Loading...
HomeMy WebLinkAboutEngineered Plans - 2018102,17 O'A08,44 / i / JO- ANNA DRIVE 104.57 edge of 106,27 pavement 104,87 iV 74'00'50" E / 10&00 109.73 125.00 .. zu . �. e A'%4 108.90 % 103.14 x 040 ��/ /�CID x 110,63 x 1 1,41 x / i 1019.97 �:::.. /f 106,82 i 111.05, 106,27// �j X10,41 x 111.31 i w 112 90 x / P. 106.04 z U7 Cn �� \ o 0 0 105.28 EXISTING SEPTIC TANK TOP OF TANK, EL.=107.14 IN V. (OU T)=105.80E EXISTING LEACH PIT - TO BE PUMPED, FILLED W/ SAND & ABANDONED. BENCHMARK OUTSIDE COR./LANDING EL.=109.06 105.87 106.36 .EXISTING HOUSE( (25)� / T.O. F. =112.33E 114.36 106,84 108.31 I x �11.75 to G S/ 1 cr 0 /PORCH DECK 11 o Q m i BM 109.06 111,00 x 115,10 ( x 111.43 I fence ARBO x �09,79 I , LOT 10 f 19,375±S.F. I PARCEL ID: 100-'p31 � I { + 110,60 I I \ I I ( 125.00' x 1h1,70 S 74'00'50" W 114.81 x SOUTH YARMOUTH, AM 02664 Cape & Vinyard Electric Company Easement 1" r OWNER OF RECORD BALLO, PATRICIA J 25 JO-ANNA ROAD LEGEND - - 98 - - EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE ---& H. W.-- OVERHEAD WIRES EXISTING WATER SERVICE W G EXISTING GAS SERVICE TEST PIT i� BENCHMARK rd0%.s i F ; - tgwrl. - Yarmouth Health Department /�,PP�tCj�VED ROUTE 6 N ,Path o� Blua.� 0 e R RR R.O.W. ms� k Rd o _ �o, 0 S a Jo-Anno Dr •a d � Creaf � z �eStProLOCUSo� Put"n U 011 doh 9 Green � a Blue �a Golf Club LOCUS MAP- ;,c_ s'a'`' 'I NOT TO SCALE 1 llqz�6 'I I L-j V'r - h ' fr f13 me .Date RAL NOTES: -tee 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON AN ASSIGNED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WITHIN 150' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND o PETER T. REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). McENTEE 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE CIVIL "' INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. No. 35109 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND RfGIST��" NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. S$ L 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN 5wI ^�'k �N` PROPOSED SEPTIC SYSTEM UPGRADE PLAN 25 JO-ANNA DRIVE, SOUTH YARMOUTH, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. 1 "=20' P.T.M. 170-18 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET No. (508) 477-5313 5/31/18 P.T.M. 1 Of 2 SEPTIC TANK PROPOSED D—BOX INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & WATERTIGHT OUTLET AND SET TO 6" OF FINISH GRADE COVER SET TO 6" OF GRADE T.O.F. =1 12.33f -F.G. EL.=108.5f Iffilmmu F.G. EL.=108.3f F.G. EL.=107.0f xM 2 O S=1%(MIN.) @ S=1%1 (MIN.) 4"SCH40 PVC 4"SCH40 PVC 4" EXISTING 48" LIQUID - LEVEL ADD GAS BAFFLE INV.=104.27-J PROPOSED `INV.=104.10 INV.=105.8 D—BOX INV.=104.0 - NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES & INVERTS EXITING HOUSE, PRIOR TO INSTALLATION. 2) D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. TOP CONC. ELEV.=104.8t BREAKOUT ELEV.=104.50 INV. ELEV.=104.00 BOTTOM ELEV.=102.00 4' OF NATURALLY OCCURRIN( PERVIOUS MATERIAL 5' (MIN.) ABOVE G.W. NO G.W., EL=96. NOTE: TO PREVENT 'BREAKOUT, FINAL GRADE SHALL NOT BE AT, OR BELOW, EL.=104.5 FOR A DISTANCE OF 15' FROM THE EDGE OF THE PROPOSED S.A.S. PROPOSED S.A.S. INSTALL RISER & COVER OVER ONE CHAMBER AND SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT r F.G. EL.=107.0f MAINTAIN 2% SLOPE OVER S.A.S. -2" LAYER OF 1 /8" TO 1/2- DOUBLE WASHED STONE (OR APPROVED FILTER FABRIC) -3/4" TO 1-1/2" DOUBLE 4' 4.8' 4' WASHED STONE EFFECTIVE WIDTH = 12.8' SURROUNDED WITH STONE AS (SHOWN H-10 RATED SEPTIC SYSTEM PROFILE N.T.S. DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOMS SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 G.P.D. DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO —not allowed with design LEACHING AREA REQUIRED: (330) = 445.9 S.F. .74 EXISTING SEPTIC TANK: 1000 GALLON CAPACITY PROPOSED D—BOX: 1 INLET, 3 OUTLETS, H-20 RATED I SOIL LOG DATE: MAY 23, 2018 SOIL EVALUATOR: PETER McENTEE PE WITNESS: AMY VON HONE R.S. HEALTH AGENT ELEV. TP 1 DEPTH 107.9 A 0" LOAMY SAND 107.3 10YR 4/2 B 7., LOAMY SAND 10YR 5/4 105.1 C 33" PERC HOUSE&25) lb SEPTIC LAYOUT F S En t=1Big 1t�l t�l tit l�f t�l t�l 102 4" KNOCKOUT 20" DIA. COVER 4" KNOCKOUT 0 / 4" KNOCKOUT 4" KNOCKOUT 500 GALLON CAPACITY, H-20 LOADING CHAMBERS 58" USE 2-500 GALLON LEACHING CHAMBERS SURROUNDED BY DOUBLE WASHED STONE IN SERIES ON ALL SIDES M-C SAND 2.5Y 6/4 20% GRAVEL 96•6 136" PERC RATE 2 MIN/IN. NO GROUNDWATER' ENCOUNTERED PROPOSED SEPTIC SYSTEM UPGRADE PLAN 25 JO—ANNA DRIVE, SOUTH YARMOUTH, MA SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F. BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F. TOTAL AREA: .................���.. ........ ...... . .. . . .. . ..471.2 S.F. _ DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) 348.7 GPD Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 Engineering by: Engineering Works, Inc. 12 West Crossfield Road, Forestdole, MA 02644 (508) 477-5313 SCALE N.T.S. DRAWN P.T.M. JOB. NO. 170-18 DATE 5/31/18 CHECKED P.T.M. SHEET No. 2 of 2