Loading...
HomeMy WebLinkAboutEngineered Plans - 2018LEGEND N Cap ain Lo roP R [[GGG��MLDD - 20 - - EXISTING CONTOUR11 BVW09 x 20,12 EXISTING SPOT GRADE nAL o 336—pG 61 0,00 ULL 100 PROPOSED CONTOUR LOCUS o, 3• o °na • ' �� 7.3 PROPOSED SPOT GRADE o ' o 0 t l s==JA^ Q R L 4 060, o �• ' BVW08 97,8 ,111� HEALTH DEPT. —W— —G— -01 �.2 %E--- EXISTING WATER SERVICE m `°• EXISTING GAS SERVICE ? o OVERHEAD WIRES w ;)aa co '� a 98.27 �.� -� -•� - ' -9$ - - BVW-2 WETLAND FLAG T o g captain Simmons Rd o. ' .x S 09,10936" E' ��. B9g 52 WETLAND SYMBOL 98.85 x 131 •08 LOT 13A •� •�• AL � TEST PIT wa BENCHMARK Sierra No es Rd BVW06 captain x 99.68 - -9_9_ _ - 10, -0 F 6�f7-41 �• 98,32 x 99.74 MAPID: LOCUS MAP l tea- SHR. x 99,54 PUMPOCHA \\ IBER 6 p• VEGETATED WETLAND --� NOT TO SCALE GENERAL NOTES: ��•��� ♦ 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL •� EXISTING AL ` BOARD OF HEALTH AND THE DESIGN ENGINEER. SPLIT LEVEL DECK WORK LIMIT/HAY WATTLE x 97,52 2• ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS HOUSE(#7) (above) Dc� (15V NOTE 15) GS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS EXCEPT AS REQUESTED BELOW: b T.O.F.=104.22 FF= i05..3t" i� 10' p �•` -310 CMR 15.405(1)(h): 1) A 1' reduction to the required 4' • separation between maximum 98•94 x BVW05 seasonal high groundwater and bottom of S.A.S., for 3' separation. k98.42 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR 100,50 ` 4 •�, �7° % o TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE `. iri x01,7 d, �0 �` �' ,� DESIGN ENGINEER. 1 2,6 '� �` ♦ 6+ 04', 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING EXISTING SEPTIC TANK •� w 02 �y r ` FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN TOP OF TANK, EL.=102.01 O I 84 I �y • ENGINEER BEFORE CONSTRUCTION CONTINUES. 100- "U Q + .29 —PRESERVE 98.68 ` o BVW04 5. ALL ELEVATIONS.ARE BASED ON AN ASSUMED DATUM.. ,::. � 9 •36 IT1. O � , I TREE 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF �:..'' THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF •t • .100.36; : ;,;'? ^ ." : tK ` x 98,09 HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. �. ` t.•-5ai-'' ID O 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. a. �• I I x j� �11s 8. THERE ARE NO ABUTTING WELLS WITHIN 100' OF THE PROPOSED S.A.S.. �•:; I I h 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS 100, 5 �; I ; AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE .,:.;.�•: ; : ; . DIRECTED BY THE APPROVING AUTHORITIES. G� • • y-'`t y`"�� p{3- - 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY EXISTING S.A.S. ` THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CBdh Z 3 , • TO BE REMOVED WITHIN CONSTRUCTION. 68.8 i STRIPOUT BOUNDARY, 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS `� OTHERWISE ABANDONED. IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND UTILITY 1 0,02 N0`'10'36" W 'tip 9'7499.68 � )3,VW03 REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). POLE o cr . 98,82 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE o 0 99,10. o _ INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 100,20 edge 99.64 of o� pavement o' 99.16 -� • �` OF 4S 13. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED EXISTING �L SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. BENCHMARK �` �� o ` 14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND J�R,4 J� /� �i o PETER T. J' IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. MAGNETIC NAIL SET BLYTH� T�1 L1 , (11 Mc CIVIL `�`, EL.