8 100:8 iPROP. 43.) SEPTIC 100:73 0 _ — T — r- TANK LOCUS MAP 000 W GENERAL NOTES: NOT TO SCALE �.101.10 W 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL 100,88 !/ BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS N -• EX/STING SEPTIC TANK OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE _ LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: PROPOSED S.A.S. X 100.32 + PATIO DECK TO BE PUMPED, FILLED WITH -310 CMR 15.405(1)(h): SAND AND ABANDONED. 1 A 1' reduction to the required 5' separation between maximum 4 ROWS OF 7 H-20 HI ) 9 P CAP INFILTRATOR UNITS 100,33 X BM seasonal high groundwater and bottom of S.A.S., for 4' sepataion. 101.40 PROPOSED SEWER 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE EXISTING SHED �O CONNECTION DESIGN ENGINEER. �j r� / 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING (TO BE RELOCATED) 7 � o FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN O. �, X EXISTING O ENGINEER BEFORE CONSTRUCTION CONTINUES. T.O. F.101.4 00., 100,42 HOUSE( .4 J.3E / o C 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. �y — y m 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF BENCHMARK X THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. OUTSIDE CORNER/BOTT. STEP 100:87 EL.10 1. 40 X 100:10 7. WATER SUPPLY PROVIDED BY TOWN WATER SUPPLY. = 100,92 8. THERE ARE NO POTABLE WELLS WITHIN 100 FT. OF THE PROPOSED 10 ,80 X 100:65 PROPOSED SEPTIC SYSTEM.. 3 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS LO1` 2 AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE p DIRECTED BY THE APPROVING AUTHORITIES. a 11 W36 S. F. c�' a 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 100,32 PLANTINGS ' / 80.00 PLANTINGS 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS 101,01 IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND S 2$'46'10" j U� '� REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3), OR AS I" OTHERWISE DIRECTED BY THE APPROVING AUTHORITY. 99,65 f 99 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE 99,70 . 99:51 HEALTH DEPT. i INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. s 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND OF Mgss9c 100,22 99,79 edge of 99,28 road 98 72 98.42 IS NOT TO BE USED FOR PROPERTY LINE OR ELEVATION CERTIFICATION. yG 14. THIS ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC o PETER T. PLAN REVISION - 10/16/18 SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. Mc WEIR ROAD ADD VARIANCE REQUEST PROPOSED SEPTIC SYSTEM UPGRADE PLAN o CIVIL "' PLAN REVISION - 10 11 /18 No. 35109 ADD SEPTIC TANK crST� ° �� OWNER of RECORD 16 WEIR ROAD, YARMOUTH PORT, MA A E DEXTER, JEFFERSON S Prepared for: DiBuono Sewer & Drain, 35 Content Lane, Cotuit, MA 02635 DEXTER, DINA G ` 4 Engineering b SCALE DRAWN JOB. N0. 16 WEIR ROAD 9 9 y' 1 °'=20' P.T.M. 211-18 PLAN REFERENCES: PLAN BOOK 129, PAGE 147 YARMOUTH PORT, MA 02675 Engineering Works, Inc. 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. CERTIFIED PLOT PLAN, YARMOUTH, MA, BY EDWARD KELLY RS, DATED 3/11/74 MAP ID: 124-78 (508) 477-5313 8/17/18 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL: 97.83 FOR A DISTANCE OF 15' AROUND THE SEPTIC TANK PROPOSED D-BOX PERIMETER OF THE S.A.S. INSTALL RISERS & COVERS OVER INLET & INSTALL RISER AND COVER SET TO WITHIN 6" OF FINISH PROPOSED S.A.S. OUTLET AND SET TO 6" OF FINISH GRADE GRADE INSTALL INSPECTION PORT OVER EACH ROW T.O.F.