Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 2014WEST YARMOUTH HISTORIC EL_13.7 LOT 7 i-- H \ \ NroLOT 8 \ AREA=.58 ACRES\ \ \ \ 24.0' \ — W \ o. 0 C O I I 3s.2� I �O o. \ r?6, LAM / O� PUMP, ,CRUSH AND ABANDON LEACHPIT 0/ \ c'r B.M.: RIM \ 4PER TITLE 5 Z \ ` o EL=27.48 0 G I*SEE HOUSE LAYOUT ATTACHMENT 'k #16 8 TOF=29.08 ' G' W �PRp,GE i i DECK N CO N N SUNDER-- GROUND U TII LS I ' • l�9' 42 E 20 L— LOT 9 n a -) 0 N o U U J o Z 0 r r r N v permit valid for REPAIR �t F SEPTIC SYSTEM 00 00 ONLY, due to State and— al septic variances. Board of Health review an oval is required for ny future additions/re '1 ns/alterations to age facilities and/or stra nn dwelling. Yarmouth Health`�epariment c� APPROVED o � 31' � GRAPHIC SCALE 10 20 40 ( IN FEET ) 1 inch = 20 ft. !f� Dole MOMW D SEP 11 2014 HEALTH DEPT. 80 LOCUS MAP LOCUS INFORMATION PLAN REF: LCP 30949C TITLE REF: D1056269 PARCEL ID: MAP 46 PAR. 77 IN STATE ZONE II R-25 FLOOD ZONE: "C" COMMUNITY PANEL: 250015-0001—D DATED:07/02/92 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 168 HIGGINS CROWELL ROAD WEST YARMOUTH, MA. PREPARED FOR GERALDINE V. CHAMBERLAIN AUGUST (5), (19) 2014 REV. SEPTAO, 2014 OF MAss D VIQ R 17AR�P R OF MA,SS9 cy EDWARD Gs gg A. -A ° STONE No. 0 ¢ o � �o G/S le E. A. S. SURVEY, INC. 141 ROUTE 6A SALT POND BUILDING P.O. BOX 1729 SANDWICH, MA. 02563 BUS: (508)888-3619 CELL: (508)527-3600 SHEET 1 OF 2 J 1679 TOP OF FOUNDATION EL= 29.08' 10' MINIMUM --►� EL= 28.3' 4" SCHEDULE 40 P.V.C. MIN. PITCH 1 /4" PER FOOT 10' EXI ST. EXIST. INVERT INVFRT EL=25.41' EL= 27.7' 6" MAX. 6" MAX. MIN. 1 14"I 4' GAS G I BAFFLE EXISTING 1,000 GALLON TANK (TO REMAIN) GENERAL NOTES 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. ALL ACCESS PORTS OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 6" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10' OF DRIVES OR PARKING AREAS THEN THEY MUST WITHSTAND H-20 LOADING. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 2% GRADE OVER THE S.A.S. AND DISTRIBUTION BOX. "7. SEPTIC TANK SANITARY TEES SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEANOUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES. 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONTRUCTED OF 4" PVC. 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND FIRST TWO FEET OUT OF THE DISTRIBUTION BOX SHALL BE LEVEL. 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO E.A.S. SURVEYING, INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. 13. PROPOSED SEPTIC SYSTEM IS WITHIN STATE APPROVED ZONE 11 2s.4s' 5' S= .02 CONSTRUCTION NOTES: 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE OR A COMPARABLE MEANS. F=25.24 EL= 25.13' INVERT (EXIST.) 4" SCHEDULE 40 P.V.C. MIN. PITCH 1/8" PER FOOT CONC. RISER & LEVEL COVER FOR 2' EXISTING DISTRIBUTION BOX (H-20) CONC. RISER & LEVEL COVER FOR 12' iin J1 6" BASE OF MECHANICALLY r COMPACTED SAND PROPOSED DB3 DISTRIBUTION BOX W/"T" TEST PIT PROFILE OF SEWAGE DISPOSAL SYSTEM (NOT TO SCALE) EL= 24.0 ... ........ \en::::.`Cti.., 6" MAX. , INVERT CLEAN SAND FILL EL= 20.75 ��� PER 310 CMR 15.255 EL= 21.5 0 0 0 0 0 00 00 0 0 cp •o > 0 00 3/4" TO 1-1/2" DOUBLE WASHED STONE i RESULTS: 8.5' _ I (TYP. ) 25' 2" LAYER OF 1 /8" - 1 /2" DOUBLE WASHED STONE OR FILTER FABRIC EL= 24.0 9" MIN./ 36" MAX. A 0 00 00 ' � 0 'p Oct) 0co 2-500 GAL. (H-10) DRY WELLS (4'-10" X 8)-6 X 3)-0") N LO SOIL ABSORBTION (TRENCH FORMATION) SYSTEM (S.A.S.) 13' X 25' MIW29 JUNE 2014 OBS WELL 8.61 ZONE B ADJ. +2.9 ELEV.= 13.5 BOTTOM OF TEST HOLE ELEV.= 10.6' if DESIGN DATA: SOIL TEST DATE: JUNE 19, 2014 B.O.H. AGENT: AMY VON HONES R.S. SOIL EVALUATOR: EDWARD A. STONE, PLS BACKHOE: RODNEY FISHER TH EL.= 23.6 (PERC BOTCH 60"<2 MPI) ELEV. DEPTH (IN.) HORIZON TEXTURE COLOR IMOTTLING OTHER 23.1 0"-6" O/A LOAMY SAND 1OYR4/3 22.6 6"-12" E LOAMY SAND 1OYR5/1 N/A 21.3 12"-28" B LOAMY SAND I 7.5YR6/6 N/A 10.6 28"-156" C MEDIUM SAND 2.5Y7/4 N/A PERC DAMP 0 156" ELEV=10.6 VARIANCE REQUESTED: 1) WETLANDS TO S.A.S. (CODE 100') PROVIDED 71', REQUESTED 29' NUMBER OF BEDROOMS ......... ____ 3 _ GARBAGE DISPOSAL ................. - NO TOTAL ESTIMATED FLOW (110 GAL./BR./DAY X 3 BR.) -_330 330GPD X 200% = 660 GAL USE PROPOSED 1500 GAL. SEPTIC TANK INSTALL: 2-500 GAL. DRY WELLS (W/4' CRUSHED STONE ON THE SIDES, 4' ON THE ENDS) AND BACKFILL WITH CLEAN SAND FILL PER 310 CMR 15.255 SOIL CLASSIFICATION ................ ___1____ DESIGN PERCOLATION RATE..... EFFLUENT LOADING RATE ......... ___74___ REQUIRED LEACHING CAPACITY ..... 330 GALZDAY LEACHING CAPACITY PROVIDED ...... 352 GAL/DAY SIDEWALL: (13' + 25')x2x(2 SIDES)(.74)= 112 GAL/DAY BOTTOM: (13' x 25')(.74)= 240 GAL/DAY TOTAL= 352 GAL/DAY 352 GPD PROVIDED - 330 GPD REQUIRED = 22 GPD RESERVE viSS��`. P j ��,H OF IMgs D 'o� EDWARD Y_JR xi�� STOIVt PISTE LgNITAR q SEPTIC SYSTEM DETAIL PAGE #168 HIGGINS CROWELL ROAD WEST YARMOUTH, MA. AUGUST (5), (19) 2014 REV. SEPT. 10, 2014 SHEET 2 OF 2 J# 1679