Loading...
HomeMy WebLinkAboutEngineered Plan - 2018 (2)N KEY: EXISTING CONTOUR: - — — - 4 PROPOSED CONTOUR: ------------- LOCUS EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 �� Cy TEST HOLE: + UTILITY POLE: -O- �� FENCE LINE: - HYDRANT:-b- BUCK RETAINING WALL: ISLAND ROAD O ���NSLaO OCTION MP LOTS 178, 180,180 A, 81 (21,621 SF) ASSESSORS MAP: 49 PARCEL: 93.1 DEED BOOK: 16071, PAGE: 37 a: M18-31 26.64' _ N LEACH AREA DETAIL SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK (EXISTING) LEACHING AREA: USE 3 INFILTRATOR 3050 CHAMBERS WITH 4' OF STONE AROUND SIDES AND 2' AT ENDS (26.64' x 12.25' x 2' EFFECTIVE DEPTH) SIDE AREA: (26.64' + 12.25') x 2 x 2 = 156 SF (0.74) = 115 GAL/DAY BOTTOM AREA: 26.64' x 12.25' = 326 SF (0.74) = 241 GAUDAY CAPACITY = 356 GAL/DAY `� YVpIK Ed9p of Pav` A=26.79, BUCK "SLANn �- SEPTIC SYSTEM SECTION 106.96 a TOP OF FOUNDATION 103.7 ELEV. Q (EXISTING) a 102.45 a ELEV. COVERS WITHIN OF FINISHED GR 1 /8" per ft (EXISTING) 1500 GAL SEPTIC TANK TEE SIZES: (TO BE CONFIRMED) INLET: 6" UP, 13 DOWN OUTLET: 6" UP, 14" DOWN bath room4 bed room open to below 2nd floor bh bath] kitchen bed living room Uroom 1stfloor I EXISTING FLOOR PLAN I 1/8" per ft . I (1' M ELEV. 101.93 101.76 ELEV. D-BOX ELEV. 6" STONE UNDER OR MEC ANICALLY COMPACTED) - GAS BAFFLE 101.7, AT OUTLET TEE ELEV TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 6-6-18 PERCOLATION RATE: < 2 MIN/IN USGS GROUND WATER ADJUSTMENT: WELL: MIW-29, ZONE: A, ADJ. (MAY): 0.4' ADJUSTED GROUND WATER ELEV.= 93.9 NOTES: 2" PEASTONE OR FILTER FABRIC 3/4" - 1 1/2" DOUBLE WASHED STONE -INSPECTION PORT , ELEV.= 102.22 LC 111°I1°I1°I1°I1°I1°I1°I1°I1°II°II°II°I1°I1°II°I1ICI 99.72 2-4 4 ELEV. �e 26.64' x 12.25' 5.82' 3 INFILTRATOR 3050 CHAMBERS WITH 4' OF STONE AROUND SIDES AND 2' AT ENDS (26.64' x 12.25' x 2' EFFECTIVE DEPTH) ADJUSTED GROUND WATER ELEVATION = 93.9 TH-1 105.0 ELEV 17" FILL O/A HORIZON LOAMY SAND P4,, 10YR 3/1 103.0 B HORIZON LOAMY AND a PERC AT 36" 36" 10YR 6/8 1 102.0 C HORIZON MEDIUM SAND 2.5Y 714 OBSERVED ...... A.. ,93.5 GROUND WATER 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. --3,-SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/8" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D-BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3' WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING LEACH AREA (4 INFILTRATORS WITH STONE 36' x 11') IS TO BE ABANDONED. TH'OMAS J SITE PLAN LOCATION: 6 LAKE RD EAST, W. YARMOUTH, MA PREPARED FOR: KIM GOMEZ DATE: 6-6-18 SCALE: i" = 30' BASS RIVER ENGINEERING P.E. P.O. BOX 1163, EAST DENNIS, NIA 02641 508-364-9048