Loading...
HomeMy WebLinkAboutEngineered Plans - 2018LOCUS (WHITE'S PATH LOCUS MAP NOT TO SCALE: 18-0123 0• 96.0 EXISTING 1,000 / GALLON SEPTIC TANK TO REMAIN / 24" OAK EXISTING LEACHING i °'� —� PIT TO BE PUMPED, CRUSHED AND cb1b 2685� 96 3 A=59.49, BENCHMARK TOP OF CONCRETE 100.00 PER PREVIOUS SITE PLAN SITE & SEWAGE REPAIR PLAN #10 BLUE ROCK ROAD IN S. YARMOUTH, MA DATE: NOV. 28, 2018 OWNER/APPLICANT: JONAH SHEA 10 BLUE ROCK ROAD SOUTH YARMOUTH 508-958-3927 SHEET 1 OF 2 REMOVED FROM LOCUS 4' 2O' p0 $� (12.0' D.T. H. #1 — — PROPOSED ---- LEACHING S.A.S. (2) CHAMBERS 13.0'x25.0' KITCHEN PLANTER ( DECK 30.0 2' mBED#3 I RAMP LIV.ROOM I BED#1 D.T.H #2 — — 97.7 I I EX. 22.8' i 3 IPEASTONE 27.0 97. — — I DRIVEWAY I I N 85' 10'00,, W I ------ 204.14' _ _ PAVED 13 97.9 — — — J L_ I PARKING I 102 98.1 LOT 12,340f S.F. TLI 0 N N co m to 41 N B—L----------x-------- BLUE ROCK ROAD BENCHMARK 97.6 F CATCH LOCUS DATA I — — — EL,EV TOP �TION 97.06 BASIN CURRENT OWNER ESTATE OF >-- JOSEPH M. SHEA LI () PLAN REFERENCE 41241—A ct� L d �►OF DEED REFERENCE CTF 166950 = ���'� Yarmouth Health Department U EDAARD P �D ZONING DISTRICT R-40 PREPARED BY: STONE ��- „ N . ss o ame Date ASSESSORS FLOOD ZONE x E A S SURVEY, INC. ASSESSORS MAP 110 P.O. BOX 1729 g ZewJ7- 4— -� PARCEL 43 SANDWICH, MA 02563 0 20 30 40 OVERLAY DISTRICT ZONE II LOT AREA 12,340f S.F. CELL (508) 527-3600 GRAPHIC SCALE: EAS.SURVEY@YAHOO.COM 1 INCH = 20 FEET OF FOUNDATION 99.5 INV.= INV.= EXISTING 94.68 JOB # 18-0123 FINISH GRADE ELEV. 96.3 10"TEE 14'TEE JJ INV.= INSTALL 94.51 GAS BAFFLE 4'-1" . LIQUID LEVEL 6" BASE OF CRUSHED STONE OR MECHANICALLY COMPACTED FILL 1,500 GALLON PRECAST CONCRETE SEPTIC TANK SITE & SEWAGE REPAIR PLAN #10 BLUE ROCK ROAD IN S. YARMOUTH, MA DATE: NOV. 28, 2018 OWNER/APPLICANT: JONAH SHEA 10 BLUE ROCK ROAD SOUTH YARMOUTH 508-958-3927 SHEET 2 OF 2 EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 CELL (508) 527-3600 EAS.SURVEY@YAHOO.COM COVERS TO WITHIN 6" OF FINISH GRADE ELEV. 96.5 46' ®S= 0.027 4" PVC SCH 40 ONE CHAMBER RISER I FINISH GRADE RAISE TO WITHIN 6" OF FINISH GRADE ELEV. 96.5 QRC /6" 3 OUTLET H-20 D63 TION 96.3 1' MIN.-3' MAX. COVER 8'OS=0.01 00000 0 0 00000 0 p o 0I 0 0 O 0 1� 000000 p o �000� TWO 5'-0"x8'-6"x3'-0" H-20 CHAMBERS ITV.=93.00 p L INV.= 93.08 aS.A.S. (13.0' x 25.0a91.00 STRIPOUT (23' x 35'� rn o ui uS 85.1 CONSTRUCTION NOTES: 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. ENGINEER TO VERIFY REMOVAL OF UNSUITABLE SOILS PRIOR TO INSTALLATION OF NEW SEPTIC SYSTEM. 4. NO PARKING OVER SEPTIC TANK IS ALLOWED. GENERAL NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 3" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS OTHERWISE SPECIFIED. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. 13. MAGNETIC TAPE ON ALL COMPONENTS. 00000 0 0 00000 IN o 000 -- 4.0' 5.0' ---� 4.0'--{ 13.0' - SIDE VIEW DATUM: VERTICAL DATUM: ASSUMED - PREVIOUS SITE PLAN BENCH MARK SET: CATCH BASIN RIM ELEVATION 97.06 DTH #1 ja INDICATES DEEP TEST HOLE SYSTEM DESIGN DESIGN FLOW 3 BEDROOMS AT110 GPB/D 53Q GPD REQUIRED SEPTIC TANK 330 x_2 _ 660 GAL. SEPTIC TANK PROVIDED = _ 1500 -GAL. SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC RATE __ 5- _--_MIN./INCH LONG TERM APPL. RATE-2•74_GPD/S.F. SIZE OF LEACHING SYSTEM PROVIDED: 330 + 0.74 SF/GPD = 446 S.F. MIN. REQ. USING H-20 CONCRETE LEACHING CHAMBERS WITH 4' OF STONE ALL AROUND BOTTOM (13.0' x 25.0') = 325 S.F. SIDE WALL (13.0' + 25.0') 2x2 = 152 S.F 477 S.F. �j 477 S.F.x 0.74 G/SF = 353 GPD 353 GPD PROV > 330 GPD REQ. = 23 GPD RES. NO (GARBAGE DISPOSAL / GRINDER ALLOWED) .00. 144" INDICATES ADJ. GROUNDWATER NO OBSERVED GROUNDWATER NO MOTTLING NO WEEPING GROUNDWATER ADJUSTMENT DEPTH TO BOTTOM OF HOLE 12.0' VARIANCES REQUESTED NONE: D.T.H. #1 ib DATE: 11 /10/88 GROUND ELEV. 97.1 ADJ G.WATER 85.1 TOP / SUBSOIL ELEV = 94.6 MEDIUM SAND NO G.WATER_144" _EV = 85.1 D.T.H. #2 0 DATE: 11 /10/88 GROUND ELEV. 95.9 ADJ G.WATER N/A TOP / SUBSOIL 30" ELEV = 93.4 MEDIUM SAND NO G.WATER I120" ELEV = 85.9 B.O.H. TERRY HAYES, BOH SOIL EVALUATOR TED DUMAS SOIL TYPE: 1_ PERC RATE: <2 MIN. PER INCH LOADING RATE: 0_74 GAL/SF/MIN