=101.43t I CHARCOAL 100.8f -F.G. EL.=100.9t EXISTING F.G. EL.=100.9f F.G. EL=100.8t F.G. EL.I ZZ VENT CONNECT e MAINTAINrRAnp- (mil ) nvpp c A c ALL ROWS L - 15' i + INSPECTION ® S=l% (MIN.) L = 18' L = 12' PORT 4"SCH40 PVC ®'SCH 0(PVC) 4 SCH40(PVC) 6" Io„I B' .1 4,. ill' TO INV.=98.15 48" LIQUID INVERT LEVEL INV.=97.90 INV.=97.53 GAS BAFFLE PROPOSED 4 ROWS OF 7 UNITS AT 6.25'/UNIT = 43.8' INV.=97.70 D-BOX INV.=96.62 H-10 RATED SOIL ABSORPTION SYSTEM (PROFILE) PROPOSED SEPTIC TANK SEWER CONNECTION ESTABLISH VEGETATIVE COVER INV.=98.30t BACKFILL WITH"aEAN NATIVE OR (VERIFY) �PERC SAND TO TOP OF CHAMBERS TOP ELEV.=97.03 NOTES: BREAKOUT=TOP 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INV. ELEV.= 96.62 INVERTS, PRIOR TO INSTALLATION. 2) SEPTIC TANK AND D-BOX SHALL BE SET LEVEL AND BOTTOM ELEV.= 95.70 III III�IIIII�II TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX 4' OF NATURALLY OCCURRING 2 83' INCH CRUSHED STONE BASE, AS SPECIFIED IN PERVIOUS MATERIAL 4' (MIN.) ABOVE G.W. EFFECTIVE WIDTH=11.3' 310 C& ( OUTLET TEES AS REQUIRED. WITH VARIANCE EXISTING SUITABLE 3) INSTALLL INLLETET & OUTLET W., EL=91.2 - MATERIAL 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE ADJ. G.- AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. USE 4 ROWS OF 7-HIGH CAPACITY H-20 INFILTRATOR UNITS SEPTIC SYSTEM PROFILE WITH NO SEPARATION BETWEEN EACH ROW & NO STONE TYPICAL SECTION N.T.S. DESIGN CRITERIA NUMBER OF BEDROOMS: 5 BEDROOMS SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <5 MIN/IN DAILY FLOW: 550 GPD DESIGN FLOW: 550 GPD GARBAGE GRINDER: NO PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY LEACHING AREA REQUIRED: (550 GPD) = 743.2 SF .74 GPD/SF DISTRIBUTION BOX: 3 OUTLETS (MINIMUM) USE 4 ROWS OF 7 HIGH CAPACITY INFILTRATOR 'r _43.8' -I I PR �I lL_ _ H-20 UNITS WITH NO STONE ALIGNED AS SHOWN SIDEWALL AREA: NOT APPLICABLE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF) (INFILTRATORS) 28 UNITS x 6.25 LF x 4.73 SF/LF = 827.8 SF DESIGN FLOW PROVIDED: 0.74 GPD/SF(827.8 SF) = 612.53 GPD NOMINAL BED AREA: 11.3' x 43.8' = 494.9 SF S.A.S. LAYOUT SOIL LOG DATE: JULY 11, 2018 SOIL EVALUATOR: PETER McENTEE PE WITNESS: AMY VON HONE R.S. HEALTH AGENT ELEy. TP-1 DEPTH 100.5 0 FILLL 98.6 A 23" LOAMY SAND 10YR 4/2 98.2 e 27" LOAMY SAND 10YR 5/4 97.2 C 40" PERC 34"/52" FINE SAND 2.5Y 6/6 91.2 ADJ. GW IV90.8 STG. GW 117" 90.5 120" GROUNDWATER ENCOUNTERED AT 117", PERC RATE <2 MIN/IN. SDW-252 NO DATA, AIW-247 VERY CLOSE TO LOCUS USE INDEX WELL AIW-147, ZONE B WATER LEVEL=21.1 (JUNE 2018), ADJUSTMENT=0.4', ESTIMATED HIGH G.W., EL.=91.2 000000 00 000 0000000 0000000 00000000 00000000 Closed End Plate Open End Plate •- View End View HIGH CAPACITY INFILTRATORS, H-20 LOADING INFILTRATOR CHAMBERS N.T.S. PROPOSED SEPTIC SYSTEM UPGRADE PLAN 16 WEIR ROAD, YARMOUTH PORT, MA Prepared for: DiBuono Sewer & Drain, 35 Content Lane, Cotuit, MA 02635 Engineering by: SCALE DRAWN JOB. NO, Engineering Works, Inc. N.T.S. P.T.M. 211-18 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 8/17/18 P.T.M. 2 Of 2