Loading...
HomeMy WebLinkAboutEngineered Plan - 2017000 EXISTING CONTOUR: - - - - PROPOSED CONTOUR:------------- 0 EXISTING SPOT ELEVATION: 25.5 N 00 A0 Z PROPOSED SPOT ELEVATION: 25.5 GN0 <2 TEST HOLE: * 4 UTILITY POLE: -p- 0 <Z FENCE LINE: 0� HYDRANT: �n 'Nk RETAINING WALL: LOCATION MAP LOT 93 (9,691 SF) ASSESSORS MAP: 49 PARCEL: 222 LAND COURT CASE 32827A FLOOD ZONE: AE (EL 12) 16 '�°ylv AT OUND 15.59 40' o .............I......... LEACH AREA DETAIL (LOW PROFILE FLOWDIFFUSORS) 01 'b cp SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC T:NK: 330 GAAY x 2 DAYS = 660 GAL USE 15ALLON SEPTIC TANK LEACHING AREA: USE 4 LOW PROFILE FLOWDIFFUSORS WITH 3' OF STONE AROUND SIDES AND 4' AT ENDS (40' x 10' x 6" EFF. DEPTH) SIDE AREA: (40, + 10') x 2 x 6/12 = 50 SF (0,74) = 37 GAL/DAY BOTTOM AREA: 40' x 10' = 400 SF (0.74) = 296 GAUDAY CAPACITY = 333 GAL/DAY ,���JGOOt3` 14 1 II I 1 TOP OF COASTAL BANK I .2 4 -9 12 10- - 8-•--- / M 17-24 SEPTIC SYSTEM SECTION 14.87 COVERS WITHIN 6" TOP OF OF FINISHED GRADE FOUNDATION 12.7 , �typi �' �3' MAX. 3 ELEV. 4 COVER (2 EXISTING a 12.13 (1' MIN) PIPES TO 1500 GAL ELEV. - BE COMBINED) - 12.38 SEPTIC TANK 12.03 11.86 l ELEV. ELEV. D-BOX ELEV. ° (6" STONE UNDER OR OF STONE UNDER OR MECHANICALLY COMPACTED) (6" MMECHANICALLY COMPACTED) TEE SIZES: 1 1. 63 INLET: 6" UP, 13" DOWN ELEV. OUTLET: 6" UP, 14" DOWN GAS BAFFLE AT OUTLET TEE KITCHEN DINING deck ROOM_ LIVING ROOM deck TEST HOLE LOGS LATH BED ENGINEER: THOMAS MCLELLAN, P.E. ROOM WITNESS: AMY VON HONE, R.S. DATE: 5-17-17 PERCOLATION RATE: <2 MIN/IN ROBED) OROOM EXISTING FLOOR PLAN Yarmouth Health Department AFp..COVED Name - Date P�ZN OFMAS. a� �cyG ' TERRY sM l°VARNER NO..38721 c 2" PEASTONE OR FILTER FABRIC - 3/4" - 1 1/2" DOUBLE WASHED STONE INSPECTION PORT ,- ELEV =12.21 -"" .LI ►11.13 3H-4' 3 4� ELEV. F 40' x 10' 4 LOW PROFILE FLOWDIFFUSORS WITH 3' OF STONE AROUND SIDES AND 4' AT ENDS (40' x IO' x 6" DEEP) (H-20) TH-1 15.0 O/A HORIZON ELEV. LOAMY SAND 6" 10YR 4/1 14.5 B HORIZON LOAMY SAND 26" 1 OYR 5/8 2,8 Cl HORIZON .. MED-FINE SAND 96" 2.5Y 7/4 7.0 C2 HORIZON SILT LOAM 108" 2.5Y 6/4 6.0 C3 HORIZON MED- SAND 144"1 2.5Y 7/4 3.0 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/8" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D-BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING CESS POOL IS TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14, D-BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 15. WORK LIMIT LINE, AS SHOWN, TO BE SET PRIOR TO CONSTRUCTION. LINE TO BE STAKED SILT FENCE. 10, COUTRACTOR T SMALL AMOUNT OF C2 HORIZON (SILT LOAM, APPROX. 9' DEEP) UNDER LEylff��REA ND REPLACE WITH CLEAN MEDIUM SAND. 00' 014 H 18 HEALTH DEPT J. SITE PLAN LOCATION: 68 GROUSE LANE, W. YARMOUTH, MA PREPARED FOR: PATRICIA LOTTI DATE: 5-19-17 SCALE: 1" = 20' BASS RIVER ENGINEERING p,E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048