Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDE-19-003092
\t Commonwealth of - Official Use Only or Massachusetts Permit No. BLDE-19-003092 7 w_e BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked 'Rev.I/071 APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT ININK OR TYPE ALL INFORMATION) Date:11/19/2018 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to pertomr the electrical work described below. Location(Street&Number) 7 COVEY DR Owner or Tenant SODERBERG DANA J Telephone No. Owner's Address SODERBERG LEANN E,7 COVEY DR,YARMOUTH PORT,MA 02675-2255 Is this permit in conjunction with a building permit? Yes ❑ No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead ❑ Undgrd ❑ No.of Meters New Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Solar installation. Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons _KW _ No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired.or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: CORY J WALKER Licensee: CORY J WALKER Signature LIC.NO.: 54207 (If applicable,enter"exempt"in the license number line) Bus.Tel.No.: Address: 110 Sheffield Rd, Brewster MA 026312860 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner ❑ owner's agent. Owner/Agent Signature 9 (4.0 Telephones No. PERMIT FEE:$150.00 q/W uJY fl s,i'l 61/70!/e r�`t e /� 3 t. nnowon&oi7Y/assac lis Use d9 e `lig r= 2eparimeni of as Services Permit No. 1:I= ' Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS 1/0 • • (leave blank) riQ APPLICATION FOR.PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00(PLEASE PRINT mINK OR TYPE ALL INFORM/1770N Date: 1\I lcil ji City or Town of: YARMOUTH To the Inspector of Wires: : this application the undersigned givesnnotice of his or her intention to perform the electrical work described below. 0 d ation (Street&Number) 7 eriltU , W m '+nerorTenant ��er5 J Telephone No. N r.I.er's Address ________ — • ,$s is permit in conjunction with a building permit? Yes ® No Lu n0 (Check Appropriate Box) 'U 1?; i u, ,ose of Building }Z2sjcyt C.2 Utility Authorization No. (� $ ting Service_ Amps / Volts Overhead ❑ Undgrd❑ No.of Meters _ INe Service 0 Undgrd_ Amps / Volts Overheadgr ❑ No.of Meters -Nurdber of Feeders and Ampacity -- • Location and Nature of Proposed Electrical Work So for let S\-AAA Completion of the folknvintiable may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Cet7rSusp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlet No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above In- No,of Emergency Lighting end. 0 prod. 0 BatteryUnitr No.of Receptacle Outlets No.of OH Burners FIRE ALARMS-INo.of Zones No.of Switches No.of Gas Burners No.of Detection and • Initiating Devices • No.of Ranges No.of Air Cond. Tons No.of Alerting Devices No.of Waste Disposers Heat Pump I Number (Tons IKW No.of Self-Contained - Totals: Detection/Alerting Devices No.of Dishwashers • SpaceArea Heating KW Local Municipal CP Connection 0 Otfie Qs/, No.of Dryers Heating Appliances Security Systems:' l"J No.of Water No.of Devices or Equivalent No.of No.of - J Heaters KW Signs Ballasts Data Wiring: No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications iW ng: No of Devices or Equivalent OTHER Attach additional detail f desired or as required by the Inspector of Wirer. Estimated Value of Electrical Work: a'S90 (When required by municipal policy.) S Work to Start IS 17 Inspections to be requested in accordance with MEC Rule 10,and upon completion, INSURANCE CO E GE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) I cernfy, under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: enrt TLn vtSb,r \earrerAJl Licensee: (t y tA '�) `� .f Signature —✓\ LIC.NO.• (j LIC NO.: (Ifapplicable,enter 'setup["in the license number fine.) Address gBus.Tel.No. X74-71�. gp 5'7 •„i •Per M.G.L.c. 147,s.57-61,securitywork requiresAlt.Tel.No.:__ — OWNER'S INSURANCE WAIVE : I am athat Department does not have the liabilitycense: Lin.insurance coverage ' required bylaw. Bymysignature 0wa covers a normally q� below,I hereby waive this requirement. I am the(check one) owner 0 owner's agent r Owner/Agentg Signature• Telephone No. 1 PERMIT FEE: $ /SQ� 1 Four W FaY SA, 1 _ a (10) acBnnch(typ).rN .1..._ Mae ��Lik> One-Line Electrical Diagram Mk o-Envherters Enphase F3]+ re •u. ewe (10)Soler Modules Solana 320 I ems Goa an Factory Supplied Cabling Wen I I I gm Mk gramaltaosi etiMrMOSe S ItIo ••• Cill ra Oa Each Branch(twp) (10)Mkro-lnvarters Enphase K17+_s B (10) FactorySupplied Modules M 4blrl320 Inas rl: Vin I I I ilin raromatea cum ass Mt Ya-O-as Aso am NOM I.essYverrraryrYl Mt torY- /MC F•r••Mallaret rfrila Ind —INC MOM 9.•••Ni limi glagManew I---••i•roarva.M naI•Nsaratea.s.�•v ISMS bele At d Faa•A- aM-alb NO. 0— ro ^© '1 test MA M—. Soderberg ]Cagy Road,Yarmouth port,MA My Generation Energy 11/19/2013 Data Sheet Enphase Microinverters Region:APAC Enphase The high-powered smart grid-ready Enphase IQ 7 Micro"'and Enphase IQ 7+Micro IQ 7 and IQ 7+ '" achieve the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Micro integrate seamlessly with the Enphase Envoy-S"',and the Enphase Enlighten"' monitoring and analysis software. The IQ 7 and IQ 7+Micro extend the reliability standards set forth by previous generations and . undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty. Easy to Install . 1 • Lightweight and simple fff _ • Faster installation with improved,lighter two-wire cabling 3ls Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure )CN"NASE __ IQ Smart Grid Ready r y • Complies with advanced grid support,voltage and frequency y tnefar IF ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles •The 10 7+Micro is required to support 72-cell modules To learn more about Enphase offerings,visit enphase.com/au a EN PH AS E. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7.60-2-INT IQ7PLUS-72-2-INT Commonly used module pairings' 235W-350W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V•45V Operating range 16V-48V 16V-60V Min/Max start voltage 22V/48V 22V/60 V Max DC short circuit current(module lsc) 15 A 15 A Overvoltage class DC port II II DC portbackfeed under single fault OA OA PV arrayconfiguration AC sideprequiresn. >.. protection max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Mlcroinverter IQ 7+Microlnverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-N)voltage/range° 230 V/184-276 V 230 V/184-276 V Maximum continuous output current 1.04 A 1.26 A • Nominal frequency 50 Hz 50 Hz Extended frequency range 45.55 Hz 45.55 Hz Maximum units per 20 A(L-N)branch circuit 16(230 VAC) 13(230 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @230 V @230 V EN 50530(EU)weighted efficiency 96.5% 96.5% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type MC4(or Amphenol H4 UTX with additional Q-DCC•5 adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated Environmental category/UV exposure rating Outdoor-IP67 FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Compliance(pending) AS 4777.2,RCM,IEC/EN 61000-6-3, IEC/EN 62019-1,IEC/EN 62109.2 1.No enforced DC/AC ratio.See the compatibility calculator at httos//enohase com/en-us/sunonrt/module-romoatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. To learn more about Enphase offerings,visit enphase.com/au C 2018 Enphase Energy All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. C EN PHAS E. 2010.01-23 `/