=99.86 v CIVIL "' 15. EROSION CONTROL FOR ALL DISTURBED AREAS SHALL BE MAINTAINED o. 35109 BVW02 UNTIL STABILIZED WITH GRASS. HYDROSEEDING IS RECOMMENDED. PK SET 86 PROPOSED S.A.S. O FEMA FLOOD DESIGNATION '� PROPOSED SEPTIC SYSTEM UPGRADE PLAN NON HAZARD PARTIAL STRIPOUT TO SUITABLE � 7 BLYTHE TERRACE WEST YARMOUTH, MA "C" HORIZON MAY BE REQUIRED ,2 ��2 i Prepared for: Robert Pontz, 7 Blythe Terrace, West Yarmouth, MA 02673 WETLAND CONSULTANT INSTALL A 40 MIL POLY LINER PLAN REVISION 12/1218 OWNER OF RECORD Engineering by: SCALE DRAWN JOB. No. MARSH MATTERS ENVIRONMENTAL TOP OF LINER, EL.=101.0 PONTZ, ROBERT K En ineerin WOYI�.S, Inc. 1 "=20' P.T.M. 233-18 P.O. BOX 554 ADD WORK LIMIT, NOTE 15 AND Engineering FORESTDALE, MA 02644 BOTT. OF LINER, EL.=98.5 NOTE TO PRESEVRE TREE BSULLIVAN LYTHE TERRPONTACE DONNA K 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. 978-434-1228 WEST YARMOUH, MA 02673 (508 ) 4 77-5313 11/7/18 P.T.M. 1 of 3 EXISTING SEPTIC TANK & PROPOSED PUMP CHAMBER NOTE: TO PREVENT BREAKOUT, INSTALL A 40 MIL POLY LINER AS SHOWN ON SHEET 1. PROVIDE RISERS & COVERS AS DESCRIBED: TOP OF LINER, EL.=101.0 1) INLET COVER SET TO 6" OF GRADE. PROPOSED D-B BOTT. OF LINER, EL.=98.5 2) 20" OUTLET COVER SET TO GRADE QX MANHOLE COVER SHALL BE SECURED INSTALL WATERTIGHT RISER & PROPOSED S.A.S. TO PREVENT UNAUTHORIZED ACCESS. COVER SET TO 6" OF GRADE INSTALL ONE INSPECTION, (MINIMUM) `F.G. EL.=102.4t F.G. EL: 102.4f F.G. EL.=101'.7(MIN.) to 102.1t F.G. EL.=102.5(EXISTING) / PROVIDE ENOUGH WIRE SLACK TO REMOVE PUMP MAINTAIN 27 GRADE (MIN.) OVER S.A.S. /// •� ®�� L - 22'f ®S=1% (MIN.) VC4"SCH40 P s" 14" 10" ADD EFFLUENT INV.=100.70 2 FLOATS FILTER USE OUTLET ,......_.. KNOCK OUT EXISTING SEPTIC TANK nvV.= I UU. iys EXISTING (FIELD VERIFY) 1000 GALLON PUMP CHAMBER (H-10 RATED) (See Pump Detail, Sheet 3) QMN L=10'(MAX) 2° HAID 1 B ocKs 4"SCH40 PVC PROVE pS p�L BENDS 1--� 6 EFF.DEPTH I NV. =100.' INV.=100.90 PROPOSED D-BOX 3 OUTLETS (MIN.) INV.=100.45t INV.=100.61 -� NOTES: 1) PUMP CHAMBER & D-BOX SHALL BE SET LEVEL AND TRUE ELEV.=100.96 BREAKOUT TO GRADE ON A MECHANICALLY COMPACTED 6" CRUSHED BREEKOUT .85(END) - STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 2) INSTALL INLET & OUTLET TEES AS REQUIRED. BOTTOM ELEV.=100.00 3) MAX. COVER OVER SEPTIC TANK, D-BOX & S.A.S. SHALL BE 36". 4) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR 4' MIN. SEPARATION G.W. TO CONSTRUCTION. AND OF NATURALLY 5) EFFLUENT FILTER SHALL BE INSTALLED ON OUTLET OCCURRING PERVIOUS SOILS TEE AS MANUFACTURED BY ZABEL OR EQUAL. FILTER EST. HIGH G.W. EL: 96.0 SHALL BE INSPECTED AND CLEANED ANNUALLY. SEPTIC SYSTEM PROFILE DESIGN CRITERIA NUMBER OF BEDROOMS: 3 SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF .74 GPD/SF EXISTING SEPTIC TANK: 1000 GALLON CAPACITY PROPOSED PUMP CHAMBER: 1000 GALLON CAPACITY, H-10 PROPOSED D-BOX: 1 INLET, 3 OUTLET (MIN.), H-10 INSTALL AN 20' x 22.6' LEACH FIELD SIDEWALL AREA: NOT APPLICABLE BOTTOM AREA: 20' x 22.6' = 452.0 S.F. TOTAL AREA: ....................................... 452.0 S.F. LEACHING CAPACITY = 0.74 GPD/SF x 452.0 SF = 334.5 GPD DIAM. INSPECTION PORT, 20' x 22.6 LEACHING FIELDfH4" PERFORATED IN S,A.S., SOLID JTH 3 DISTRIBUTION LINESABOVE S.A.S., WITH^SCREW CAP CAPPED ENDS TI SLOPE OF PERF. PIPE = 0.5% -INV. EL.