BLDSM-19-003104
fit I i HOME ENERGY RATERS LLC 3 „ • BUILDING PERFORMANCE TESTING -,. c c ..t sr ' I\- °°31°4 Duct Leakage Report 147 berry ave. Test Mode RECEIVED Yarmouth Pressurization 11/29/2018 Test Pressure I DEC 03 2018 25.0 Pascals Daley HVAC BUILDING DEPARTMENT Testing Equipment By 2015 IECC Energy Code Minneapolis Total CFM®25 or Total Duct Leakage Percentage 29.00 0.04 Total Square Footage 824.00 Maximum Allowable Leakage 32.96 HVAC Duct Test Location ,,s : '-Sgit Servetl a .';, , ':Fancily" ;,.CFMws Gauge. t :;Duct Leakage.%• 4. 1 attic 824 C 29 N at 0.04 4 — U. ... • 180 STATE ROAD SUITE 2U SAGAMORE BEACH,MA 02582-(508)833-3100-ENERGYCODEHELP.COM-INFOCENER6YCODEHE1P.COM powered bygocarnas WWW.aocanvas.com 647A5738-C59C-4A80-8A65-24E7DA6F9254 a J RECEIVED • /01.p.,,-.42:4\ ' SHEET METAL PERMIT NOV j 9 208 444.4:1 .g Commonwealth of Massachusetts �.7�'` BUILDING DEPARTMENT 8 -.,,Y � Town of Yarmouth Building Department BY ___ � � Date: 11-19-101? Permit#: i3 tr'' 1 —(9'03/° V Estimated lob Cost:$ 7,,000 Permit Fee: $ Plans Submitted: YES/ NO Plans Reviewed: YES/ NO Business License # Application License# 1%15 Business Information Property Owner/Job Location Information Name: tsL1 4.V.k(. Name: TIRO ua tn2S Street: 23 SToak 'lGfl q Ldp. Street: 1/{-7 &R.Y.y AR City/Town: 11 I, City/Town: (IJ.yATof Telephone: -7-4-tic-- drt o Telephone: Sig Xco- 3ccd Photo I.D. required/Copy of Photo I.D. attached: YES/ NO Staff Initial: 1-1/C.-.1 unrestricted license J-2/ M-2 restricted to dwellings 3 stories or less and commercial up to 10,000 sq. ft./2 stories or less Residential: 1-2 family t Multl-family_ Condo/Townhouses_ Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq.ft.✓ over 10,000 sq. ft._Number of stories: Sheet metal work to be completed:/ New work V Renovation:_ HVAC Metal Watershed Roofing:_ Kitchen Exhaust System:_Metal Chimney/Vents:_Air Balancing:_ Provide detailed description of work to be done: n 4uc`c & Th. is taiic,To SA,cji, t l-Li G4s •PGri !_ 6 1 il V INSURANCE COVERAGE: I have a current liability insance policy or its equivalent which meets the requirements of • M.G.L. Ch. 112 Yes (f No If you have checked yea, indic to the type of coverage by checking the appropriate box below: A liability insurance policy V Other type of indemnity_Bond_ OWNER'S INSURANCE WAIVER:I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. • Check One Only Owner_ Agent Signature of Owner or Owner's Agent • By checking here4__I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installation performed under the permit Issued for this application will be In compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. • Inspections shall be called for prior to insulation installation. Duct inspection required prior to insulation installation: Yes No Date: Comments: Date: Comments: • T,yp/e of license: By: �/ Master Title: Master-Restricted t Signature of Licensee t City/Town: _ Journeyperson Permit#: Journeyperson-Restricted License Number 1515 Fee: $ Check atwww.mass.gov/dpi t Inspector Signature of Permit t of Permit Approval RIGHT-J SHORT FORM ° 0 Entire House CLIMATROL HVAC DESIGNS Job:CL53DAILEY 11-14-2018 3170 MATECUMBE KEY ROAD UNIT 127,PUNTA GORDA,FL 33955 Phone:508-351-5198 Fax 941-575-0013 Emat MILLERHVACDESIGNS@GMAILCOM Project Information For:. MATT DAILEY HVAC 147 BERRY AVE,WEST YARMOUTH, MA Design Information Htg Clg Infiltration Outside db(°F) 10 88 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD (°F) 60 13 Fireplaces 0 Daily range - M Inside humidity(%) - 50 Moisture difference(grAb) - 28 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Efficiency 80.0 AFUE Efficiency 13.0 EER Heating input 0 Btuh Sensible coding 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temperature rise 0 °F Total cooling 0 Btuh Actual heating fan 800 cfm Actual coding fan 800 cfm Heating airflow factor 0.029 cfm/Btuh Coding