Loading...
HomeMy WebLinkAboutEngineered Plan - 2018TOP FOUND. EL. 22.4 SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE MINIMUM .75' OF COVFR OVFR pRFCAST ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE r_ PRECAST H-10 NOTE: 2" MIN. WALL BLOCKS OR RISERS (TYP.) THICKNESS REQUIRED PRECAST RISERS 2'4 4"OSCH40 PVC MORTAR ALL H-10 6" MIN. SUMP PIPES LEVEL 1 ST 2' COMPONENTS INV'S EL. 18.0 12" MIN. INT. DIM.ENDS (NP') SIDES 18.83' a ai 10" EXISTING 14" '. ° O >°o°o°o°o TEE SEPTIC TANK TEE - a000 ooao aooa—o �ooa ° ° ° ° EXISTING aoaoaoaaaa❑ oa®oo�®oo�� 19.6t o0000000000 00 00 00 °°°°°°°°°°�° WATERTEST D'BOX ° ° ° ° 00000000 °o°o° °o°o ;°o°o°o°o aoaaoaaooao mooaoa®ocloo GAS BAFFLE ::' �_o�°�° ° °_ FOR LEVELNESS c� >gog00008 �aaOa�OL1mmm mDmmOKI0M�0E '00000000 18.27' 18.1 >°°°° ° 16.0 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. H-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. ALL AROUND PRECAST STRUCTURES {2) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00, X 1'2.83' COMPACTION. (15.221 [2]) (2.5 % SLOPE) (1 % SLOPE) • 10.0' BOTTOM TH-1 LEACHING NO GROUNDWATER FOUND FOUNDATION —EXISTING SEPTIC TANK 14D' BOX 12' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND 99 — EXISTING CONTOUR X 99. 1 EXIST. SPOT ELEV. —[99]— PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH 1 TEST HOLE 2�. SLOPE OF GROUND UTILITY POLE rX - FIRE HYDRANT- NOTE- NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: PHIL RENAUD DATE: 10/4/ 18 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 p°° 20.5' S 1OYR 4/2 18' B LS 36" 1OYR 6/8 17.5' PERC C MS 2.5Y 7/3 126" I ( 10' NO GROUNDWATER ENCOUNTERED LICE #18-341 FACILITY **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE —USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE Scale: 1 "= 20' 0 10 20 30 40 50 FEET 11 NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST F \ \ UNITS TO BE AASHO H-10 0� \ \} 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE L WITH 3 c 10 CMR 15.000 TITLE 5. ( ) Locus 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY 40� OTHER PURPOSE. �Qr ornin s40 � 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. ow t 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF to HEALTH AND PERMISSION OBTAINED FROM BOARD R OF HEALTH. 10. CALLINGTD GSAOR SHALL FE (1-8886 344E 720NSIBLE 33) AND LOCUS LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & l! OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1 "=2000'f WORK. ASSESSORS MAP 49 PARCEL 192 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE LOCUS IS WITHIN FEMA FLOOD ZONE X PROPOSED LEACHING FACILITY. (AREA OF MINIMAL FLOOD HAZARD) AS 12. EXISTING LEACHING FACILITY SHALL BE PUMPED SHOWN ON COMMUNITY PANEL #25001 CO587J AND REMOVED OR PUMPED AND FILLED WITH CLEAN DATED 7/16/2014 SAND. BULKHEAD BED z ROOM BATH DINING Y ROOM GARAGE BED LIVING ROOM - ROOM t0 -a-kb, DATE FLOOR PLAN NOT TO SCALE —Date OCT,2 b 1018 HEALTH DEPT. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 2 BEDROOM DWELLING DESIGN FLOW: 2 BEDROOMS @ 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 **RE —USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 2 MERGANSER LANE WEST YARMOUTH. MA PREPARED FOR MELISSA PETERSON A� ysi �` j�HSs c of t.1ss h DATE: OCTOBER 12, 2018 9c DF1.!IL ��' �ciy�AS%�SH 0 PAq" L Esm\ cf j`DANIELA. `� S OI,�� �'y« off 508-362-4541 s OJALA �!'Y CIVIL un' DANIE._ A v fax 508-362-9880 OJPD� 3 0 :� 'N No 40980 ;4 ; ,,;;�. 46502 � � - �IVit � i '�� downcape.com v Q C I.i^ /tL;S No. 46502 t y Fss\ STEP �0 I1 CdpO e/1�'//1L0Cf1#74 f /ITC. ss, i s e� ,G s� civil engineers oNAl- land surveyors 939 Main Street ( Rte 6A) DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 18-341 BASE.DWG