HomeMy WebLinkAboutEngineered Plan - 2018ACCESS COVERS MUST BE WITHIN 6- OF FINISH GRADE FIRST 2' TO IN BE LEVEL-7 OAS INSPECTION 9' MINIMUM, PORT 6' MAXIMUM COVER 4'VENT WITH CHARCOAL FILTER i8- MIN r=EffCLEAN SAND BACKF I L L 11� H-20 AROUND AND 2' OVER CHAMBERS 1 1 1 6 OUTLET 24 HIGH CAPACITY INFILTRATOR EXISTING D-BOX CHAMBERS IN BED FORMATION I1000 GAL H-20 j SEPTIC TANK 16* CRUSHED STONE OR 1 \' COMPACTED BASE v PROFILE : NOT TO SCALE L OCUS MAP INVERT ELEVATIONS: INVERT OUT SEPTIC TANK: 100.2 INVERT IN DIST. BOX: 99.47 INVERT OUT DIST. BOX: 99.3 INVERT IN LEACH CHAMBER: 99.22 BOTTOM OF LEACH CHAMBER: 98.3 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WA TER : N/A BOTTOM OF TEST HOLE * 1 : 91.0 DESIGN CRITERIA: DESIGN FLOW: 4 BEDROOMS AT 1 /0 G.P.D. PER BEDROOM EQUALS 440 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 440 G.P.D. X 200% - 880 GAL. SEPTIC TANK PROVIDED. 1000 GAL. EXISTING SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE l 9 MIN/INCH SOIL TEXTURAL CLASS - I EFFL UENT L OAD I NG RA TE - 0.74 GPD/SF 440 GPD / 0.74 GPD/SF - 595 S.F. REQUIRED PROVIDED: 24 H16H CAPACITY INFILTRATOR CHAMBERS. 150 ' x 4.73 SF/FT - 709 S.F. \ \ - 709 S.F. x 0. 74 - 525 GPD \\ \\ N EDW 1 \\ \\ \\ \\ (0 A REA 39.9/0± S.F. EOW 2 -�441 Ew T 96, { \ 98-----_- _ -#-n9 2 *_- 03 / `------ CD SAIED 101.7 02. 7+,EDGF 0/. +102.7 °jH/NG D-BOX X/ST/NC 3� S , - - ` 103.2 - + - C 24 H10 CAPACITY W 36 -OAK 1AFIL-TRATOR CHAMBERS IOS.I � 04 \ VENT RO LNG ty OfCN _D R-AS-BJ/LT LOCATION EXISTING / CHER_ R�" 20' , SEPTI C,YANK - , 12 "SEECH��- / E R00hf i 14 .BEECH- - - - / / { LAWN 10_6 20 "BEECH .� !2"BEECH 106.3 12'4 16'BEECH 13 -W O G OHW -f ---T - CTV + 40.4 .. 40- 40 l "- 20' JULY 3/ . 20/8 STEPHEN A. HAAS ENGINEERING, I N C -- UNDERGROUND TELEPHONE LINE (?- , "- :, P.O. Box 16 UNDERGROUND CABLEVI S l ON LINE M A O 2 6 6 U SPOT ELEVATION as�c Date 508) 362-8 1 32 EXISTING CONTOUR PROPOSED CONTOUR GENERAL NO TES : I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERT I CAL DATUM IS ASSUMED, FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MA TER I AL S AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E. P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3 ' IN DEPTH SHALL BE CAPABLE OF Wl TH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D-BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D-BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE`. 1-888-016-SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES, 8. EXISTING LEACH FIELD TO BE ABANDONED. SOIL TEST PIT DATA INDICATES � INDICATES PERCOLATION = OBSERVED TEST ? GROUNDWATER 0' HORIZON TEXTURE COLOR 104.0 BfDROpy A LOAMY IOYR SAND 3/4 10' ----- -- -- -- - --- 103.2 B LOAMY IOYR 94ZH SAND 5/6 30' --- -- ---- -- - - -- 101.5 BfDROOy C I FINE-MED IOYR SAND 7/4 _- EaROd� 60.'_ ------------.--- _-. 99.0 80' FINE LOAMY C2 IOYR SAND FIRM 6/2 96' - -------- -- -- -- 96.0 C3 MEDIUM IOYR SAND 6/6 SECOND FLOOR PLAN 156.1 NO WATER 91.0 DATE: JULY 22. 2015 TEST BY: STEPHEN HAAS WITNESSED VARIANCES REQUIRED: PERCC RATE: BI 4 MIN/INCH E TITLE 5. MAXIMUM FEASIBLE COMPLIANCE SECTION 15.221:(7) GENERAL CONSTRUCTION REQUIREMENTS FOR ALL SYSTEM COMPONENTS THE TOP OF ALL SYSTEM COMPONENTS SHALL BE NO DEEPER THAN 36' BELOW GRADE. A VARIANCE IS REQUIRED FOR THE SAS TO BE BETWEEN 4 • AND 6* DEEP. TOWN OF YARMOUTH SUBSURFACE SEWAGE DISPOSAL REGULATIONS REGULATION 3.7: DISTANCES & LOCATION OF DISPOSAL FACILITIES l 00 ' IS REQUIRED BETWEEN THE SAS AND A WETLAND. 85 ' IS PROVIDED TO A VEGETATED WETLAND. A I5' VARIANCE IS REQUESTED. SHRUBS Ec�RNER SH2��E'CH'', 20'BEEiH--------`I07.0 S � P T / C S f S / E7/ V/ LD E7 S / ON V + 106.4 /' 6 "BEECH ' +107.7-AdA PINE 18-PINE 62 HOMESTEAD LANE . MAP 132. PARCEL l 8 2 ' , N,7a2O.2p-ly LEGEND -------- - . / o �- ------ _ Permit y:afid for REPAIR Ol ' aa'"I IC SY5 t CB CONCRETE BOUND ` ' N_LY, clue, to State and C00 �clatic. variances. WATER L /NE 8S• Op _ 73oar�l:of licalth review •and'a0i;r o%;il i, required for HYDRANT N >>°2/ 20. -"v` future additions/rcwivr ions/alterations to lr YARMOUTHPOR T . MA. PREPARED FOR: D I ANA SAWYER GAS LINE sewage ,,. :'saes andlor structu .+/d��c uag. S CA L E OVER HEAD WIRES Yannotith iic'.w.- >cpartinent LIGHT POST API' (" V Ei / UNDERGROUND ELECTRIC LINE JOB NO: l 5 - 040