air flow factor 0.038 cfm/Btuh Space thermostat Load sensible heat ratio 86 % ROOM NAME Area Htg load Clg load Htg AVF CIgAVF (ft2) (Btuh) (Btuh) (cfm) (cfm) BED 1 126 3738 2759 107 104 LIVING 154 5872 5481 168 206 DEN 117 3585 1651 102 62 BED 2 121 3634 2738 104 103 BATH 40 856 275 24 10 KITCHEN 132 2585 2310 74 87 BED 3 100 .7725 6092 221 229 Entire House d 790 27994 21304 , 800 800 Ventilation air 3300 715 Equip. © 0.93 RSM 20478 Latent coding 3538 TOTALS 790 31294 24016 800 800 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. awnghlsoft Right-Suite RasIdentieP°5.0.11 R5R20780 2018Nov-1311:22:38 C:1My DocumentsIWang ofl HVAC\cL HEAT CALCS ar Page 1 1 r RIGHT-J BUILDING ANALYSIS REPORT • 15E- Entire House CLIMATROL HVAC DESIGNS Job:CL53DAILEY 11-14-2018 3170 MATECUMBE KEY ROAD UNIT 127,PUNTA GORDA,FL 33955 Phone:508-364-5198 Fax 941-575-0013 EmS:MILLERHVACDESIGNSCGMAILCOM Project Information For: MATT DAILEY HVAC . 147 BERRY AVE,WEST YARMOUTH, MA Design Information Htg Clg Infiltration Outside db(°F) 10 88 Method Simplified Inside db °F) 70 75 Construction quality Average Design ( F) 60 13 Fireplaces 0 Daily range - M Inside humidity(%) - 50 Moisture difference(gr/Ib) - 28 Heating Component Btuh/ft2 Btuh aha of load Walls 5.4 4147 14.8 Windows 33.1 5819 20.8 Doors 0.0 0 0.0 . Ceilings 2.9 2275 8.1 Floors 9.4 7394 26.4 I "i Infiltration 47.5 8359 29.9 Oliva Ducts 0 0.0 Total 27994 100.0 „Cooling Component Btuh/ft2 Btuh %of load w Walls 1.5 1147 5.4 Windows 56.2 9899 46.5 cans Doors 0.0 0 0.0 Ceilings 1.8 1403 6.6 14% Floors 0.0 0 0.0 w„°,.. Infiltration 4.3 755 3.5 Ducts 0 0.0 a Internal gains 8100 38.0 Calms Total 21304 100.0 Coding at 86%SHR=2.0 ton Cooling air flow=400 cfm/ton Coding at 70%SHR=2.4 ton Coding at 400 cfmlton=2.0 ton Overall U-Value=0.140 Btuh/ftt°F Data entries checked. wngIntsofit RightSuie Residential"'5.0.14 RSR20780 2018-Nov-13 11:22:36 C:\My Documents 1Wdghtsof HVAC\CL HEAT CALCS.mr Page 1 • eie RIGHT-J CALCULATION PROCEDURES A, B, C, D • VIII Entire House �' CLIMATROL HVAC DESIGNS Job:CL53DAILEY 11-14-2018 3170 MATECUMBE KEY ROAD UNIT 127,PUNTA GORDA,FL 33955 Phone:508-3545198 Fax 941-575-0013 Email:MILLERHVACDESIGNS@CMAILCOM Procedure A-Winter Infiltration HIM Calculation* 1. Winter infiltration AVF 1.2 ach x 6320 ft' x 0.0167 = 127 cfm 2. Winter infiltration load 1.1 x 127 cfm x 60 -F Winter TD = 8359 Btuh 3. Winter infiltration HTM 8359 Btuh / 176 ft' Total window = 47.5 Btuh/ft2 and door area Procedure B -Summer Infiltration HTM Calculation 1. Summer infiltration AVF 0.5 ach x 6320 ft' x 0.0167 = 53 cfm 2. Summer infiltration load 1.1 x53 cfm x 13 °F Summer TD = 755 Btuh 3. Summer infiltration HTM 755 Btuh / 176 ft2 Total window = 4.3 Btuh/ft' and door area Procedure C -Latent Infiltration Gain 0.68 x28 gr/Ib moist.diff. x 53 cfm = 990 Btuh Procedure D -Equipment Sizing Loads 1. Sensible sizing load Sensible ventilation load 1.1 x 50 cfm vent. x 13 °F Summer TD = 715 Btuh Sensible load for structure(Line 19) + 21304 Btuh Sum of ventilation and structure loads = 22019 Btuh Rating and temperature swing multiplier x 0.93 Equipment sizing load-sensible = 20478 Btuh 2. Latent sizing load Latent ventilation load 0.68 x 50 cfm vent. x 28 gr/Ib moist.diff. = 938 Btuh Internal loads = 230 Btuh x 7 people + 1610 Btuh Infiltration load from Procedure C + 990 Btuh Equipment sizing load- latent = 3538 Btuh 'Construction Quality is: a No.of Fireplaces is: 0 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wngl-rtsofit RightSuite ResldentiN'-5.0.14 RSR20750 2018-Nov-1311:22:35 Atak C:\My Documema\Wrightsoft HVAC\CL HEAT CALCS.rsr Page 1 rY ., £9Et0E6LOZ/13Z/80 SLEL /f N., i 'SELL-L£9Z0 VW:'a3lSM3a9 02!3'JQla 3NOIS£e4, A31VOOM3HliVW s 0310IY19321NO-a31SVW x y 3SN33FI ONIMO11OA 3141 S3fs$I S835aOM 1V13W 13314S • 3LifSN30I1 1VNOISS3JOad dO NOISIAIO .g SLL3S11HOVSSVW 40 HL1V3MNOWWOOM I • i2.._._.._. ._ - • t