Loading...
HomeMy WebLinkAboutEngineered Plans - 20180 ae 105 28.7 LP 2 'SX�E'SPT. 1TIC TANK )c) O O I ~ lLJ L P 29.2 1 DRIVEWAY 28 mil mo-m-m-mup., 5 13.0 T13M = EL. 30.9 TOP OF STEP 28.5 CV 28.9 0 C4 ICA o 28.8 C 10' LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— APPROX. WATER SERVICE 19 TEST PIT SCALE: 1 "=20' ? GN R0 gTEVEN �N• a oRUMBA NO.35791 �O �FGISN 1\- 1�4�% h Hen 0VZ._ Df tr i;,e Date WEST YARMOUTH 0 s 0 a r cn r� LOCUS OLD TOWNHOUSE ROAD CONSTANCE AVE. SHEFFIELD RD. l LOCUS MAP LOCUS INFORMATION TITLE REF: BK 29190/PG 109 PARCEL ID: MAP: 086 LOT: 262 FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 554 WEST YARMOUTH ROAD WEST YARMOUTH, MA PREPARED FOR ROBERT HERRERA/ READY ROOTER EXC. NOVEMBER 6, 2018 OF 44s� D N M. y N 14 4N �(I I � I I � MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5C9)gmail.com SHEET 1 OF 2 J##1894 i ELEV. TOP FOUNDATION (Existing) = 30.00 i-F.G.EL. 29.2 NOTE: PLACE MAGNETIC MARKING TAPE OVER ALL COVERS BRING ALL COVERS TO WITHIN 3' OF FINISH GRADE F.G.EL- 29.00 F.G. EL:- 29.0 4 ; � jl 0" I TEE'S ARE TO BE 14 is @:52 1 % 4" SCH 40 PVC INV.26.45 INV.26.70 INV. 26.95 1NV. EXISTING OUTLET BAFFLE PROPOSED DB-3 N DISTRIBUTION BOX am I (H20) EXIST. 1,000 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL, OR EQUAL NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK WITH 1500 GALLON SEPTIC TANK IF FAILED, DAMAGED, NOT H2O LOADING, OR UNDERSIZED. 4) INSTALL INLET & OUTLET TEES W/ GENERAL NOTES: 1- ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER 1S NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY/CERTIFIED PLOT PLAN 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING. 15. ALL PIPING TO BE 4' SCH 40 O 1/8%FT (UNLESS SPECIFIED) SEPTIC SYSTEM PROFILE SOIL LOGS FINISHED GRADE (28.80) MAINTAIN 2% MIN SLOPE OVER LEACHING AREA 2" OF 3/8" DOUBLE WASHED STONE OR FILTER FABRIC 4" SCH 40 PVC ,MIN.) 2 EFF. DEPTH 26.25 4' INV. ELEV.= 25.5 TOP CONC. ELEV.= 26.50 INV. ELEV.= 25.50_ BOTTOM EL.= 23 SEPARATION 5.70 FT. BOTTOM OF TESTHOLE EL: 17.80 DATE: OCTOBER 24, 2018 SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614 WITNESS: PHIL RENAUD, YARMOUTH HEALTH DEPT. Elev. TP- 1 Depth 28.80 A LOAMY SAND 0' 28.13 1OYR 3/2 8" B LOAMY SAND 10YR 5/8 26.13 32' C UM PERC ITT 2.5Y 6/4 O EL 24.47 17.80 132" PERC RATE <2 MIN/IN. (*Cl- HORIZON) NO GROUNDWATER OBSERVED • I, Darren M. Meyer, R.S., CSE, hereby certify that i am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct sal evaluation* and that the above analysis has been performed by me consistent with the requirement* of 310 CMR 15.017. 1 further certify that I have passed the Sal Eval. Exam in October, 1999. aaaaa altaaaa a®aaa 3X8.5' 3/4" - 1-1/2" DOUBLE WASHED 4' EFFECTIVE LENGTH = 33.5' BREAKOUT ELEV.= 26.5 as aaaa®86 aaaaaaa aaaaaaa 4' 5 FT. 4' EFFECTIVE WIDTH = 13' SOIL ABSORPTION SYSTEM (SECTION (500 GALLON LEACH CHAMBER) DESIGN CRITERIA NUMBER OF BEDROOMS: 4 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 4 BR = DESIGN FLOW: 440 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 440 gpd x 200% = 880 gpd USE EXIST. 1,OOOG SEPTIC TANK LEACHING AREA REQUIRED: (440)/0.74 - 594.59 S.F. USE THREE (3) 500 GALLON PRECAST LEACH CHAMBERS W/ 4' STONE ON ALL SIDES: 33.5' L x 13' W x 2'D BOTTOM AREA: 33.5 x 13= 435.5 SF SIDE AREA: (33.5 + 13) X 2 X 2 = 186 SF TOTAL SQUARE FEET PROVIDED = 621 vs. 594.59 REQ'D DESIGN FLOW PROVIDED: 0.74(621 S.F.) = 459.91 G.P.D. vs. 440 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 554 WEST YARMOUTH ROAD, W. YARMOUTH, MA Prepared for: Herrera R dy Rooter Exc. Design and Site Plan by: SCALE DRAWN DATE MEYER & SONS, INC. N.T.S. DMM 1 1 /06/18 PO BOX 981 REV DATE EASTSANDWICH, MA 02537 CHECKED SHEET NO. 5M,W2s22 DMM 2 of 2