=100.50(END) 22.6' EFFECTIVE LENGTH SOIL ABSORPTION SYSTEM (PROF, ) ESTABLISH VEGETATIVE COVER FINISH GRADE .=101.8 to 102.1 APPROVED FILTER FABRIC 3/4"-1 1/2" DOUBLE 6 6 4' WASHED STONE 20' EFFECTIVE WIDTH SOIL ABSORPTION SYSTEM (SECTION) SOIL LOG DATE: AUGUST 22, 2018 SOIL EVALUATOR: PETER McENTEE SE#1542 WITNESS: AMY VON HONE RS HEALTH AGENT ELEV. TP— 1 DEPTH 101.0 0" FILL (LOAM) 96.3 B LOAMY SAND 10YR 5/6 96.0 HIGH G.W. REDOX 7.5 YR 5/8 95.5 C MED. SAND 2.5Y 6/6 94.8 STDG. G.W. 56" 60" PERC 54"/66" 66" 74" 93.0 96" PERC RATE: <2 MIN./IN.("B"&"C" HORIZONS) ESTIMATED HIGH GW, EL.=96.0 PROPOSED S.A.S. 21.1'__� O+� Zp. S.A.S. DIMENSIONS SPLIT LEVEL jDECK HOUSE'(#(above) 7) T. 0. F.=104.22 IFF=106. 3f N •sue `—, � PROP. S.A.S. S.A.S. LAYOUT PROPOSED SEPTIC SYSTEM UPGRADE PLAN 7 BLYTHE TERRACE, WEST YARMOUTH, MA Prepared for: Robert Pontz, 7 Blythe Terrace, West Yarmouth, MA 02673 Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. N.T.S. P.T.M. 233-18 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 11/7/18 P.T.M. 2 Of 3 6 PROVIDE WATERTIGHT CONCRETE RISER WITH SECURED FRAME & COVER TO GRADE HOISTING CABLE 709 STAINLESS STEEL 1/8 DIAMETER. / 1,760 LB. STRENGTH. PROVIDE ENOUGH WIRE �— SLACK TO REMOVE PUMP T INV. (IN)=100.70 ALARM ON EL: 97.70 PUMP ON EL: 97.45 NEMA 4 JUNCTION BOX CORROSION RESISTANT & LIQUID —TIGHT CABLE CONNECTORS SUPPORTED BY 1-1/4" PVC CONDUIT. JOINTS TO BE MADE WATERTIGHT. USE SJE RHOMBUS—JB PLUGGER OR EQUAL. PROVIDE ENOUGH WIRE SLACK TO REMOVE PUMP �— INSTALL 1' PVC CONDUIT TO HOUSE FOR WIRING WITH WATERTIGHT JOINTS. WIRE HIGH' WATER ALARM FLOAT TO SJE RHOMBUS TANK ALERT XT ALARM PANEL ON CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. — 2" BALL VALVE (FIELD ADJUST FOR 20 GPM RATE) (INSTALL QUICK DISCONNECT FOR EASY REMOVAL) 2"SCH. 40 DISCHARGE 2" 90' ELBOW W/ 1 /4" WEEP HOLE PUMP OFF EL: 97.12 15" BOTTOM " 2" SWING CHECK VALVE PUMP CHAMBER 12MBER ELEV.= 96.12 —_ 2" SCH. 40 PVC DISCHARGE PIPE PROVIDE 2 FLOATS: 4" FLOAT NOA: PUMP ON/OFF—SJ RHOMBUS (PROVIDED WITH PUMP) FLOAT NO.2: ALARM ACTIVATION FLOAT —PROVIDED WITH ALARM PANEL LIBERTY LE40 SERIES PUMP .4 H.P. 115 V (ON SEPARATE CIRCUIT FROM PUMP SPECIFIED) WITH 2" DISCHARGE, OR EQUAL PUMP AND ACCESSORIES AVAILABLE AT: CAPE COD WINWATER WORKS CO., HYANNIS, MA. (508) 862-0166 NOTE: APPROVED ALTERNATE MAY BE SUBSTITUTED. PUMP DETAIL BEDROOM BATH KITCHEN DINING ROOM DECK HALL (above) —]� BEDROOM I BATH UP RIVIN GOOM I FL UPPER LEVEL GARAGE FLOOR PLAN - BEDROOM HALL 1DNI7 BATH FAMILY ROOM LOWER LEVEL DOSING & STORAGE REQUIREMENTS DESIGN FLOW: 330 GPD DOSING REQUIRED: 4 CYCLES/DAY (SAND) 330 - 4 = 82.5 GALLONS/CYCLE DISTANCE REQUIRED BETWEEN PUMP ON AND PUMP OFF FLOATS: 82.5 GAL/CYCLE - 250 GAL/FT = 0.33 FT/CYCLE (SAY 4") STORAGE REQUIRED ABOVE WORKING LEVEL: 330 GALLONS STORAGE PROVIDED: INV.(IN) EL: 100.70 — PUMP ON EL: 97.45 = 3.25' STORAGE PROVIDED = 3.25 x 250 GAL/FT = 812.5 GALLONS BUOYANCY CALCULATIONS NOT REQUIRED -BOTTOM IS ABOVE GROUNDWATER PROPOSED SEPTIC SYSTEM UPGRADE PLAN 7 BLYTHE TERRACE, WEST YARMOUTH, MA Prepared for: Robert Pontz, 7 Blythe Terrace, West Yarmouth, MA 02673 Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. N.T.S. P.T.M. 233-18 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 1 1 /7/18 P.T.M. 3 Of 3